gKINO-V/R1000 SBC
Page 106
NOTE:
The Watchdog Timer is activated through software. The software
application that activates the Watchdog Timer must also deactivate it
when closed. If the Watchdog Timer is not deactivated, the system will
automatically restart after the Timer has finished its countdown.
EXAMPLE PROGRAM:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
;
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT
15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE
W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV
BL, 0
;
INT
15H
;
; EXIT ;
Summary of Contents for gKINO-R1000 Series
Page 2: ...gKINO V R1000 SBC Page II Revision Date Version Changes September 1 2020 1 00 Initial release ...
Page 14: ......
Page 15: ...gKINO V R1000 SBC Page 1 Chapter 1 1 Introduction ...
Page 20: ...gKINO V R1000 SBC Page 6 Figure 1 4 gKINO R1000 Dimensions mm ...
Page 25: ...gKINO V R1000 SBC Page 11 Chapter 2 2 Unpacking ...
Page 29: ...gKINO V R1000 SBC Page 15 Chapter 3 3 Connectors ...
Page 64: ...gKINO V R1000 SBC Page 50 Chapter 4 4 Installation ...
Page 75: ...gKINO V R1000 SBC Page 61 Chapter 5 5 BIOS ...
Page 108: ...gKINO V R1000 SBC Page 94 Appendix A A Regulatory Compliance ...
Page 110: ...gKINO V R1000 SBC Page 96 B Product Disposal Appendix B ...
Page 112: ...gKINO V R1000 SBC Page 98 Appendix C C BIOS Menu Options ...
Page 115: ...gKINO V R1000 SBC Page 101 Appendix D D Digital I O Interface ...
Page 118: ...gKINO V R1000 SBC Page 104 Appendix E E Watchdog Timer ...
Page 121: ...gKINO V R1000 SBC Page 107 Appendix F F Error Beep Code ...
Page 123: ...gKINO V R1000 SBC Page 109 Appendix G G Hazardous Materials Disclosure ...