3.3.

 

Adding the Remote Transmitter to a User code 

To add a bi-directional Xwave

2

 remote transmitter to a user code. 

1.

 

Enter the Master User Menu 

2.

 

Scroll to menu [Add Bidir Remote] or enter [1][6][*] 

3.

 

Enter the Hub that you are teaching the remote too 

4.

 

Enter the user code that will be paired with the remote 

5.

 

Press any remote button until the remotes ID is displayed 

6.

 

Press [*] to confirm 

7.

 

Enter the next user code if more than one remote is to be learnt or [#] to exit. 

 

3.4.

 

Allocating Remote Transmitter Buttons 

To change the button functions: 

1.

 

Enter the Master User Menu 

2.

 

Scroll to menu [Edit BD Buttons] or enter [1][7][*] 

3.

 

Enter the Hub that the remote belongs too 

4.

 

Enter the user code that was paired with the remote 

5.

 

Scroll through the buttons until the button to be changed and press [*]  

6.

 

Scroll through until the function required and press [*] to confirm 

7.

 

Enter the parameter followed by [*] to confirm (The parameter will be the partition 

number or the output number.) 

 

See a list of functions below: 

Function 

Parameter  Description 

Unassigned 

-- 

No function allocated. 

Arm 

Partition 

Number 

Will only arm the partition allocated to button and user code. 

Disarm 

Partition 

Number 

Will only disarm the partition allocated to button and user code. 

Arm/Disarm 

Partition 

Number 

Will only arm or disarm the partition allocated to the user code. 

Global Arm 

 

Will only arm the partitions allocated to the user code. 

Global Disarm 

 

Will only disarm the partitions allocated to the user code. 

Global 

Arm/Disarm 

 

Will only arm or disarm the partitions allocated to the user code. 

Stay Arm 

Partition 

Number 

Will arm the allocated partition in the current/last used stay profile. 

Stay Arm Prof1  Partition 

Number 

Will arm the allocated partition in stay profile 1 and then allow you to scroll 

to the next available profile if one is configured. 

Stay Arm Prof2  Partition 

Number 

Will arm the allocated partition in stay profile 2 and then allow you to scroll 

to the next available profile if one is configured. 

Stay Arm Prof3  Partition 

Number 

Will arm the allocated partition in stay profile 3 and then allow you to scroll 

to the next available profile if one is configured. 

Stay Arm Prof4  Partition 

Number 

Will arm the allocated partition in stay profile 4 and then allow you to scroll 

to the next available profile if one is configured. 

Stay & Go 

Partition 

Number 

Will arm the allocated partition in the current/last used stay profile. 

Stay & Go 

Prof1 

Partition 

Number 

Will arm the allocated partition in stay & Go in stay profile 1 and then allow 

you to scroll to the next available profile if one is configured. 

Stay & Go 

Prof2 

Partition 

Number 

Will arm the allocated partition in stay & Go in stay profile 2 and then allow 

you to scroll to the next available profile if one is configured. 

Summary of Contents for Xwave2

Page 1: ...tters It is wired to the X Series panel in the same way as all other peripheral devices on the keypad bus 1 Installation Xwave2 works on the IDS X Series panels versions 2 7 and above 1 1 Addressing T...

Page 2: ...LED indicates the bi directional networks information The LED will be ON in normal operation with no errors If there are errors it will start pulsing the error number TROUBLE LED indicates troubles wi...

Page 3: ...t learnt to a hub it will send out join requests every 20 seconds There are two ways you can learn an Xwave2 detector 1 Go to Location 260 Sub Location 1 select the zone number and type in the serial...

Page 4: ...ction 1 ON Detector LED 2 ON On for a pulse count of 2 and Off for a pulse count of 4 3 Xwave2 Remotes The user menu is used to add edit delete remotes 3 1 Remote Transmitter Each remote transmitter h...

Page 5: ...isarm the partition allocated to the user code Global Arm Will only arm the partitions allocated to the user code Global Disarm Will only disarm the partitions allocated to the user code Global Arm Di...

Page 6: ...ending on the type of output to switch from 12V to 0V and back to 12V or from a closed state to an open state and back to a closed state Pulse length setup under the output properties PGM PulseH PGM N...

Page 7: ...st mode the device will trigger continuously when an object has been detected and the LED will come on to indicate the detection To enter devices into walk test mode 1 Enter the Master User Menu 2 Scr...

Page 8: ...he time the dialler waits before trying to dial again in the event it failed to report to the basestation 6 2 Location 251 258 Keypad Options Sub locations 7 and 8 have been added to the keypad option...

Reviews: