background image

Page |  25   

 

Norway (Northern Sami) 

0005011 

Sweden, Finland   
(Swedish, Finnish) 

0005012 

Slovak (Slovakia) 

0005013 

 

Portuguesa (Portuguese) 

0005014 

 

Czech Republic (Czech) 

0005015 

 

Belgium (Dutch) 

0005016 

Turkey-F 

0005017 

Turkey-Q 

0005018   

Poland (Polish214) 

0005019   

Switzerland (German, French) 

0005020   

Croatia (Srb-Crt) 

0005021   

Summary of Contents for ValueScan III IDBB-4244MRB

Page 1: ...ValueScan III IDBB 4244MRB Barcode Scanner User Manual 80181501 001 Version 1 4 December 20 2019 ...

Page 2: ... to the user manual are listed below Version Date Description Page 1 0 2019 10 18 Initial release 1 2 2019 11 20 Updated the specifications of the scanner 56 1 3 2019 12 02 Style update 1 4 2019 12 20 Added Presentation Mode images 7 ...

Page 3: ...e is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the...

Page 4: ...ote All brands and trademarks are the property of their respective owners The specifications contained herein are subject to change without notice 警告使用者 這是甲類的資訊產品 在居住的環境中使用時 可 能會造成射頻干擾 在這種情況下 使用者會被要 求採取某些適當的對策 ...

Page 5: ...s 14 4 5 Character Delete Insert and Replacement Settings 15 4 6 Serial Port Settings 18 4 7 Normal Function Setting Codes 20 4 8 Prefix and Suffix Settings 22 4 9 Multi Language Setting Codes 24 4 10 Character Tables 27 4 11 Enable and Disable Barcodes 39 5 PREFIX SUFFIX CODE SETTING INSTRUCTIONS 52 5 1 Common pre suffix code 52 5 2 Adding an exclusive suffix code 53 5 3 Sleep time setting button...

Page 6: ...onvolatile memory The embedded memory saves the settings when the power is turned off Turn off the computer s power before connecting the scanner power up the computer after the scanner is fully connected To change a parameter value scan the appropriate bar codes in this guide These new values replace the default values in memory Note Most computer monitors allow you to scan bar codes directly on ...

Page 7: ...CCD image sensor Scan Speed 270 times sec Maximum reading resolution 3mil 0 762mm Depth of Field 15 330mm EAN 13mil 0 33mm PCS 90 Drop resistance 1 5 meters onto concrete Auto sensing presentation mode available Just scan the Presentation Mode barcode on the Stand to easily switch to presentation mode for the VALUESCAN III scanner Presentation Mode ...

Page 8: ...eceive your scanner open the package immediately and inspect for shipping damage If you discover any damage contact the shipping company and file a claim ID TECH is not responsible for any damage incurred during shipping Save all packing materials for the shipping company to inspect Note If any item is missing please contact your local dealer ...

Page 9: ...the RJ45 connector into the scanner s RJ45 port until it clicks 2 Insert the USB connector to your computer 3 Turn on your computer It will autodetect your scanner 4 To test your scanner start a text editing program like Notepad or Microsoft Word Scan a bar code to see if the scanner can send data to your computer If it s successful you ll hear a beep and see the bar code data in the text editing ...

Page 10: ...Scanning Barcodes VALUESCAN III emits a light bar when scanning To scan a barcode make sure the aiming beam crosses every bar and space of the barcode This bar needs to cross the bar code horizontally to decode it ...

Page 11: ...ences The following section provides information about changing your scanner s controls and settings 4 1 Version Information Setting Codes Version custom 000A0 Display internal string custom 000A1 Display serial number custom 000A2 Factory default 000B0 Enable the code setting function 09990 Disable the code setting function 09991 ...

Page 12: ...puter via a serial interface e g COM1 COM8 but your computer does not have a serial port the scanner requires a virtual COM port driver Use this driver to assign a virtual COM port connection number to devices connected via a USB port and to enable bidirectional communication between your computer and the VAUESCAN III Get the USB virtual COM port driver from the ID TECH global website Download and...

Page 13: ...3 4 3 Scan Mode Setting Codes Trigger mode default 013340 Continuous scan mode 013344 Presentation mode 013380 Key delay 013342 Single not triggered 013341 Key delay not triggered 013343 Auto flashing 013345 ...

Page 14: ...Page 14 4 4 Sound Setting Codes Sound on default 014201 Sound off 014200 Buzzer frequency 2048 0145800 High volume sound 014300 Low volume sound 014301 Buzzer frequency 2731 0145AAA ...

Page 15: ...1402 Display code front character default 0201x Hide code front blank 0200 SPACE Display code rear character default 0203 Hide code rear character n n indicates a blank key 0202 SP Display characters inside code default 0205 Hide inside code 0204 Disable A replace 0 in code default 020600 Enable A replace 0 in code 02060A ...

Page 16: ... characters 023301 Display front characters default 023400 Hide front 5 characters 023405 Display middle characters default 023900 Hide 5 middle characters 023905 Forward start from 4th character 024004 FUNC1 replace with 1 0160049 FUNC2 replace with 2 0161050 FUNC3 replace with 3 0162051 ...

Page 17: ...Page 17 FUNC4 replace with 4 0163054 Disable enter replace default 0182013 Enter replace with 5 0182055 ...

Page 18: ... rate 1200bps 000702 Baud rate 2400bps 000703 Baud rate 4800bps 000704 Baud rate 9600bps default 000705 Baud rate 19200bps 000706 Baud rate 38400bps 000707 Baud rate 57600bps 000708 Baud rate 115200bps 000709 Serial Port No Check 001200 Serial port XON OFF 001201 ...

Page 19: ...13020 Serial port handshake timeout 5s 0013050 Serial port 8 bit data 00080 Serial port 7 bit data 00081 Serial port 1 stop bit 00090 Serial port 2 stop bits 00091 Serial port No parity check 001000 Serial port odd parity check 001001 Serial port even parity check 001002 ...

Page 20: ...setting barcodes default 02500 FUNC cast light upon cancel default 01640 Disable change 02510 All uppercase 02511 All lowercase 02512 Uppercase interchange with lowercase 02513 Enable command beep 01411 Disable command beep 01410 Forward image identify default 00161 Reverse image identify 00160 ...

Page 21: ...Page 21 Fastest transmit rate 001500 Medium transmit rate default 001502 Lower transmit rate 001504 Lowest transmit rate 001506 ...

Page 22: ...es rear add ETX 0211 ETX All barcodes front add F2 02160081 All barcodes rear add F2 02110081 Cancel all barcodes rear format character 0210 Add STX before barcodes 0217 STX Cancel all boots before barcodes 0215 Add prefix 02240 Add suffix 02241 Exit add pre suffix Mode 02242 ...

Page 23: ... Clear all prefix 02220 Clear all suffix 02200 Enter hidden front character mode 02340 Enter hidden rear character mode 02341 Enter hidden middle character mode 02342 Enter the hidden Nth character mode 02343 ...

Page 24: ...ault 0005000 Canada French 0005001 Dutch Netherlands 0005002 Spain Spanish 0005003 Argentina Latin American 0005004 Brazil Portuguese 0005005 Denmark Danish 0005006 UK English 0005007 Italy Italian142 0005008 France French 0005009 German Germany 0005010 ...

Page 25: ...and Swedish Finnish 0005012 Slovak Slovakia 0005013 Portuguesa Portuguese 0005014 Czech Republic Czech 0005015 Belgium Dutch 0005016 Turkey F 0005017 Turkey Q 0005018 Poland Polish214 0005019 Switzerland German French 0005020 Croatia Srb Crt 0005021 ...

Page 26: ...Page 26 Hungary Hungarian 0005022 Japan Japanese 0005023 Russia Russian 0005024 Arabic Egypt 0005025 ...

Page 27: ...Page 27 4 10 Character Tables For adding prefixes and suffixes 1001 SOH 1003 ETX 1002 STX 1004 EOT 1006 ACK 1005 ENQ 1007 BEL 1009 TAB 1008 Backspace 1010 Line 1012 FF 1011 VT ...

Page 28: ...Page 28 1013 Enter 1015 SI 1014 SO 1016 DLE 1018 DC2 1017 DC1 1019 DC3 1021 NAK 1020 DC4 1022 SYN 1024 CAN 1023 ETB 1025 EM 1027 ESC ...

Page 29: ...Page 29 1026 SUB 1028 FS 1030 RS 1029 GS 1031 US 1033 1032 SPACE 1034 1036 1035 1037 1039 1038 ...

Page 30: ...Page 30 1040 1042 1041 1043 1045 1044 1046 1048 0 Note Used to set address prefix suff ix 1047 1049 1 Note Used to set address prefix suffix 1051 3 Note Used to set address prefix suffix ...

Page 31: ...to set address prefix suffix 1054 6 Note Used to set address prefix suffix 1053 5 Note Used to set address prefix suffix 1055 7 Note Used to set address prefix suffix 1057 9 Note Used to set address prefix suffix 1056 8 Note Used to set address prefix suffix 1058 1060 1059 ...

Page 32: ...Page 32 1061 1063 1062 1064 1066 B 1065 A 1067 C 1069 E 1068 D 1070 F 1072 H 1071 G 1073 1075 ...

Page 33: ...Page 33 I K 1074 J 1076 L 1078 N 1077 M 1079 O 1081 Q 1080 P 1082 R 1084 T 1083 S 1085 U 1087 W ...

Page 34: ...Page 34 1086 V 1088 X 1090 Z 1089 Y 1091 1093 1092 1094 1096 1095 _ 1097 a 1099 c 1098 b ...

Page 35: ...Page 35 1100 d 1102 f 1101 e 1103 g 1105 i 1104 h 1106 j 1108 l 1107 k 1109 m 1111 o 1110 n 1112 p 1114 r ...

Page 36: ...Page 36 1113 q 1115 s 1117 u 1116 t 1118 v 1120 x 1119 w 1121 y 1123 1122 z 1124 1126 1125 ...

Page 37: ...Page 37 1127 Delete 1129 F2 1128 F1 1130 F3 1132 F5 1131 F4 1133 F6 1135 F8 1134 F7 1136 F9 1138 F11 1137 F10 1139 F12 1141 HOME ...

Page 38: ...Page 38 1140 INSERT 1142 Page up 1144 END 1143 Delete 1145 Page down 1147 Left arrow 1146 Right arrow 1148 Down arrow 1149 Up arrow ...

Page 39: ... as m 0031m Enable code39 Full ASCII default 00231 Disable code39 Full ASCII 00230 Disable code39 MOD43 Check default 00240 Enable code39 MOD43 Check 00241 Enable code39 transmit check 00251 Disable code39 transmit check 00250 Disable code39 transmit default 00280 Enable code39 transmit 00281 ...

Page 40: ...gth of 1 Software version available before and after V7 53 003201 Setting the CODE39 to a minimum length of 2 default Software version available before and after V7 53 003202 Setting the CODE39 to a minimum length of 3 Software version available before and after V7 53 003203 Code39 minimum length 1 software version available before V7 53 00321 Code39 minimum length 2 default Software version avail...

Page 41: ...lt 00341 Disable UPC A 00340 UPC A ID as e 0049e Enable UPC A change to EAN 13 00391 Disable UPC A change to EAN 13 default 00390 Transmit UPC A check digit default 00421 No transmit UPC A check digit 00420 UPC A display system digit 00400 UPC A hide system digit 00401 Enable UPC E default 00351 ...

Page 42: ...o UPCA 00381 Disable UPC E change to UPC A default 00380 UPC E hiding system characters 00431 UPC E sending system characters 00430 UPC E sending check digits 00441 UPC E not sending check digits 00440 Enable EAN 13 default 00361 Disable EAN 13 00360 EAN 13 ID as d 0051d ...

Page 43: ...N 13 change to ISBN 00481 Disable EAN 13 change to ISBN default 00480 Enable EAN 13 change to ISSN 01501 Disable EAN 13 change to ISSN default 01500 Enable EAN 13 multiple verify 00541 Disable EAN 13 multiple verify default 00540 Enable EAN 8 default 00371 Disable EAN 8 00370 EAN 8 ID as c 0052c ...

Page 44: ...570 EAN 8 hide system digit 00561 EAN 8 display system digit default 00560 Enable 5 digit supplement 00552 Enable 2 digit supplement 00551 Enable 2 digit 5 digit supplements 00553 Disable supplement default 00550 Enable code93 default 00621 Disable code93 00620 Code93 ID as i 0066i ...

Page 45: ...fault 00680 Enable Code93 MOD47 default 01901 Disable Code93 MOD47 01900 Enable code128 default 00691 Disable code128 00690 Code128 ID as a 0081a Disable code128 multiple verify default 00840 Enable code128 multiple verify 00841 Enable codabar default 00851 Disable codabar 00850 ...

Page 46: ...haracter without transmission default 00860 Enable interleaved 2 of 5 default 00961 Disable interleaved 2 of 5 00960 Interleaved 2 of 5 ID as n 0104n Interleaved 2 of 5 minimum length 4 009704 Enable Interleaved 2 of 5 ID check 00981 Disable Interleaved 2 of 5 ID check 00980 No transmission of check on Interleaved 2 of 5 ID 00991 ...

Page 47: ...nk mode 01001 Disable bank mode 01000 Enable industrial 2 of 5 default 01061 Disable industrial 2 of 5 01060 Industrial 2 of 5 ID as o 01130 Industrial 2 of 5 minimum length 3 010703 Enable MSI 01151 Disable MSI default 01150 MSI ID as s 0053s MSI minimum length 4 011804 ...

Page 48: ...0 Plessey ID as t 0117t Plessey minimum length 3 011903 Enable code11 default 01261 Disable code11 01260 code11 ID as u 0131u Code11 minimum length 4 012804 Code11 auto CK check 01271 Code11 C check default 01272 Code11 CK check 01273 Enable Matrix 25 default ...

Page 49: ...trix 25 minimum length 2 014802 Matrix 25 minimum length 3 014803 Enable postal 25 01571 Disable postal 25 default 01570 Postal 25 ID as r 0158r Postal 25 minimum length 5 015905 Postal 25 minimum length 7 015907 Enable aerial 25 01871 Disable aerial 25 default 01870 ...

Page 50: ...N 02371 Disable EAN change to ISSN default 02370 All EAN change to ISBN 02361 Disable EAN change to ISBN default 02360 Enable digital keyboard mode 02581 Disable digital keyboard mode 02580 Enable GS1 Omni directional 01671 Disable GS1 Omni directional default 01670 GS1 Omni ID as j 0168j ...

Page 51: ...01770 GS1 Limited ID as k 0178k Note The setting code type is code128 When generating a barcode you must add 3 before the barcode for example 3 required barcode The ASCll codes in the above table are all decimal For hexadecimal ASCII codes refer to ASCII Table 2 ...

Page 52: ...e suffix code 1 For the first method scan a barcode additive and the setting code is 0223X prefix code and 0221X suffix code 0223 and 0221 stands for one common pre suffix code where the value of X represents the added character and this X is a binary For example to add a common pre suffix code A the setting code is 0221A which means that the suffix code A is added to all barcodes Input the follow...

Page 53: ...cimal setting code is 02160041 In addition you must add a character after the barcode and then add Enter To add the character after the bar code and then add Enter use the setting code is 0213 r the suffix code is 0212 non accumulative 0213 accumulative 2 times and 0211 accumulative 3 times 5 2 Adding an exclusive suffix code One type of barcode must be added with an exclusive suffix code For exam...

Page 54: ... Sleep time setting code 0310nnn If X seconds of sleep is required and calculated in hexadecimal 4 for base the formula is x 4 NNN For example if it takes 60 seconds to automatically shut down the setting code is 0310015 If it takes five minutes to automatically shut down the setting code is 0310015 Sleep time limit 42 minutes and 47 seconds 2 Button timeout setting code 0235nn If the button timeo...

Page 55: ...ange the number of hidden characters To hide middle characters you must use two setting codes at the same time 0239nn to hide nn characters in the middle and 0240nn to start hiding characters after the first nn characters For example if the barcode is 123456789 and you wish to hide 456 the setting codes are 023903 to hide the three middle characters and 024003 to begin hiding characters after the ...

Page 56: ...S1 LIMI M 0D CODE39 N 0E Interleaved 2 of 5 O 0F Industrial 2 of 5 P 10 Aerial25 Q 11 Matrix 25 R 12 Postal 25 S 13 MSI T 14 PLESSEY U 15 CODE11 V 16 CODABAR Lookup table for specific keys and code values ASCII code values available for standard characters F1 0x80 F2 0x81 F3 0x82 F4 0x83 F5 0x84 F6 0x85 F7 0x86 F8 0x87 F9 0x88 F10 0x89 ...

Page 57: ...End 0x90 Right 0x92 Left 0x93 Down 0x94 Up 0x95 If CODE93 is added with the STX prefix code according to the STX ASCII value that is 0x02 then the setting code content should be printed as shown below 5 5 Tip 1 ASCII F3 0 2 1 6 I STX Binary F3 0x30 0x32 0x31 0x37 0x49 0x02 Setting barcode ...

Page 58: ... ASCII F3 0 2 1 6 0 9 0 2 And if CODE93 is added with Home prefix code ASCII F3 0 2 1 6 0 9 8 D Note Code93 corresponds to 09 value of each code that is given in the note on the previous page the home key value is 0x8D ...

Page 59: ...ry 6 6 Confirmation 7 7 Ring 8 8 backspace 9 9 Level positioning character 10 0A Line feed new line 11 0B Vertical positioning character 12 0C Form feed new page 13 0D Enter 14 0E Shift out 15 0F Shift in 32 20 space 33 21 34 22 35 23 36 24 37 25 38 26 39 27 40 28 41 29 42 2A 43 2B 44 2C 45 2D 46 2E 47 2F 48 30 0 49 31 1 50 32 2 51 33 3 ...

Page 60: ...6 42 B 67 43 C 68 44 D 69 45 E 70 46 F 71 47 G 72 48 H 73 49 I 74 4A J 75 4B K 76 4C L 77 4D M 78 4E N 79 4F O 16 10 Data link translation 17 11 Device control 1 18 12 Device control 2 19 13 Device control 3 20 14 Device control 4 21 15 Reverse confirmation 22 16 Synchronous idle 23 17 Transmission block end 24 18 Cancel 25 19 Media end ...

Page 61: ...eparator 30 1E Record separator 31 1F Unit separator 80 50 P 81 51 Q 82 52 R 83 53 S 84 54 T 85 55 U 86 56 V 87 57 w 88 58 X 89 59 Y 90 5A Z 91 5B 92 5C 93 5D 94 5E 95 5F _ 96 60 97 61 a 98 62 b 99 63 c 100 64 d 101 65 e 102 66 f 103 67 g 104 68 h 105 69 i 106 6A j 107 6B k 108 6C l 109 6D m 110 6E n 111 6F o ...

Page 62: ...Page 62 Decimal Hexadecimal Character 112 70 p 113 71 q 114 72 r 115 73 s 116 74 t 117 75 u 118 76 v 119 77 w 120 78 x 121 79 y 122 7A z 123 7B 124 7C 125 7D 126 7E 127 7F DEL ...

Page 63: ... 1 000 000 cycles Light Source RED LED 620nm 630nm Image Sensor 2500 point pixel CCD image sensors Interface USB HID USB Virtual COM Indication LED Beeper Performance Resolution 3mil 0 76mm Print Contrast Min 20 Scan Rate 270 time s Scan Angle Yaw 55 Rotation 30 Pitch 65 Environment Light Strength 70 000 Lux Temperature Operating temp 20 C to 50 C Storage temp 40 C to 70 C Humidity 5 to 95 Non con...

Reviews: