IEI Technology IOVU-430M User Manual Download Page 12

 

 

IOVU-430M Panel PC 

Page 5

1.6 Dimensions 

The physical dimensions of the IOVU-430M are shown in 

Figure 1-4

 and listed below: 

ƒ

 Width: 

145 

mm 

ƒ

 Height: 

104 

mm 

ƒ

 Depth: 

34 

mm 

 

Figure 1-4: IOVU-430M Physical Dimensions (millimeters) 

Summary of Contents for IOVU-430M

Page 1: ... i IEI Technology Corp User Manual MODEL IOVU 430M Panel PC 4 3 Touch Screen 416 MHz Marvell XScale PXA270 Fast Ethernet USB Mini SD CAN bus RS 232 422 485 RoHS Compliant Front Panel IP 65 Protection Rev 1 01 6 December 2010 ...

Page 2: ...IOVU 430M Panel PC Page ii Revision Date Version Changes 6 December 2010 1 01 Modified system mounting method 17 September 2010 1 00 Initial release ...

Page 3: ... arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of the manufacturer TRADEMARKS All registered tradem...

Page 4: ... PRECAUTIONS 10 2 2 UNPACKING PRECAUTIONS 10 2 3 UNPACKING CHECKLIST 11 2 4 OPTIONAL ITEMS 11 3 INSTALLATION 12 3 1 INSTALLATION PRECAUTIONS 13 3 2 MINI SD CARD INSTALLATION 13 3 3 EXTERNAL PERIPHERAL INTERFACE CONNECTORS 14 3 3 1 12 V 36 V DC Terminal Block 15 3 3 2 GPIO and CAN bus Connector 15 3 3 3 RS 232 422 485 Serial Port 16 3 3 3 1 Connecting the Serial Port 16 3 3 3 2 RS 232 422 485 Selec...

Page 5: ...FETY PRECAUTIONS 29 B 1 1 General Safety Precautions 29 B 1 2 Anti static Precautions 30 B 2 MAINTENANCE AND CLEANING PRECAUTIONS 30 B 2 1 Maintenance and Cleaning 30 B 2 2 Cleaning Tools 31 B 3 FCC PRECAUTIONS 32 C HAZARDOUS MATERIALS DISCLOSURE 33 C 1 HAZARDOUS MATERIALS DISCLOSURE TABLE FOR IPB PRODUCTS CERTIFIED AS ROHS COMPLIANT UNDER 2002 95 EC WITHOUT MERCURY 34 ...

Page 6: ... Figure 3 2 IOVU 430M Peripheral Connectors 14 Figure 3 3 Power Terminal Block 15 Figure 3 4 GPIO and CAN Bus Terminal Block 16 Figure 3 5 Serial Device Connector 17 Figure 3 6 COM1 mode setting 17 Figure 3 7 Serial Port Pinouts 18 Figure 3 8 USB Connector 19 Figure 3 9 LAN Connection 20 Figure 3 10 Ethernet Connector 21 Figure 3 11 Chassis Support Screws 22 Figure 3 12 In wall Cage Screw Holes 22...

Page 7: ...Package List Contents 11 Table 2 2 Optional Items 11 Table 3 1 External Interface Connectors 14 Table 3 2 12 36 V Power Connector Pinouts 15 Table 3 3 GPIO and CAN Bus Connector Pinouts 16 Table 3 4 RS 232 Pinouts 18 Table 3 5 USB Connector Pinouts 19 Table 3 6 Ethernet Connector Pinouts 20 Table 3 7 Ethernet Connector LEDs 21 ...

Page 8: ...IOVU 430M Panel PC Page 1 Chapter 1 1 Introduction ...

Page 9: ...ly low power Panel PC The system is fanless which allows quiet and reliable operation Connection to a variety of peripheral devices and networks is provided through a USB port a RS 232 422 485 serial port and an Ethernet port A CAN Controller Area Network bus connection allows the IOVU 430M to be used in a wide range of automotive and industrial settings 1 2 Benefits Some of the IOVU 430M benefits...

Page 10: ... processor 128 MB of SDRAM One Fast Ethernet port One USB 1 1 port One RS 232 422 485 serial communication connection One GPIO and CAN bus connection Projected capacitor multi touch panel or 4 wire resistive single touch panel 12 36 VDC input RoHS compliant 1 4 Front Panel The IOVU 430M front panel Figure 1 2 comprises a 4 3 TFT WQVGA color touch screen LCD in an ABS PC plastic frame Figure 1 2 Fr...

Page 11: ...IOVU 430M The peripheral interface connectors are shown in Figure 1 3 Figure 1 3 IOVU 430M Peripheral Connectors External peripheral interface connectors on the IOVU 430M include 1 x CAN bus connector 1 x DC IN terminal block 1 x GPIO connector 1 x RJ 45 LAN connector 1 x RS 232 422 485 connector 1 x mini SD card slot 1 x USB 1 1 connector ...

Page 12: ...30M Panel PC Page 5 1 6 Dimensions The physical dimensions of the IOVU 430M are shown in Figure 1 4 and listed below Width 145 mm Height 104 mm Depth 34 mm Figure 1 4 IOVU 430M Physical Dimensions millimeters ...

Page 13: ...cording to the instructions The IOVU 430M has a terminal block connector on the bottom panel 1 8 Model Variations The IOVU 430M is available in the following model variations Model No Touch Panel Type Wi Fi IOVU 430M CE5 MT R10 Projected capacitor multi touch No IOVU 430M CE5 MT WL R10 Projected capacitor multi touch 802 11b g IOVU 430M CE5 ST R10 4 wired resistive single touch No IOVU 430M CE5 ST...

Page 14: ...splay Display Type TFT LCD screen Display Size 4 3 Resolution 480 x 272 262 000 colors Video Support MPEG1 Brightness 400 cd m2 Backlight MTBF 10 000 hrs Pixel Pitch mm 0 066 H x 0 198 V Viewing Angle H V 100 60 Touch Panel Projected capacitor multi touch IOVU 430M CE5 MT RT10 4 wired resistive single touch IOVU 430M CE5 ST RT10 I O and Communications Ethernet 1 x 10 100 Mb s CAN bus 1 x 3 pin ter...

Page 15: ...3 1 Axes 3 axes Vertical Transverse Longitudinal 2 10 500 Hz 60min axis 3 Equivalent to Z 2 18 Grms X 1 6 Grms Y 1 96 Grms Front Panel Color Pantone Black C Physical Dimensions 145 mm x 104 mm x 34 mm Net Weight 0 7 kg Ingress Protection IP 65 compliant front panel Table 1 2 Technical Specifications 1 10 Certifications All IOVU 430M series models comply with the following international standards R...

Page 16: ...IOVU 430M Panel PC Page 9 Chapter 2 2 Unpacking ...

Page 17: ...ristband Wearing a simple anti static wristband can help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any conducting materials that are connected to the ground Use an anti static pad When configuring the IOVU 430M place it on an antic static pad This reduces the possibili...

Page 18: ...ly To contact an IEI sales representative please send an email to sales iei com tw The IOVU 430M is shipped with the following components Quantity Item and Part Number Image 1 IOVU 430M 1 Utility CD including SDK utilities and technical documentation 1 Null modem cable 1 Touch pen Table 2 1 Package List Contents 2 4 Optional Items Item and Part Number Image 12V DC 60W power adapter with terminal b...

Page 19: ...IOVU 430M Panel PC Page 12 Chapter 3 3 Installation ...

Page 20: ...is still connected to an electrical outlet Qualified Personnel The IOVU 430M must be installed and operated only by trained and qualified personnel Maintenance upgrades or repairs may only be carried out by qualified personnel who are familiar with the associated dangers Grounding The IOVU 430M should be properly grounded The voltage feeds must not be overloaded Adjust the cabling and provide exte...

Page 21: ... descriptions of the connectors can be found following the table Connector Type 12 36 V DC terminal block Terminal Block CAN bus CAN bus connector Ethernet connectors RJ 45 Jack connector RS 232 422 485 Serial connector D sub 9 Male connector USB connectors USB port Table 3 1 External Interface Connectors Figure 3 2 IOVU 430M Peripheral Connectors ...

Page 22: ... DC Power in 2 GND Table 3 2 12 36 V Power Connector Pinouts Figure 3 3 Power Terminal Block 3 3 2 GPIO and CAN bus Connector The IOVU 430M has a GPIO pins 1 7 and CAN bus connector pins 8 10 The GPIO can be used to connect to external devices or peripherals The CAN bus connector connects to a Controller Area Network CAN A CAN allows microcontrollers and devices to communicate with each other with...

Page 23: ...ort This section outlines the usage and setup of the serial port on the bottom I O panel 3 3 3 1 Connecting the Serial Port The IOVU 430M has one female DB 9 connector on the external peripheral interface panel for connections to serial devices Follow the steps below to connect a serial device to the IOVU 430M Step 1 Insert the serial connector Insert the DB 9 connector of a serial device into the...

Page 24: ...ention screws on either side of the connector Step 0 3 3 3 2 RS 232 422 485 Selection To select RS 232 422 485 mode please follow the directions below Step 1 Find and start the IEI CE_UTILITY Select the Windows CE Start menu next select Programs then select IEI and finally select IEI_CEUTILITY Start Programs IEI IEI CEUTILITY to launch the utility Figure 3 6 COM1 mode setting ...

Page 25: ...tton Click the Set button to apply the mode setting change Step 4 Click the Save Registry button Click the Save Registry button to save the settings Step 0 3 3 3 3 Pinouts Pinouts for the RS 232 422 485 serial port is shown below Pin RS 232 RS 422 RS 485 1 DCD RX DATA 2 RX RX DATA 3 TX TX 4 DTR 5 GND GND GND 6 DSR 7 RTS TX 8 CTS 9 RI Table 3 4 RS 232 Pinouts Figure 3 7 Serial Port Pinouts ...

Page 26: ...ries A receptacle on the external peripheral interface See Figure 3 8 Figure 3 8 USB Connector USB devices connect directly to the USB connector on the external peripheral connector panel PIN DESCRIPTION PIN DESCRIPTION 1 VCC 5 VCC 2 D1 6 D2 3 D1 7 D2 4 GND 8 GND Table 3 5 USB Connector Pinouts 3 3 5 Ethernet Connector There is one external RJ 45 LAN connector The RJ 45 connectors enable connectio...

Page 27: ...M See Figure 3 9 Figure 3 9 LAN Connection Step 2 Insert the LAN cable RJ 45 connector Once aligned gently insert the LAN cable RJ 45 connector into the on board RJ 45 connector Step 0 The Ethernet connector pinouts are shown below PIN DESCRIPTION 1 TPT 2 TPT 3 TPR 4 LAN_GND 5 LAN_GND 6 TPR 7 LAN_GND 8 LAN_GND Table 3 6 Ethernet Connector Pinouts ...

Page 28: ...ng WARNING When mounting the flat panel PC it is better to have more than one person to help with the installation to make sure the panel PC does not fall down and get damaged The mounting holes in the rear panel of the IOVU 430M are not Video Electronics Standards Association VESA compliant IEI provides an in wall cage to mount the IOVU 430M into a wall To mount the IOVU 430M in a wall please fol...

Page 29: ...e screw holes Figure 3 12 on in wall cage Figure 3 12 In wall Cage Screw Holes Step 3 Carefully insert the screws through the holes and gently pull the monitor downwards until the monitor rests securely in the slotted holes Ensure that all four of the mounting screws fit snuggly into their respective slotted holes Figure 3 13 Step 0 ...

Page 30: ...kage BSP for customers to customize their own OS image Attached Software Development Kit SDK for embedded Visual C to program Windows CE application Built in NET Compact Framework support with related SDK Thin Client Technology Microsoft RDP Remote Desktop Protocol to enable IOVU 430M to access Microsoft Windows based applications installed on Microsoft Terminal Service server Free pre installed u...

Page 31: ... around as shown below Figure 3 132 Figure 3 12 Wireless AP Step 2 Select your Internet connection and click Connect Step 3 The Wireless Network Properties screen appears next Figure 3 133 Figure 3 13 Wireless Network Properties ...

Page 32: ...t AP configuration is finished Figure 3 134 Figure 3 14 Wireless AP Connected Step 5 Click the IP Information button to view the information of the Wireless AP Solo If the server function is enabled on the AP You can automatically get the IP address subnet mask Figure 3 135 Figure 3 15 IP Information ...

Page 33: ...IOVU 430M Panel PC Page 26 Appendix A A Certifications ...

Page 34: ... Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead cadmium mercury hexavalent chromium polybrominated biphenyl PBB and polybrominated diphenyl ether PBDE flame retardants A 2 IP 65 Compliant Front Panel The front panel on the IOVU 430M models in the IOVU series have an ingress protection rating IP of 65 IP 65 The front...

Page 35: ...IOVU 430M Panel PC Page 28 Appendix B B Safety Precautions ...

Page 36: ...alled moved or modified Do not apply voltage levels that exceed the specified voltage range Doing so may cause fire and or an electrical shock Electric shocks can occur if the IOVU 430M chassis is opened when the IOVU 430M is running Do not drop or insert any objects into the ventilation openings of the IOVU 430M If considerable amounts of dust water or fluids enter the IOVU 430M turn off the powe...

Page 37: ...any electrical component touch any grounded conducting material During the time the electrical component is handled frequently touch any conducting materials that are connected to the ground Use an anti static pad When configuring or working with an electrical component place it on an antic static pad This reduces the possibility of ESD damage Only handle the edges of the electrical component When...

Page 38: ...citly mentioned in the cleaning tips Below is a list of items to use when cleaning the IOVU 430M Cloth Although paper towels or tissues can be used a soft clean piece of cloth is recommended when cleaning the IOVU 430M Water or rubbing alcohol A cloth moistened with water or rubbing alcohol can be used to clean the IOVU 430M Using solvents The use of solvents is not recommended when cleaning the I...

Page 39: ... more of the following measures z Reorient or relocate the receiving antenna z Increase the separation between the equipment and receiver z Connect the equipment into an outlet on a circuit different from that to which the receiver is connected z Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsibl...

Page 40: ...IOVU 430M Panel PC Page 33 Appendix C C Hazardous Materials Disclosure ...

Page 41: ...resences of small quantities of certain materials in the product and is applicable to China RoHS only A label will be placed on each product to indicate the estimated Environmentally Friendly Use Period EFUP This is an estimate of the number of years that these substances would not leak out or undergo abrupt change This product may contain replaceable sub assemblies components which have a shorter...

Page 42: ... Board X O O O O X Metal Fasteners X O O O O O Cable Assembly X O O O O X Fan Assembly X O O O O X Power Supply Assemblies X O O O O X Battery O O O O O O O This toxic or hazardous substance is contained in all of the homogeneous materials for the part is below the limit requirement in SJ T11363 2006 X This toxic or hazardous substance is contained in at least one of the homogeneous materials for ...

Page 43: ...较短的环境友好使用期限的可替换元件 像是电池或灯管 这些元 件将会单独标示出来 有毒有害物质或元素 部件名称 铅 Pb 汞 Hg 镉 Cd 六价铬 CR VI 多溴联苯 PBB 多溴二苯 醚 PBDE 壳体 X O O O O X 显示 X O O O O X 印刷电路板 X O O O O X 金属螺帽 X O O O O O 电缆组装 X O O O O X 风扇组装 X O O O O X 电力供应组装 X O O O O X 电池 O O O O O O O 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ T11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量要求 ...