![IEE 03805-06-0200 Reference Manual Download Page 20](http://html1.mh-extra.com/html/iee/03805-06-0200/03805-06-0200_reference-manual_3864808020.webp)
Industrial Electronic Engineers, Inc.
SIZE
A
CODE IDENT NO.
05464
S03805–06–0200
Van Nuys, California
SCALE N/A
REV C
SHEET 20
5.3
Interface Signals
5.3.1
Serial Interface Signals
The display is designed to be operated by a standard RS–232 serial interface. The user can operate the
module with any interface which meets the following requirements for a "mark" condition and a "space"
condition. The user should observe generally accepted design rules when interfacing to the display.
Space Voltage (V
RX
Data – V
RX
Data RTN)
+3.0 to +25.0 Volts
Mark Voltage (V
RX
Data – V
RX
Data RTN)
–25.0 to +0.8 Volts
6.0
ENVIRONMENTAL CHARACTERISTICS
6.1
Operating
Temperature:
–30 to +80°C
Humidity: (@ 40ºC)
95% RH (non–condensing)
Humidity (
<
40
°
C):
Absolute humidity must be lower the humidity of 95% RH at 40
°
C
Vibration:
10g at 10 to 400Hz (3 axes)
Shock:
10g (all axes)
6.2
Non–Operating
Temperature:
–40°C to +85°C
7.0
OPTICAL SPECIFICATIONS
7.1
Optical Characteristics
Format:
Four lines of 20 characters
Character Font:
5x7 dot matrix with cursor
Character Height w/ cursor:
0.48" (12.1mm)
Character Height w/o cursor:
0.39" (9.9mm)
Character Width:
0.24" (6.1mm)
Overall Active Area:
5.70" x 2.34" (144.9mm x 59.5mm)
Peak Vertical Viewing Angle:
20° below normal plane
Viewing Mode:
Reflective, light field
Item
Symbol
Condition
Min
Typ
Max
Unit
Viewing Angle–Vertical
φ
1–
φ
2
CR=2.0,
θ
=0°
100
120
–
deg.
Viewing Angle–Horizontal*
T
CR=2.0
±45
±55
–
deg.
Contrast ratio (Peak)**
CR
25°C
10
18
–
–
Response time (ON)**
t
r
25°C
–
100
150
mS
–30°C
–
2000
–
mS
Response time (OFF)**
t
f
25°C
–
150
200
mS
–30°C
–
4000
–
mS
* Measured at peak vertical angle,
φ
= –20°
** Measured at peak viewing angles: