Function
Address(Hex)
Data(Hex)
Vertical start position
40-41
LLHH:
min:0(0H) - max:960(3C0H)
* Setting value :
2 x n
Horizontal start position
42-43
LLHH:
min:0(0H) - max:960(3C0H)
* Setting value :
2 x n
Partial scan
Effective line number
50-51
LLHH:
min:2(2H) - max:962(3C2H)
* When not in use, set the number of valid lines = 962 (3C2H).
* To enable partial scan, change the data at address 08 to 01.
※
LLHH : The data set with 2 Byte shall be set with Low Byte first, then set with High Byte.
< Example >
Manual Gain(Address 24-25) ->767(02FFH)
STX
SR
24
FF
02
ETX