1.

 

Setup 

1.1

 

Required or Recommended User Equipment 

By default, the internal supply voltage for powering the Sensor Board is generated from the USB voltage supplied by the user’s computer via 
the USB cable. If there is a need for currents higher than the defined USB standard (usually 500mA at 5V), an external voltage supply source 

can be used instead of the internally generated voltage supply provided on the Communication Board. 
The external supply only powers the sensor modules, and not the communication board itself. The supply must meet the following requirements: 

 

Voltage – 1.7V to 3.6V 

 

Current must meet the user’s specifications – The minimum is 30mA for electronics with additional current needed for each gas sensor 
module of approximately 11mA (with a 1.8V voltage supply).  

1.2

 

User Computer Requirements 

1.2.1

 

Computer Requirements 

A Windows-based computer is required for interfacing with the EVK and configuring the ZMOD4510. The user must have administrative rights 

on the computer to download and install the Gas Sensor Evaluation Software.  
The computer must meet the following requirements: 

 

1GB RAM 

 

Hard drive with at least 250MB free space 

 

1 USB port 

 

Windows Vista

®

/Windows 7

®

/Windows 8

®

/Windows 10

®

 

 

Internet access for initial download of the drivers and software 

Important: Before installing and activating the software, assemble and connect the hardware for the kit to the user’s computer according to 
steps 1 through 3 in “EVK Hardware Connections and Initial Power-up.” 

1.3

 

Software Installation and Setup 

Before  using  the  Gas  Sensor  Evaluation  Software,  the  USB  drivers  for  the  FTDI  device  must  be  installed.  Download  the  drivers  and 
corresponding  installation  guides  from  the  FTDI  website  (

www.ftdichip.com

).  The  drivers  will  not  affect  the  operation  of  any  other  USB 

peripherals. The kit does not need to be connected during installation of the drivers.  
Complete the following procedure to download and install the ZMOD4510 Evaluation Software with the kit connected: 
1.

 

Download the ZMOD4510 Gas Sensor Evaluation Software zip file at 

www.IDT.com/ZMOD4510-EVK

. 

2.

 

Create a folder on the user’s computer for the software (e.g., C:\Program Files (x86)\IDT Software). Extract the contents of the 
downloaded zip file into this folder.  

3.

 

Double-click on the extracted executable file Gas_Sensor_Evaluation.bat to start the software each time the program is used and 
select the ZMOD4510 – Outdoor Air Quality option. Figure 1 shows the initial display after execution. 

Summary of Contents for ZMOD4510-EVK

Page 1: ...on Board has devices mounted on both sides The components on the top side generate a stable supply voltage A potentiometer can be used to adjust the internal supply voltage in the typical range from 1...

Page 2: ...E OF TRADE CUSTOM OR COURSE OF DEALING Restrictions in Use IDT s ZMOD4140 Evaluation Kit consisting of the HiCom Communication Board ZMOD4510 Sensor Board and the ZMOD4510 Evaluation Software is desig...

Page 3: ...rnal Supply Voltage 7 Figure 4 Initial Display for the ZMOD4510 Start up 8 Figure 5 Communication Board Schematic Page 1 10 Figure 6 Communication Board Schematic Page 2 11 Figure 7 Sensor Board Schem...

Page 4: ...ing requirements 1GB RAM Hard drive with at least 250MB free space 1 USB port Windows Vista Windows 7 Windows 8 Windows 10 Internet access for initial download of the drivers and software Important Be...

Page 5: ...he proper orientation of the Sensor Board as shown on page 1 3 Insert the micro USB cable into the X1 connector on the Communication Board and connect it to a free USB port on the user s computer If t...

Page 6: ...er This connector can be used to connect the ZMOD4510 in different configurations or to measure the communication lines and voltages on the ZMOD4510 Sensor Board AD5 is a GPIO pin that can be controll...

Page 7: ...ints on Communication Board for the Internal or External Supply Voltage K2 Jumper If using the internal supply set the jumper to the int position If using an external supply set the jumper to the ext...

Page 8: ...start sensor button is clicked the button name changes to stop sensor and the measurement starts running continuously with the given sample time the default is 1 minute The results will be saved in a...

Page 9: ...plots Algorithm Result The first 10 measurements of the algorithm will be taken for sensor stabilization During this time the Algorithm Result section will indicate the completion progress Note that t...

Page 10: ...ZMOD4510 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 10 August 14 2019 3 Schematics Figure 5 Communication Board Schematic Page 1...

Page 11: ...ZMOD4510 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 11 August 14 2019 Figure 6 Communication Board Schematic Page 2...

Page 12: ...ZMOD4510 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 12 August 14 2019 Figure 7 Sensor Board Schematic...

Page 13: ...100nF 0603 10 C13 100nF 0603 11 C14 100nF 0603 12 C15 100nF 0603 13 C16 100nF 0603 14 C17 10 F 16V 0805 15 C18 27pF 0603 16 C19 27pF 0603 17 C20 10 F 16V 0805 18 C21 10 F 16V 0805 19 C22 100nF 0603 20...

Page 14: ...4 90 42 K4 K2X7 LH 14 43 K5 V_EXT 1X02 44 L1 10 H 1210 45 L2 10 H 1210 46 L3 10 H 1210 47 Modul1 Honeywell480 3652 1 ND DIL8 SMD Socket 48 Q1 12 00MHz QUARZ ABM3 49 R1 1k 0805 50 R2 1k 0805 51 R3 1 6k...

Page 15: ...Table 4 Sensor Board BOM Designator Quantity Manufacturer Manufacturer Part Number C1 2 Taiyo Yuden LMK105BJ104KV F U1 1 IDT ZMOD4510 X1 1 Sullins SFH11 PBPC D07 ST BK 5 Board Layout Figure 8 HiCom C...

Page 16: ...ZMOD4510 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 16 August 14 2019 Figure 10 Sensor Board Layout Top Layer Figure 11 Sensor Board Layout Bottom Layer...

Page 17: ...products The information contained herein is provided without representation or warranty of any kind whether express or implied including but not limited to the suitability of IDT s products for any p...

Reviews: