10.
Initial Setting
Function
Address(Hex)
Data(Hex)
Preset-Shutter
01
00:
1/45s(OFF)
Trigger shutter Mode
04
00:
Normal(Trigger OFF)
Trigger polarity
05
00:
Positive
Trigger input
06
00:
CC1
Partial scan Mode
08
00:
Full frame
Camera output Mode
0A
00:
Medium Configuration 4Tap
Camera Link output
0B
00:
8bit
Camera output bit position
14
00:
12bit data B11
:
B0 output
Camera output bit position
15
00:
12bit data B11
:
B0 output
Flip
18
00:
OFF
Global Reset Mode
19
00:
OFF
LED ON/OFF
1B
01:
ON
Sensor Mode
1C
00:
Low Gain
Manual Gain
20-21
0000:
0dB
Manual Shutter
24-25
0000:
shutter(OFF)
Low Gain CMOS sensor gain register
36
02:
1.5 x
High Gain CMOS sensor gain register
37
26:
10.5 x
Partial scan start position
40-41
0000:
Start position
Partial scan effective line number
50-51
0800:
Effective Line number 2048