Page 1: ...R DT EVO TEMIC USB R STICK EVO TEMIC 125 kHz RFID Devices for TEMIC LF RFID Tags ...

Page 2: ...k Writing 4 2 5 Block Write Protected 5 2 6 Wake up Command AOR 5 2 7 Reset Tag 5 3 Polling 6 3 1 Software Version Request 6 3 2 Reading Single EM4x02 6 3 3 Standard Block Reading 6 3 4 Block Read Protected 7 iDTRONIC GmbH Ludwig Reichling Straße 4 67059 Ludwigshafen Germany Deutschland Phone 49 621 6690094 0 Fax 49 621 6690094 9 E Mail info idtronic de Web idtronic de Issue 0 1 02 July 2012 Subje...

Page 3: ...and ETX In binary protocol mode all data transmitted must match a specified instruction frame EOT STX ADDP1 ADDP2 ADDS1 ADDS2 ETX BCC This protocol was designed for easy handling Each terminal has an address between 001 and 255 on multipoint communication the terminal address is defined by two ASCII characters included between 0 and between 30 and 3f hexadecimal on selecting mode case On polling m...

Page 4: ...et STX ADDS1 ADDS2 2 ETX BCC where 2 command type Logical Reset It will be send after Set Setup or Set Setup Serial to apply the changes The terminal will not respond to this command The logical reset is the same to shutdown and subsequent restarting of the terminal 2 3 5557 emulation mode on 4x02 With this command you can program a 5557 as a EM 4x02 STX ADDS1 ADDS2 5 CODE ENCODING ETX BCC 5 comma...

Page 5: ...values 0 and 1 ATTENTION after set to 1 a value it cannot be reset to 0 and the block cannot be changed DATA string of 8 characters hexadecimal data to write on the block valid values 0123456789ABCDEF ADDR string of 1 character block to write valid values from 0 to 7 The page is always 0 the 1 page cannot be written The default expiry timeout is 100 milliseconds 2 6 Wake up Command AOR This comman...

Page 6: ... EM4x02 ENCODING encoding type from 0 to 1 0 Apromix If the polling message is correctly received the electronic board answers as follow STX ADDP1 ADDP2 3 U CODE ETX BCC where CODE string of 10 characters the UID tag The default expiry timeout is 100 milliseconds 3 3 Standard Block Reading This command allows you to read a single block when the PWD tag is set to 0 STX ADDP1 ADDP2 4 PAGE ADDR ETX B...

Page 7: ...ock Read Protected PSW string of 8 characters hexadecimal password valid values 0123456789ABCDEF PAGE string of 1 character page belongs to the block to read valid values 0 and 1 ADDR string of 1 character block to read valid values from 0 to 7 If the polling message is correctly received the electronic board answers as follow STX ADDP1 ADDP2 5 DATA ETX BCC DATA contents of the requested block The...