IDS X-Series v2.7
Change Guide
Introduction
With X-Series v2.7 comes the new Xwave
2
. The latest in bi-directional wireless technology that
will ensure your detectors are properly supervised.
Xwave
2
The IDS X-Series Bi-directional Xwave
2
Hub offers an additional 16 wireless supervised zones
and two programmable outputs. The hub can also learn up to 16 Xwave
2
Bi-directional remote
transmitters. It is wired to the X-Series panel in the same way as all other peripheral devices, on
the keypad bus.
1.
Installation
Xwave
2
works on the IDS X-Series panels, versions 2.7 and above.
1.1.
Addressing
To address the Xwave
2
Hub, set the dipswitches as per the table below. Depending on what
address is used on the Hub will determine the zone numbers it uses.
Note: The unit must be powered down when selecting the unit’s address.
Binary value on switch
Hub zones
Dipswitch 1 up
1 -16
Dipswitch 2 up
17 - 32
Dipswitches 1 + 2 up
33 – 48
Dipswitch 3 up
49 - 64
Dipswitch 6 up
3 second button panic disabled