IDS Xwave2 User Manual Download Page 1

 

 

IDS X-Series v2.7 

Change Guide 

 

 

Introduction 

 

With X-Series v2.7 comes the new Xwave 

2

. The latest in bi-directional wireless technology that 

will ensure your detectors are properly supervised. 

 

Xwave

2

 

 

The IDS X-Series Bi-directional Xwave

2

 Hub offers an additional 16 wireless supervised zones 

and two programmable outputs. The hub can also learn up to 16 Xwave

2

 Bi-directional remote 

transmitters. It is wired to the X-Series panel in the same way as all other peripheral devices, on 

the keypad bus.  

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

Installation 

Xwave

2

 works on the IDS X-Series panels, versions 2.7 and above. 

 

1.1.

 

Addressing 

To address the Xwave

Hub, set the dipswitches as per the table below. Depending on what 

address is used on the Hub will determine the zone numbers it uses. 

Note: The unit must be powered down when selecting the unit’s address. 

 

Binary value on switch 

Hub zones 

 Dipswitch 1 up 

1 -16 

Dipswitch 2 up 

17 - 32 

Dipswitches 1 + 2 up 

33 – 48 

Dipswitch 3 up 

49 - 64 

Dipswitch 6 up 

3 second button panic disabled  

 

Summary of Contents for Xwave2

Page 1: ...tters It is wired to the X Series panel in the same way as all other peripheral devices on the keypad bus 1 Installation Xwave2 works on the IDS X Series panels versions 2 7 and above 1 1 Addressing T...

Page 2: ...LED indicates the bi directional networks information The LED will be ON in normal operation with no errors If there are errors it will start pulsing the error number TROUBLE LED indicates troubles wi...

Page 3: ...t learnt to a hub it will send out join requests every 20 seconds There are two ways you can learn an Xwave2 detector 1 Go to Location 260 Sub Location 1 select the zone number and type in the serial...

Page 4: ...ction 1 ON Detector LED 2 ON On for a pulse count of 2 and Off for a pulse count of 4 3 Xwave2 Remotes The user menu is used to add edit delete remotes 3 1 Remote Transmitter Each remote transmitter h...

Page 5: ...isarm the partition allocated to the user code Global Arm Will only arm the partitions allocated to the user code Global Disarm Will only disarm the partitions allocated to the user code Global Arm Di...

Page 6: ...ending on the type of output to switch from 12V to 0V and back to 12V or from a closed state to an open state and back to a closed state Pulse length setup under the output properties PGM PulseH PGM N...

Page 7: ...st mode the device will trigger continuously when an object has been detected and the LED will come on to indicate the detection To enter devices into walk test mode 1 Enter the Master User Menu 2 Scr...

Page 8: ...he time the dialler waits before trying to dial again in the event it failed to report to the basestation 6 2 Location 251 258 Keypad Options Sub locations 7 and 8 have been added to the keypad option...

Reviews: