Installation of the Product
p.29
of each device from “F2 SETUP MENU” -> “CUT OFF CHECK”. Second, set the desired output
that will be generated in the event of a cut off from “F2 SETUP MENU” -> “CUT OFF ALARM”.
3.3
Output Connections
Door Lock (Power Fail Safe) Connection (Relay 1)
●
Connect COM port of Relay 1(Gray with Red stripe) to + 12V (Red wire)
●
Connect NC port of Relay 1(Blue with White stripe) to (+) wire of Door Lock Device.
●
Connect GND (Black wire) port to (-) wire of Door Lock Devices.
Door Lock (Power Fail Secure) Connection (Relay 1)
●
Connect COM port of Relay 1(Gray with Red stripe) to + 12V (Red wire)
●
Connect NO port of Relay 1(White with Red stripe) to (+) wire of Door Lock Device
●
Connect GND (Black wire) port to (-) wire of Door Lock Devices
Alarm Device Connection (Relay 2)
●
Connect COM port of Relay 2 (White) to + 12V (Red wire)
●
Connect NO port of Relay 2 (Purple) to (+) wire of Alarm Devices.
●
Connect GND (Black wire) port to (-) wire of Alarm Devices