background image

 
 
                                                                                                                 

   

 

                                                                          9                                                     

11. Warranty Policy and Limitation of Liability 

 

IDTECK warrants this product against defects in material and workmanship for  the period specified 
below from the date of purchase under normal customer use. This Warranty doesn’t apply: 1) to any 
product  which  has  been  dismantled  without  authorization  of  IDTECK  or/and  has  a  damaged  or 
detached QC label on its back side; 2) to any losses, defects, or damages caused by improper testing, 
operation, installation, maintenance, modification, alteration, or adjustment; 3) to any product with a 
damaged or faded serial number on it; or 4) to any losses, defects, or damages caused by lightning or 
other electrical discharge, natural disaster, misuse, accident or neglect. 
 
This Limited Warranty is in lieu of all other warranties, obligations, or liabilities on the part of IDTECK, 
and  IDTECK  DISCLAIMS  ANY  AND  ALL  WARRANTY,  WHETHER  EXPRESS  OR  IMPLIED,  OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.IDTECK does not, and cannot, 
know who is present, what property is located, where this product will be used; it would be extremely 
difficult to determine the actual damages that may result from a failure of the product to perform as 
anticipated; and the low price of this product is based upon the nature of the product provided and the 
limited  liability  that  IDTECK  assumes.  IDTECK  IS  NOT  RESPONSIBLE  FOR  ANY  PERSONAL 
INJURY, PROPERTY DAMAGE OR LOSS, DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL 
DAMAGES,  OR  OTHER  LOSS,  AND  IDTECK’S  MAXIMUM  LIABILITY SHALL NOT  IN  ANY  CASE 
EXCEED THE PURCHASE PRICE OF THE PRODUCT.   
 

To  obtain  repair  or  replacement  under  the  terms  of  this  warranty,  visit  IDTECK’s  Website 
(http://www.idteck.com) and place an online RMA request.

 After an RMA code is issued, return the 

product along with the authorization RMA code. 
 

>> Warranty Period

 

 

Product Category 

Warranty 

Period 

RF CARD (Active type) 

1 year 

RF READER / FINGERPRINT READER 

3 years 

STANDALONE CONTROLLER 

CONTROL PANEL 

FINGERPRINT CONTROLLER 

MOLDED RF READER 

(RF10, RF20, RF30, RF TINY, IP10, IP20, IP30, SR10E, SR10UE, SR10SE, SR10RWE, 

SR10BE) 

Lifetime 

RF CARD (Passive type) 

(IDC80, IDC170, IDK50, IMC125, LXK50, IPC80, IPC170, IPK50, ISC80, ISC80S, ISK50, 

IMC135, IHC80, IP100, IP200) 

Summary of Contents for iPASS IP30

Page 1: ...User s Manual Proximity Card Reader ...

Page 2: ...neral 3 3 Features 4 4 Specification 4 5 Identifying Supplied Parts 5 6 Installation 5 7 Wire Color Table of the Reader 6 8 Wire Connection to Access Controller 6 9 Operation 7 10 FCC Registration Information 8 11 Warranty Policy and Limitation of Liability 9 ...

Page 3: ... to qualified service whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used 8 Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is dama...

Page 4: ...s Third Party Controllers 4 Specification Model RF30 IP30 CPU 8bit Microprocessor Read Range IDC170 IDC80 Up to 12 inches 30cm IPC80 IPC170 Up to 12 inches 30cm Reading Time Card 30ms Power Current DC12V Max 350mA Input Port 2 Ports External LED Control External Buzzer Control Output Format 26bit Wiegand Default RS232 and ABA track II Optional LED Indicator 2 Color LED Indicators Red and Green Bee...

Page 5: ...s 3 3 8 38cm apart in vertical and drill one 1 2 hole for the reader cable 1 7 4 31cm apart from the top hole If you have installed an electric gang box then skip this step and go to step 4 2 6 2 Put reader cable into the center hole and install the reader module by using two 6 32 or M3 screws Not included 6 3 Put bezel on to the reader module then push bezel until you hear the locking sound ...

Page 6: ... 12V Red Power Ground GND Black ABA Track II CP Out Orange Wiegand Data 0 Out ABA Track II Data Out Green Wiegand Data 1 Out ABA Track II Clock Out White Buzzer Control In Blue LED Control In Yellow RS232 TX Purple Not Connect Brown Not Connect Gray Please cut out tail connector before installation ...

Page 7: ...xt reading 9 3 LED Control To change the LED colors you may connect the LED Control Input Yellow wire to ground and the Green LED will turn on indicating that the reader is in standby mode Present proximity card and the LED will change color to Red then Green again for the next reading 9 4 Beeper Control In normal operation the reader generates one beep when it reads a proximity card however addit...

Page 8: ...ant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radi...

Page 9: ...t property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure of the product to perform as anticipated and the low price of this product is based upon the nature of the product provided and the limited liability that IDTECK assumes IDTECK IS NOT RESPONSIBLE FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR LOSS DIRECT ...

Page 10: ...nter Product without RMA Code is not accepted If you have any questions or problems regarding the RMA services please contact us using the contact information below Friendly representatives at IDTECK are always standing by to provide the best after sales services IDTECK Headquarter 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E m...

Page 11: ...11 MEMO ...

Page 12: ...0HE2X The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com ...

Reviews: