IDS | Wireless Hardware
4
Wireless Hardware
Warning
1.
Older wireless hardware devices will not work with the X64, Duevi integration. Please make sure that you have
the correct version of each device.
2.
The Duevi wireless peripheral device defaults are:
a.
Tamper switches disabled.
b.
Supervision time set to 24 hours on the following devices, 866-DX-PWF Wireless Door Contact, 866-DX-
PWF Indoor Wireless PIR
c.
90 minutes supervision time for 866-DX-OPWF Outdoor Dual Head PIR and the 866-DX-EWF E-wall
3.
Supervision failure will occur when a device does not check in for the time set in; location 260 sub-location 3. The
zone will violate and remain violated until the device sends violation signal or a supervision signal.
a.
Make sure that all devices are set to the correct supervision time.
For example:
If the X64 is set to 24 hour supervision then each device can be set to 24 hour or 90
minute check-in, but if set to 3 hours then each device must be set to 90 minute check-
in.
4.
Tamper per zone for wireless zones are set the same as wired zones in location 101 to 164 depending on which
zones are to be monitored.
5.
Wireless receivers can monitor sixteen devices at a time in sequential blocks: zones 1 to 16, 17 to 32, 33 to 48
and 49 to 64. (How to set which receivers monitor which group of zones will be discussed later.)
For example: A wireless receiver configured to monitor zones 1 to 16 cannot see zone 17 or any other
zone that is not in the first sixteen zones, even if it has only one device learnt to it.