4. SYSTEM INITIALIZATION 

 

After all wiring process is done, you must initialize the iTDC/iTDC-SR. 

Initialization is used to clear all data stored in the controller and reload default setting values (factory setting values). 

During production and test process of the device, arbitrary setting values may be saved. Thus, restore it to default values by 

Initialization.   

Initialization switches are on the upper right side of iTDC/iTDC-SR. Press two initialization switches and then keep it for more 
than 2 seconds then, beep sound will be generated.     

Once beep sound is generated, release the switches then initialization process is starting. After initialization process is done, the 

system restarts and then you can hear 2 beep sounds.   

 

 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 

 

If the Controller is initialized, all ID information and event data stored in the Controller will be 
cleared.  Therefore,  the  Initialization  should  be  performed  by  authorized  person  only.  It  is 
strongly recommended to upload all ID information and events data before initialization. 
After the  initialization, you should  transmit ID, Time, and Door definition from  software to the 
device. 

 

 

 

Caution 

 

Press simultaneously 

Summary of Contents for iTDC-SR

Page 1: ...Quick Installation Guide iTDC iTDC SR EIO88 MULTI DOORS ACCESS CONTROL SYSTEM ...

Page 2: ...eaders instead of No 8 Exit Buttons In this case connect each reader to reader port No 2 of iTDC iTDC SR reader port No 4 of iTDC iTDC SR Figure iTDC iTDC SR Installation Layout to Control 2 Doors No Code PC for installing application software STARWATCH iTDC PRO I II STARWATCH STANDARD iTDC or iTDC SR RS232 RS422 Converter or TCP IP Module IIM7100A Power Reader Door Lock Door Contact Exit Button ...

Page 3: ...igure below is iTDC iTDC SR installation layout to control 3 doors Figure iTDC iTDC SR Installation Layout to Control 3 Doors No Code PC for installing application software STARWATCH iTDC PRO I II STARWATCH STANDARD iTDC or iTDC SR RS232 RS422 Converter or TCP IP Module IIM7100A Power Reader Door Lock Door Contact Exit Button EIO88 ...

Page 4: ...llation layout to control 4 doors Attach EIO88 Figure iTDC iTDC SR Installation Layout to Control 4 Doors No Code PC for installing application software STARWATCH iTDC PRO I II STARWATCH STANDARD iTDC or iTDC SR RS232 RS422 Converter or TCP IP Module IIM7100A Power Reader Door Lock Door Contact Exit Button EIO88 ...

Page 5: ... 1 iTDC iTDC SR No Code Power Port Terminal Block RS422 Communication Port Terminal Block RS232 Communication Port Terminal Block TTL Output Port Terminal Block Relay Output Port Terminal Block Board ID Setting Switch Input Port Terminal Block Reader Port Terminal Block ...

Page 6: ...6 iTDC Quick Installation Guide Mar 11 2010 1 2 1 EIO88 No Code Input Port Terminal Block 1 4 Output Port Terminal Block 5 8 Input Port Terminal Block 1 4 Output Port Terminal Block 5 8 ...

Page 7: ... of DIP switch has assigned address value and the Board ID is the sum value of each switch set to ON position Refer to the example below Figure Position of DIP Switch and Magnification of the Switch Example 1 Example 2 Example 3 1 2 3 Board ID 3 4 32 36 Board ID 36 128 128 Board ID 128 Figure Board ID Setting Example by DIP Switch Board ID must be set before main power connection to the iTDC iTDC ...

Page 8: ... 1ST class EARTH GROUND EARTH GROUND wiring equalizes all ground level to zero and protects the device from the thunderbolt or surge voltage Figure iTDC iTDC SR GND Wiring 3 2 iTDC iTDC SR POWER WIRING Confirm that main power switched OFF before wiring Connect 12V red wire of DC12V power supply to Power terminal block 12V of iTDC iTDC SR Connect GND black wire of DC12V power supply to Power termin...

Page 9: ...functions 2 Connection between RS422 RS232 Converter and iTDC iTDC SR First connect RS422 RS232 Converter to the first iTDC iTDC SR in cross connection as follows Connect RS422 TX Port of the Converter to RS422 RX Port of the iTDC iTDC SR Connect RS422 TX Port of the Converter to RS422 RX Port of the iTDC iTDC SR Connect RS422 RX Port of the Converter to RS422 TX Port of the iTDC iTDC SR Connect R...

Page 10: ...erent then it causes communication error Thus must connect only one end of the Shield wire as the figure above 3 Termination Resistor Connection When you connect RS232 RS422 Converter and iTDC iTDC SR connect Termination Resistor to the start and end points of the wire as the figure above If the length of communication wire is too long in one communication loop it causes communication problem from...

Page 11: ... Port of the first iTDC iTDC SR to RS422 RX Port of the second iTDC iTDC SR Connect RS422 RX Port of the first iTDC iTDC SR to RS422 TX Port of the second iTDC iTDC SR Connect RS422 RX Port of the first iTDC iTDC SR to RS422 TX Port of the second iTDC iTDC SR Next from the second iTDC iTDC SR connect one iTDC iTDC SR to the following iTDC iTDC SR in direct connection as follow Connect RS422 TX Por...

Page 12: ...s are different then it causes communication error Thus must connect only one end of the Shield wire as the figure above 3 Termination Resistor Connection When you connect RS232 RS422 Converter and iTDC iTDC SR connect Termination Resistor to the start and end points of the wire as the figure above If the length of communication wire is too long in one communication loop it causes communication pr...

Page 13: ...ogram to set network and check operation status is contained in Application software iTDC PRO I II STARWATCH STANDARD CD Install IIM100A Configuration Tool and then set TCP IP Module information for communication environment 2 Network Information Setting After TCP IP Module IIM7100 setting program IIM100A Configuration Tool is installed run Start Program Wiznet 7100A_C exe 1 If program is normally...

Page 14: ...P default 0 for Server IP Port Select Server Mode for Network Mode Refer to table below Column Name Setting Value Local IP The IP address assigned from corresponding network Not duplicated Gateway The Gateway assigned from corresponding network Not duplicated Subnet Mask The Subnet Mask assigned from corresponding network Not duplicated Port above 5000 Server IP 0 0 0 0 Port below 0 Mode Server Mo...

Page 15: ...ze and Char of selected TCP IP module Select 30000 for Inactivity Time 0 for Time 0 for Size 00 for Char Refer to table below Column Name Setting Value Inactivity Time 30000 Time 0 Size 0 Char 00 8 If all setting process is completed click Setting to apply network information to TCP IP module After setting is completed Complete Setting message is displayed Click OK and finish setting process ...

Page 16: ...RF reader to Reader Port terminal block D0 of iTDC iTDC SR Connect DATA1 white wire of RF reader to Reader Port terminal block D1 of iTDC iTDC SR Figure Reader Wiring You can use external 12V DC power source for RF reader But in this case you should connect GND of external power source and power GND of iTDC iTDC SR to the same ground Earth GND connection equalizes all ground level to zero and prot...

Page 17: ...Connect Door Contact to Input Port terminal block INPUT_2 of iTDC iTDC SR Door 2 Connect Exit Button to Input Port terminal block INPUT_3 of iTDC iTDC SR Door 2 Connect Door Contact to Input Port terminal block INPUT_4 of iTDC iTDC SR Figure Input Wiring Reader input and output ports are changed depending on setting of the number of doors You have to see the table in 23p of this manual for changes...

Page 18: ...If you install input devices such as a reader and an exit button on the metal flame Earth GND should be connected to the metal frame If you don t connect Earth GND to metal frame static electricity from the metal frame flows in the device then it becomes the reason of malfunctions and shortens device s lives Caution ...

Page 19: ...y Must connect an anti inverse voltage diode between wire and wire of Door Lock IMPORTANT Figure Power Fail Safe Door Lock Wiring Connect an anti inverse voltage diode as shown above when wiring Door Lock or Alarm If you don t an anti inverse voltage diode external noise flows in then it causes some malfunctions such as poor communication unintended changes in system setting etc Also if you connec...

Page 20: ...ock RNO1 of iTDC iTDC SR Connect wire of Door Lock to GND wire of DC12V power supply Must connect an anti inverse voltage diode between wire and wire of Door Lock IMPORTANT Figure Power Fail Secure Door Lock Wiring Reader input and output ports are changed depending on setting of the number of doors You have to see the table in 23p of this manual for changes of ports due to the setting of the numb...

Page 21: ...e or Power Fail Secure But separate power source must be applied and use external Relay in both Power Fail Secure and Power Fail Safe door lock Figure 24V Door Lock and Automatic Door Wiring If you don t use separate power source and external Relay for the 24V door lock and automatic door relays of iTDC may have damages and some malfunctions will appear Caution 24V Automatic Door ...

Page 22: ...vice IMPORTANT Figure Alarm Wiring Connect an anti inverse voltage diode as shown above when wiring Door Lock or Alarm If you don t an anti inverse voltage diode external noise flows in then it causes some malfunctions such as poor communication unintended changes in system setting etc Also if you connect the polarity of diode oppositely the product can be damaged So must connect it in the correct...

Page 23: ...oor Entrance Exit Reader Exit Button Normal Output Alarm Output 3 Door Attach EIO88 Door 1 Entrance Reader 1 iTDC Relay 1 iTDC Relay 2 Exit Reader 2 iTDC Input 1 iTDC Relay 1 iTDC Relay 2 Door 2 Entrance Reader 3 EIO88 Relay 1 EIO88 Relay 2 Exit EIO88 Input 1 EIO88 Relay 1 EIO88 Relay 2 Door 3 Entrance Reader 4 EIO88 Relay 3 EIO88 Relay 4 Exit EIO88 Input 3 EIO88 Relay 3 EIO88 Relay 4 Number of Do...

Page 24: ...ialization switches and then keep it for more than 2 seconds then beep sound will be generated Once beep sound is generated release the switches then initialization process is starting After initialization process is done the system restarts and then you can hear 2 beep sounds If the Controller is initialized all ID information and event data stored in the Controller will be cleared Therefore the ...