15
4.
Selecting frequencies and power output
FREQ SELECT switch is equipped on both TX and RX. POWER MODE
switch is located on TX side only.
FREQ SELECT switch is used to select transmission and receiving
frequency.
FREQ SELECT switch must be same position on both TX and RX.
POWER MODE switch enables you to change the transmission power,
HIGH or LOW.
4.1.
Available frequencies and transmission power
The table shows the available frequencies and transmission power for EU
region.
Channel
position
frequencies
(MHz)
Limitation
Transmitted power
HIGH
LOW
CH1
5190MHz
Indoor only
20mW/Ant. 5mW/Ant.
CH2
5230MHz
Indoor only
DFS AUTO
INDOOR
Indoor use only.
Automatic selection from the
following frequencies.
5270,5310,5510,5550,
5590,5630,5670 MHz
Indoor only
System initialization
(link time) will take
one minute,
and ten minutes at
5590,5630MHz
DFS AUTO
OUTDOOR
Outdoor use allowed.
Same function even if select
either of two positions.
Automatic selection from the
following frequencies.
5510,5550,5590,5630,
5670 MHz
Indoor/Outdoor
System initialization
(link time) will take
one minute,
and ten minutes at
5590,5630MHz
There is a strict regulation allowing certain frequencies for indoor use only.
Please note that uses of unauthorized frequencies outdoors may be a
violation of the law.