background image

 

 

101-091                                                                                            13         

                                               

FGR006 – Version 3.0 

 

IDTeck – FGR006 FINGERPRINT & PROXIMITY READER

 

5. Communication 

 

 
The communication setting is defaulted to RS422. 
If you need the change of the mode of the communication, FGR006 
(FGR006EX) must set on the links on the MAIN PCB. 
Changing this jumper setting requires the use of a soldering iron. 
CAUTION: Damage to the PCB will void warranty. 
 
 

 
 

5.1 Address Setting for RS485/RS422 Communication 

 

There is 8bit DIP SW for address setting and it turns to 8bit binary code as below and each bit has fixed 
address value, the address is calculated the sum value of each bit set to “1” position. 
 

 

 

 

              Example 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NOTE: To select the address switch 
to “ON” switch it down. 

NOTE: Address Setting 

If used with a Ness – IDTeck 

iCON 

control panel

 with Dual Pro software 

then the address 

must start at 33 (

(i.e 1 

& 6 down)) regardless of how many 
controllers you have online. 
 
If used with a Ness – IDTeck 

iTDC 

control panel

 with iTDC Pro software 

then the address 

must start at 100

. (i.e 3, 

6 & 7 down) regardless of how many 
controllers you have online. 
 

If used with 3

rd

 party controllers refer to 

your vender for address instructions 

Summary of Contents for FGR006

Page 1: ...IDTeck FGR006 Fingerprint Proximity Reader Rev 3 0 USER S MANUAL ...

Page 2: ...nnection of FGR006EX 4 4 Network Connection of FGR006 4 5 For Example 4 5 1 Power 4 5 2 Input Connections FGR006EX Only 4 5 3 Output Connections 4 5 4 Error Signal Connection 5 Communication 5 1 Address Setting for RS485 RS422 Communication 5 2 RS232 Communication Port Connection 5 3 RS485 Communication Port Connection 5 4 RS422 Communication Port Connection 6 Operation 6 1 Master Card Registratio...

Page 3: ...here may be a risk of fire or heavy damage of the unit ON MAINTENANCE Do NOT use any kind of liquid for cleaning There may be a risk of electric shock fire or heavy damage of the unit Use an air spray if needed Users are cautioned NOT to attempt repair of this product or modify the wirings set by the installer at their own discretion It may pose the risk of fire hardware damages or abnormal operat...

Page 4: ...ting reader to metal door frame mullion or to any flat wall surface FGR006 ensures you a successful operation where you want biometrics access control FGR006 has three LED of red green and lens upper right inside beeper sound to guarantee you an accurate and reliable access control 2 3 Specification CPU 32bit dual 8bit Microprocessor Memory Program Memory 64KB EEPROM Power DC 12V 350mA max Card Ho...

Page 5: ...es user cards Reader Mode If your fingerprint is authorized then FGR006 will send your card ID to the access controller Master Card A master card is used to change modes from Registration to reader modes A Card Number Output Form If your fingerprint is authorized then output becomes the card number to 26bit Wiegand or ABA Track II according to an output type An Error Signal Output If your fingerpr...

Page 6: ...nd GND BLACK INPUT Only available with RS232 RS485 Communication LED Control Input LED BROWN Beeper Control Input BEEP BLUE WIEGAND OUTPUT Wiegand Data 0 DATA0 GREEN Wiegand Data 1 DATA1 WHITE Finger Error ERROR ORANGE Note that the Finger Error output is only available with Wiegand output ABA TRACK II OUTPUT Card Present CLS Orange Clock CLK White Data DATA Green RS232 COMMUNICATION PORT RS232 RX...

Page 7: ...TION PORT RS485 A 485A Grey RS485 B 485B Yellow RS422 COMMUNICATION PORT Î DEFAULT RS422 TX TX Grey RS422 TX TX Yellow RS422 RX RX Brown RS422 RX RX Blue TAMPER SWITCH Tamper Switch TAMPER Purple EXTERNAL READER PORT FGR006EX Only Wiegand Data 0 IN_DATA0 Pink Wiegand Data 1 IN_DATA1 Cyan ...

Page 8: ...der then put reader cable into the centre hole and install the main unit by using two 3 16 screws 4 1 3 Put bezel into the main unit then push bezel until you hear the locking sound 4 2 System Initialisation You can H W initialise using DIPswitch First turn on the system power and turn off all Dipswitches Set the DIPswitch after an initialisation completion DIP Switch use for address of RS422 RS48...

Page 9: ...101 091 9 FGR006 Version 3 0 IDTeck FGR006 FINGERPRINT PROXIMITY READER 4 3 Wire Connection of FGR006 4 4 Wire Connection of FGR006EX ...

Page 10: ... Points and Tip 4 6 1 Recommended cable type and permissible length of cable Need thicker wire if you connect the reader with high current consumption Description Cable Specification Maximum Distance Belden 9512 22 AWG 4 conductor shielded Reader Power and Data Reader ACU Belden 9514 22 AWG 8 conductor shielded 150m ...

Page 11: ... 0 therefore the reader output can not be read correctly from the ACU You have to think about how you reduce the voltage drop between both ends of GND wire There will be two methods to reduce the voltage drop and ACU can read data correctly Reduce the DC resistance of GND wire Using thick cable or add more wires to GND wire in parallel If you connect 4 wires in parallel for GND the DC resistance o...

Page 12: ...ilable with RS232 RS485 communication A green LED turn on if the short does LED CONTROL INPUT wire with the GND The beep sound appears if the short does BEEPER CONTROLER INPUT wire with the GND 4 7 3 Output Connections 26bit Wiegand Output ABA Track II Output 4 7 5 External Reader Connection FGR006EX Only ...

Page 13: ...and it turns to 8bit binary code as below and each bit has fixed address value the address is calculated the sum value of each bit set to 1 position Example NOTE To select the address switch to ON switch it down NOTE Address Setting If used with a Ness IDTeck iCON control panel with Dual Pro software then the address must start at 33 i e 1 6 down regardless of how many controllers you have online ...

Page 14: ... COM2 Port of PC Install and run Application Software 5 3 RS485 Communication Port Connection You set the jumper with a silkscreen side up RS 485 RS 232 converter is required to connect serial communication RS485 between Main Unit and PC Personal Computer The converter used CNP200A Connect RS485 A Grey wire of Main Unit to Red wire of CNP200A converter Connect RS485 B Yellow wire of Main Unit to G...

Page 15: ...fter initialisation becomes the Master Card For master card registration mode refer to the 7 Operation Indication of Reader Register of manual Note A Master card cannot be used for access 6 1 2 A Master Card Change You can register Master Card again after initialisation of hardware CAUTION If you initialise the hardware all user data are deleted You can change the master card by using the applicat...

Page 16: ...s not registered then FGR006 will make 2 beep sounds and return to reader mode Put your finger on the fingerprint scanner for authorization If your fingerprint is authorized then FGR006 will turn on the lens led upper light and make a beep sound for a second and will send your card ID to the access controller If your fingerprint is not authorized then FGR006 will make 2 beep sounds and generate fi...

Page 17: ... proximity card to the FGR006 It beeps 4 times when the deletion is completed After deletion present proximity master card again and it is changed to reader mode It beeps 2 times when the deletion is error 6 4 Auto match Function OPTION 1 This function operates in the Reader mode User can be verified with Fingerprint template only No card necessary Sensor will be activated automatically when user ...

Page 18: ...R006 to connect directly to a PC or Notebook via RS232 for fingerprint registrations It is used to connect with FGR006 and RS232 port of PC or notebook It uncover TOP CASE in FGR006 Extract after you pull TOP CASE bottom of FGR006 It insert RS232 serial jack at bottom of FGR006 It connects a d sub connector with RS232 port of PC or notebook ...

Page 19: ...s supplied Register Master Card The unit is initialised and master card is unregistered Registration Mode Add Delete user Reader Mode Verify user card Initialisation The unit is initialised Initialisation Completed System initialisation is completed 7 2 Beeps sound status BEEP SOUND TIMES STATUS 1 time 1second Access granted 2 times Error Fingerprint or operation error 3 times Register user card 4...

Page 20: ... for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does...

Page 21: ...20 www ness com au email ness ness com au NSW 4 167 Prospect Hwy Seven Hills NSW 2147 Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au Vic 24 Terracotta Drive Blackburn Vic 3130 Ph 03 9875 6400 Fax 03 9875 6422 nessmelb ness com au QLD Unit 3A 471 Lytton Road Morningside Qld 4170 Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au W A Unit 1 567 Newcastle Street Perth W A 6000 Ph 08 9328 2511 ...

Page 22: ...101 091 22 FGR006 Version 3 0 IDTeck FGR006 FINGERPRINT PROXIMITY READER MEMO ...

Page 23: ...101 091 23 FGR006 Version 3 0 IDTeck FGR006 FINGERPRINT PROXIMITY READER MEMO ...

Page 24: ...101 091 24 FGR006 Version 3 0 IDTeck FGR006 FINGERPRINT PROXIMITY READER ...