IDTECK ILAN422 Connection Manual Download Page 2

Model 

ILAN422/485

 

Manual Connection 

Guide 

 

2

 

b. Connection Table 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

3. Connection via RS232 (for ILAN422/485 converter) 

a.  Dip Switch Setup 

For RS232 communication, you should set the DIP switch to the 232 
position as shown in the picture below. 

 

 
 
 
 
 
 
 
 
 
 
       

 

b. Connection Table 

 

   
     
 
 
 
 
 

 
 
 

Star 505R / Star FINGER007

ILAN485 Converter 

Join RX+ (Brown wire)   
and TX+ 

 

(Gray wire) 

485 + 

Join RX- 

 

(Blue Wire)   

and TX-  (Yellow Wire) 

485 - 

ICON100 / iTDC 

ILAN485 Converter 

RX+ and TX+ 

485 + 

RX- and TX- 

485 - 

RFL200C 

ILAN485 Converter 

RX+(Gray wire) 

485 + 

RX-(Orange Wire) 

485 - 

Star 505R / Star FINGER007 

9 Pin Connector (Female)

RXD(Red wire with White Stripe) 

TXD (Pin 3) 

TXD(Black wire with White Stripe)

RXD (Pin 2) 

GND (Black wire) 

GND (Pin 5) 

iCON100 / iTDC 

9 Pin Connector (Female)

RXD 

TXD (Pin 3) 

TXD 

RXD (Pin 2) 

GND 

GND (Pin 5) 

Summary of Contents for ILAN422

Page 1: ...Table 2 Connection via RS485 for ILAN485 converter a Dip Switch Setting For RS485 communication you should set the DIP switch to the 485 position as shown in the picture below Star 505R FINGER007 ILAN422 Converter RX Brown Wire T RX Blue Wire T TX Gray Wire R TX Yellow Wire R iCON100 iTDC ILAN422 Converter RX T RX T TX R TX R The operating voltage may vary depending on the country Check the voltag...

Page 2: ...ar FINGER007 ILAN485 Converter Join RX Brown wire and TX Gray wire 485 Join RX Blue Wire and TX Yellow Wire 485 ICON100 iTDC ILAN485 Converter RX and TX 485 RX and TX 485 RFL200C ILAN485 Converter RX Gray wire 485 RX Orange Wire 485 Star 505R Star FINGER007 9 Pin Connector Female RXD Red wire with White Stripe TXD Pin 3 TXD Black wire with White Stripe RXD Pin 2 GND Black wire GND Pin 5 iCON100 iT...

Page 3: ...f the system are all correct 3 From the list left click on the Converter you d like to configure 4 Enter the IP Address Subnet Mask and click Alter to save the information 5 Close the dialog box Then wait for about 5 seconds and press Refresh to update data Double click on the Converter you ve just configured and the Converter Web configuration window will open If you have a STARWATCH software CD ...

Page 4: ...mary DNS according the domain environment 3 Serial Port Mode Set the Serial Type and Baud Rate of the Converter Serial Type Select the serial type RS232 RS485 and RS422 are supported depending on the type of the Converter Baud Rate Set the Baud Rate of the serial port according to that of the connected equipment If the baud rate of the connected equipment is 9600 select 9600 4 Operation Mode Selec...

Reviews: