NOTE

: The default IP address of an eMerge Enterprise is 192.168.0.250. If you changed this 

in previous steps then enter the new address here. 

4.  At the Login page enter the 

User name

 “admin.” 

5.  Enter the 

Password

 “admin.” 

6.  Click 

Go

. The security application will now display. 

7.  Select 

Setup : System Maintenance : Restore System

8.  Click the link provided to upload the backup you previously made. Browse to the location of 

the system backup file and click 

Save

. The backup should now appear on the 

Restore 

System

 page. 

9.  Click the button in the 

Restore?

 column next to the backup you wish to restore. 

10.  Click 

Restore Now

11.  When the system restore has completed you will be logged out. 

 

1.  Log back in to the Enterprise. 

Login and Swap the Unique Identifiers of the removed and newly installed Nodes 

2.  Select 

Setup : Site Settings : Network Nodes

3.  Select from the 

Name

 drop-down the node which you removed. 

4.  Click the 

Commands

 tab. 

5.  Click the 

Swap

 button. 

6.  In the dialog box select from the drop-down the newly installed node. 

NOTE

: If other nodes are powered you may need to know the Unique identifier for this new 

node to make the correct selection. You can use nnconfig.exe to get this UID. 

7.  Click 

Save

 and confirm the swap in the popup. 

NOTE

: Since resources (inputs, outputs, readers, etc.) are specific to a node unique 

identifier, the Swap you performed in this procedure has reassigned the old node’s resources 
to the new node. 

8.  Select 

Setup : Site Settings : Network Nodes

9.  Select from the 

Name

 drop-down the old node that you previously removed. 

10.  Click 

Delete

NOTE

: This node is no longer in the network and deleting it will help avoid confusion. 

 

1.  Select 

Setup : Site Settings : Network Nodes

Enable and connect remaining nodes to the Enterprise 

2.  Select a node from the 

Name

 drop-down. 

3.  Click the 

Enabled

 box and make any needed changes to the node’s settings. 

4.  Click 

Save

5.  Repeat steps 2, 3, and 4 for each node in the system. 

6.  Select 

Setup : Site Settings : Network Controller

7.  Check that the nodes are now connected to the Enterprise controller. Each node should 

appear in green with the word 

Connected

Summary of Contents for eMerge Enterprise

Page 1: ... the Network to the eMerge Enterprise 2 Configuring IP Settings 3 Logging in to your eMerge Enterprise 4 Connecting Nodes and Configuring System Resources 4 Specifications 6 Front Panel LEDs 6 Reset Switches and Drive Lights 7 The eMerge Enterprise Hard Drives 8 Migrating from eMerge 3 X to eMerge Enterprise 3 X 9 Version 3 1 and above ...

Page 2: ...nector 100 240 VAC This connector not currently used Network connector NOTE The remaining USB serial and device connectors are not generally used in NetBox applications The back panel of the Enterprise 1U rack mount Fan Power connector 100 240 VAC This connector not currently used Network connector NOTE The remaining USB serial and device connectors are not generally used in NetBox applications Mo...

Page 3: ...n edit any of the settings on this page NOTE If you change the IP address of the eMerge Enterprise be sure to take note of the new address as you will need it to log in later 3 In the Initmode Settings section select No from the drop down This ensures that Init mode will not redisplay when you reboot You can redisplay the Init mode page at any time from the security application by selecting Setup ...

Page 4: ...ttings Network Nodes Configure and Enable the Nodes 2 Select from the Name drop down the node you wish to enable NOTE If there are many nodes it is recommended that you power up one node at a time This will help avoid confusion 3 Click the Rename link under the drop down and enter a name that will help you to identify it e g Office node Parking Garage node NOTE Do not change the Unique Identifier ...

Page 5: ...he controller You can now begin configuring system resources such as time specifications inputs outputs card formats access levels etc Configure system resources 1 Click the Help link in the upper right of the eMerge application page 2 In the Help window click the Contents link at the top 3 On the Contents page click the second link called Initial System Setup Checklist NOTE This topic provides a ...

Page 6: ...ctions of the LEDs PWR TEMP HDD FAN System Reset Alarm Reset Power Inside the Enterprise front cover The front panel of the eMerge Enterprise Ultra has LEDs connector ports and a lockable hard drive door The table beneath explains the functions of the LEDs HDD TEMP FAN POWER Drive door Lock The front plate of the Enterprise Ultra POWER On Green Power is supplied to the unit On Red Redundant power ...

Page 7: ...rprise Ultra lockable drive door Drive Lights On Green Drive OK Off or On Red Drive failure System Reset This button restarts the Enterprise controller processes Alarm Reset The eMerge Enterprise has an audible alarm which sounds when the power temperature or the fan are in an abnormal state Press this to stop the audible alarm Power Press and hold for 3 to 5 seconds to force a power off NOTE It i...

Page 8: ...terprise Ultra will continue to perform its access control functions throughout this process Removing and Replacing Enterprise Ultra Hard Drives 1 Open the lockable drive door 2 Slide the drive lock switch to the left See image below 3 Place a finger into the gap to the right of the drive lock switch and pry the drive removal lever out and to the right This will unseat the drive 4 Pull the drive o...

Page 9: ... Node only blade 2 From the Name drop down select the Node that you will replace 3 Write down the Node name and Unique Identifier for this node You will need to know this later to complete your configuration 4 Select Setup System Maintenance Utilities 5 Click the Shutdown Now button in the System Functions section of this page 6 Please wait for the system countdown to complete and you will hear tw...

Page 10: ...In the dialog box select from the drop down the newly installed node NOTE If other nodes are powered you may need to know the Unique identifier for this new node to make the correct selection You can use nnconfig exe to get this UID 7 Click Save and confirm the swap in the popup NOTE Since resources inputs outputs readers etc are specific to a node unique identifier the Swap you performed in this ...

Page 11: ...municate with the controller See Tech Note 1 for details NOTE It may also be necessary to use nnconfig exe to assign a specific controller IP address to each remote node rather than to allow nodes to Auto Discover the controller 10 Test system access control functions 1 Select Administration Utility Backup System Backup the Enterprise controller 2 Enter a Comment to explain the purpose of this bac...