background image

Section: 3 

 

IDS X64 LCD Keypad User Manual   700-411-01C   Issued August 2010 

To provide greater flexibility the panel caters for the programming of four different STAY PROFILES. Each 

STAY  PROFILE  contains  a  unique  combination  of  STAY,  BUZZ  and  ALARM  zones  that  cater  for  a 

particular STAY ARM requirement. 

 

EXAMPLE:       

PROFILE 1 might be used when the family goes to bed in the evening. In this profile, some interior zones 

may  be  programmed  as  alarm  zones  or  buzz  zones,  whereas  PROFILE  2  is  utilised  while  watching 

television when all interior zones would be bypassed. (See section 9.1 How to Select a Stay Profile.) 

3.2.1

 

How to Stay Arm                                                      

 

[#] [USER CODE] (Do not leave premises) 

 

1.

 

Select the required STAY PROFILE. (See Section 9.1) 

2.

 

Ensure that the LCD display reads „Ready to Arm‟ alongside the partition number being armed. If 

not, check that all protected doors and windows are closed and that all movement has ceased in 

the areas covered by motion detectors. 

3.

 

Press the 

[#]

 key. 

4.

 

Enter a valid 

[USER CODE]

. If an incorrect code is entered, the keypad will give an error beep. 

In the event of an error, press the 

[#]

 key and re-enter the 

[USER CODE]

5.

 

DO NOT violate the Entry/Exit zone (normally the front door). If the Entry/Exit zone is violated the 

system will arm in the AWAY mode. 

6.

 

The  LCD Keypad  will  read  „Exit  Delay‟,  the  ARM LED  will come  on and  the  keypad buzzer  will 

sound for the duration of the exit delay. 

7.

 

When the panel arms, any STAY zones will be automatically bypassed. These are displayed on 

the LCD display as solid text. Any violated zones will be displayed on the LCD display as flashing 

text. To scroll through zones which have been bypassed or violated use the 

[PANIC]

 and 

[MED]

 

keys. 

8.

 

Ensure that you enter only those areas that are bypassed. 

3.2.2

 

Quick Stay Arm - Shortcut Key                                              

 

(Hold down the [5] key for 2 seconds until the keypad buzzer sounds) 

 

It is possible to STAY arm by holding down the 

[5]

 key until the keypad buzzer sounds. The panel will 

immediately arm into stay mode without any exit delay. Holding the

 

[5] 

key again will toggle between the 

4 stay profiles. 

The LCD display will read „Stay Armed‟ and will indicate any zones that have been bypassed. One is able 

to scroll through the list of bypassed, as well as violated, zones by using the 

[PANIC]

 and 

[MED]

 keys. 

 

Quick Select Method: 

 

Press the [5] key simultaneously with the [PROFILE NUMBER] and release  

 

1.

 

Ensure that the Panel is disarmed. 

2.

 

Press the

 

[#]

 key to clear any previous entries. 

3.

 

Press the 

[5]

 key and then simultaneously press keys 

[1]

[2]

[3]

, or 

[4]

 – depending on the 

stay profile you want to choose – then release both keys.  

4.

 

A beep will sound to indicate successful selection of a profile. 

5.

 

Program STAY and BUZZ zones for the profile (see sections 9 and 10), and/or ARM the profile 

(with the 

[5]

 key). 

Summary of Contents for X64

Page 1: ...IDS X64 LCD Keypad User Manual 700 411 01C Issues August 2010 1...

Page 2: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 2...

Page 3: ...Alarms 12 6 1 Fire Alarms 12 6 2 Panic Alarms 12 6 3 Medical Alarms 12 6 4 Duress Alarms 13 7 Alarm Memory 13 7 1 Event Log 13 8 User Codes 14 8 1 Adding Deleting and Editing User Codes 14 8 2 How to...

Page 4: ...4 9 2 How to Program Cancel Stay Zones 24 10 Buzz Zones 24 10 1 How to Program Cancel Buzz Zones 25 11 Chime Zones 25 11 1 How to Program Cancel Chime Zones 25 12 Viewing Trouble Conditions 26 13 Chan...

Page 5: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 5...

Page 6: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 6...

Page 7: ...tion number Ready to Arm if there are no violated zones otherwise it will display V zone Number zone name for about 3 seconds for each violated zone EXAMPLE If there are no zone violations the keypad...

Page 8: ...nly via a designated exit route The panel will away arm at the end of the exit delay if any enter exit zone is violated e g the front door 6 Once the panel has armed the LCD display will read Armed al...

Page 9: ...eypad will read Exit Delay the ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay 7 When the panel arms any STAY zones will be automatically bypassed These are di...

Page 10: ...splay as flashing text Use the PANIC and MED keys to scroll through zones that have been bypassed or violated The keypad buzzer will sound for the duration of the exit delay Only leave via a designate...

Page 11: ...on is registered the strobe will continue flashing after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe 4 2 How to Disarm using a Key Switch or Remote 1 Activate the...

Page 12: ...moke detector connected to an appropriately programmed zone The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE will be transmitted to the monitoring company To silenc...

Page 13: ...Ds will turn off and the keypad buzzer will sound briefly 3 Use the MED or PANIC keys to scroll through the zones violated during the last armed period 4 Press the 1 key to return to violated zones 5...

Page 14: ...modify or delete user codes See Table 1 for a summary of programmable options The programmable interface is accessed by entering the USER PROGRAMMING MODE Table 1 User Programming Options Options Summ...

Page 15: ...tion 0 will be displayed on the LCD screen by default Press the key to confirm your entry Once prompted to Enter a User Code input a NEW USER CODE followed by the key Once the user code is programmed...

Page 16: ...until you reach Menu Option 2 Press the key 4 The LCD display reads User Code 5 Enter the USER CODE to be deleted followed by the key Deleting the code in slot one will reprogram it to 1234 6 Further...

Page 17: ...ay reads User Code 5 Enter the USER CODE followed by the key the slot number is displayed on the keypad 6 Further slot numbers may be viewed by repeating step 5 7 Press the key to exit the User Progra...

Page 18: ...r It is advisable to choose a code that can be easily remembered by all family or staff members 8 3 7 3 Maid s Code This code can be used to limit access to the premises A maid s code will only disarm...

Page 19: ...2 The LCD display reads Option Menu Add User Code 3 To select menu option 11 User Partitions press the 1 1 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable o...

Page 20: ...pander 1 output 1 27 Reserved 07 Zone expander 1 output 2 28 Reserved 08 Zone expander 2 output 1 29 Reserved 09 Zone expander 2 output 2 30 Reserved 10 Zone expander 3 output 1 31 Reserved 11 Zone ex...

Page 21: ...e stay close RC OFF Disable stay close RC 3 ON Enable open RC OFF Disable open RC 4 ON Enable siren cancel RC OFF Disable siren cancel RC 5 ON Enable access RC OFF Disable access RC 8 3 11 Option 15 U...

Page 22: ...ion 30 Edit Zone Name press the 3 0 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options until you reach the option you want 4 Press the key 5 The LCD dis...

Page 23: ...he format is HHMM 7 Press the key to exit the User Program Mode 8 3 14 Option 41 Edit the Date MASTER CODE 4 1 DATE 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The LCD display read...

Page 24: ...ber indicates that that particular zone is programmed as a stay zone 6 Press the key to toggle between YES and NO NOTE Buzz zones will be shown by flashing LEDs See Section 10 A Buzz zone cannot be se...

Page 25: ...ected as a Buzz zone 11 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated the...

Page 26: ...ition has restored To cancel the beeping without viewing the trouble conditions press the key Table 7 Trouble Conditions Zone LED Trouble Condition 1 Panel AC Supply Failure 2 Panel Communications Fai...

Page 27: ...ff 1 Hold MODE down for one second until the keypad beeps twice 2 The LCD display reads Mode Number 3 Press the 3 key followed by the key 4 The LCD display reads Output Num 5 Enter the OUTPUT NUMBER f...

Page 28: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 28...

Page 29: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 29...

Page 30: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 30...

Page 31: ...odes Enable Master Code 1 4 User Code Bitmap User Reporting Code Telephone Master Code 1 5 User Code Bitmap Edit a Zone Name Master Code 3 0 Zone No Zone Name Edit the Time Master Code 4 0 Time Edit t...

Page 32: ...IDS X64 LCD Keypad User Manual 700 411 01C Issued August 2010 32...

Reviews: