Function
Address(Hex)
Data(Hex)
Cursor Position
X Coordinate
3C-3D
LLHH:
min:0(0H) – max:1087(43FH)
Cursor Position
Y Coordinate
3E-3F
LLHH:
min:0(0H) - max:1086(43EH)
Partial Scan
Start Position 1
40-41
LLHH:
min:0(0H) - max:1087(43FH)
*ID2MC-CLD : Color Camera
Start Position Setting -> Only even number
*If you not use partial scan function, you need to set
“start position 1~8=0”.
Start Position 2
42-43
Start Position 3
44-45
Start Position 4
46-47
Start Position 5
48-49
Start Position 6
4A-4B
Start Position 7
4C-4D
Start Position 8
4E-4F
Partial Scan
Effective Line 1
50-51
LLHH:
min:1(1H) - max:1088(440H)
*ID2MC-CLD : Color Camera
Effective Line Setting -> Only even number
*If you not use partial scan function, you need to set
“effective line 1=1088(440H),2~8=0(0H)”.
Effective Line 2
52-53
Effective Line 3
54-55
Effective Line 4
56-57
Effective Line 5
58-59
Effective Line 6
5A-5B
Effective Line 7
5C-5D
Effective Line 8
5E-5F
※
LLHH : The data set with 2 Byte shall be set with Low Byte first, then set with High Byte.
< Example >
Manual Shutter(Address 24-25) ->6671(1A0FH)
STX SR 24 0F 1A ETX