p.40
PRODUCT INSTALLATION
iTDC
Power Fail Secure Mode
It closes door automatically when power to door lock is disconnected.
Security level becomes high because all the doors are closed in this situation so
somewhere as bank safe is required to install Power Fail Secure Mode.
Power Fail Safe Mode
It opens door automatically when power to door lock is disconnected.
Security level becomes low because all the doors are opened in this situation, so
somewhere as exit is required to install Power Fail Safe Mode.
7.1
2-Door Control
Wiring for door lock and alarm in Power Fail Safe Mode
Door 1
Door Lock
C12V wire of DC12V power device to R1COM port of
iTDC/iTDC-SR main board.
Connect (+) wire of door lock to R1NC port of iTDC/iTDC-SR main
board.
Connect (-) of door lock to GND (-) wire of DC12V power device.
Connect anti-inverse voltage diode between (+) wire and (-) wire
of door loack.
Alarm
C12V wire of DC12V power device to R2COM port of
iTDC/iTDC-SR main board.
Connect (+) wire of alarm to R2NO of iTDC/iTDC-SR main board.
Connect (-) wire of alarm to GND (-) wire of DC12V power device.
Connect anti-inverse voltage diode between (+) wire and (-) wire
of alarm.
Door 2
Door Lock
Connect DC12V +12V wire of DC12V power device to R3COM
port of iTDC/iTDC-SR main board.
Connect (+) wire of door lock to R3NC port of iTDC/iTDC-SR main
board.
Connect (-) wire of door lock to GND (-) wire of DC12V power
device.
Summary of Contents for iTDC
Page 1: ...USER MANUAL iTDC 2 4 DOOR ACCESS CONTROL SYSTEM ...
Page 20: ...FEATURES iTDC p 13 3 DIMENSION Unit inch mm ...
Page 22: ...FEATURES iTDC p 15 Internal TCP IP Module IIM100 ...
Page 79: ...p 72 SETTING CHANGES iTDC ...
Page 87: ...p 80 SETTING CHANGES iTDC ...
Page 101: ...p 94 SETTING CHANGES iTDC 3 SETTING MENU F3 ...
Page 117: ...p 110 SETTING CHANGES iTDC ...
Page 135: ...p 128 APPENDIX iTDC But two functions 1 2 cannot be used at the same time ...