Section 1
INTRODUCTION

Scans and Decodes Bar Codes

ID TECH’s VersaScan II CCD Scanner is specially designed to deliver high-end 
performance. The scanner utilizes exceptional decoding technology. One time settings 
are easily made by scanning set-up barcodes in the handy Quick Start manual.  

Programmable for Specialized Usage

Not only does the VersaScan II read and decode all popular barcode
symbologies, it can also format the scanned data to meet the user’s needs. Barcode 
symbologies are individually selectable, as are reading mode, beep tone, 
preamble/postamble, and code ID. For full programming User’s Manual, please visit 
www.idtechproducts.com to download. 

Ergonomic and Lightweight

The VersaScan II contains no moving parts. It is lightweight and designed to fit 
comfortably in the hand for extended periods of use. The cable is detachable for easy 
replacement or to change interfaces.

High-Speed Long Range Scanning

The VersaScan II enables quick scanning of barcodes up to 5.1 inches in width at 
distances up to 8.7 inches away. Small or high-density bar codes as well as damaged 
or low-quality barcodes can be read quickly and accurately at a scan rate of 450 scans 
per second.

Features & Benefits:

• Ergonomic design for superior handling
• Long range scanning up to 8.7 inches
• Rugged design for industrial environment
• Supports all major 1D symbologies, PDF 417 and most Databar variants
• Trouble-free interchangeable communication cable between Keyboard Wedge,     
  RS232, and USB Keyboard interface
• Data editing features
• Easy Configuration cloning capability
• 450 scans per second
• Auto-Sensing and Continuous mode

Section 2
SPECIFICATION

Electrical

 

 

 

 

Power Requirement: +5 VDC ± 5%, 370mA operating; 240 mA standby 

Interfaces: RS-232, Keyboard Wedge, USB (Keyboard)

 

Light Source: 660 nm visible red LED with focus light bar 

Sensor: 2088 pixel CCD array 

 

 

 

 

Environmental

 

 

 

 

Operating Temperature: 32° F to 122° F (0° C to 50° C) 

Storage Temperature: -4° F to 140° F (-20° C to 60° C) 

Relative Humidity: 20 to 85%, non-condensing 

Drop Test: 5.9 feet (1.8m) to a hard surface 

 

 

 

 

Mechanical & Optical

 

 

 

 

Dimensions(L)x(W)x(H): 6.3 inches(160mm) x 2.7 inches(69mm) x 3.5 inches(88mm) 

Weight: 4.4oz (125g) / without cable 

Indicator: LED, beep tone 

Color: Black housing 

Field Width: 5.1 inches (130mm) 

Depth of Field: 45-110mm on 5 mil (Code 39) 

Resolution: 0.1mm (4mil) 

PCS: 0.6 minimum 

Scan Rate: 450 scans per second 

Range: 1.2 to 8.7 inches (30 to 220 mm) based on EAN 15.6mil 

Symbologies: Code 39, UPC-A, UPC-E, Code 128, EAN-13/8, EAN 128, 

Interleaved 2 of 5, Code 32, MSI UK Plessey, IATA Code, 
Code 2 of 5 (China Postal Code), Industrial 2 of 5, Matrix 2 
of 5, Code 93, Code 11, Telepen code, RSS code, PDF417 

Safety Approvals: FCC class B and CE 

Ambient Light: 20,000 Lux (Fluorescent Light) 

 

- 3 -

- 4 -

Summary of Contents for VersaScan II

Page 1: ...Quick Start Manual VersaScan TM Barcode Scanner ID TECH 10721 Walker Street Cypress CA 90630 714 761 6368 www idtechproducts com 80105501 001 rev A II...

Page 2: ...ID TECH s satisfaction to be thus defective The expense of removal and reinstallation of any item or items of equipment is not included in this warranty No person firm or corporation is authorized to...

Page 3: ...nge scanning up to 8 7 inches Rugged design for industrial environment Supports all major 1D symbologies PDF 417 and most Databar variants Trouble free interchangeable communication cable between Keyb...

Page 4: ...isconnect the keyboard cable from the computer 3 Connect the Y cable between the keyboard the scanner and the computer 4 Restart the computer 5 The scanner will beep once 6 Set the scanner to KEYBOARD...

Page 5: ...igger is released The LED is always on when the trigger is pressed The LED will go off if no bar code has been detected after 60 seconds The LED lights automatically when a bar code is detected If Aut...

Page 6: ...om www idtechproducts com The scanner does not scan when the trigger is pressed 1 Unplug the cable from the host computer 2 Plug the cable back in the host computer 3 Set the scanner to the correct in...

Page 7: ...2 1 5 UPC A 123456 Code 39 7147616368 UCC EAN 128 0 1 2 3 4 5 6 5 UPC E 7147616368 Code 128 7147616368 Interleaved 2 of 5 DATABAR STACKED OMNIDIRECTIONAL 7147616368 DATABAR 7147616368 7147616368 DATAB...

Page 8: ...Full User s Manual is available for download on www idtechproducts com 7147616368 PDF417 Section 8 TESTING CODES 13 7147616368 DATABAR EXPANDED 7147616368 DATABAR EXPANDED STACKED 14...

Reviews: