Innovative DisplayWorks
GS-1
TROUBLESHOOTING
If your cooler is not working properly:
■
Check the electrical outlet for power, and that the plug is properly inserted.
■
Check to see if the circuit breaker is tripped or the fuse is blown.
■
Check the condenser for proper cleaning.
If your cooler is making noise:
■
Check that the cooler is level and on a flat surface.
If the compressor turns on and off frequently:
■
The room temperature is higher than normal.
■
The door is not closed completely.
■
The door gasket is not sealed well.
■
There is insufficient clearance around the cooler.
■
The temperature is not set properly.
■
The cycling frequency will reduce when all of the cans reach the set temperature.
The following is not a malfunction:
■
It is normal to hear gurgling sounds caused by the flow of refrigerant when each cooling cycle ends.
REFRIGERANT
■
The GS-1 cooler utilizes R134a refrigerant.
SWITCH FUNCTION
5
Inner LED
switch status
Door LED
switch status
Inner LED
condition
Door Green LED
condition
remark
I
I
Always ON
Always ON
Both inner and green LED
always on
I
O
Always ON
Always OFF
Inner LED always on and Green
LED always off
O
I
Off when door closes;
ON when door opens
Always ON
Green LED always on, inner
LED turns on as door opens
O
O
Off when door closes;
ON when door opens
Always ON
Green LED always on, inner
LED turns on as door opens