background image

 

X-SMS 700-485-01E 

 

 

   

 

       

X-SMS V2 Quick User Guide 

THANK YOU FOR CHOOSING IDS TO PROTECT YOU 

Thank you for purchasing an IDS X-SMS V2 module. IDS X-SMS V2 offers powerful, 
versatile and highly configurable reporting and control capabilities, which will keep 
you, informed and in control of your X-Series alarm system when away from your 
premises.  
NOTE: The X-SMS V2 module works only with IDS X-Series panels above a certain 
version. Your X-Series alarm panel is a sophisticated professional-grade intrusion 
product designed to protect lives and property, and can only be installed and 
maintained by a professional IDS-certified installer. The Installer Manual included in 
this box does not cover all aspects of installation; these are available only to 
installers via our sales offices.  
NOTE: Please read the entire Quick User Guide before attempting to use the X-SMS 
V2 device! 
NOTE: 
Throughout this manual, the default user code 1234 is used. Commands will 
only be accepted by the alarm panel if preceded by a valid user code, programmed 
into the alarm panel by your installer. 
FEATURES OF THE IDS X-SMS V2 DEVICE 

 

Take full remote control of your X-Series alarm panel 

o

 

Arm / disarm 

o

 

Bypass / un-bypass zones 

o

 

Home automation via PGM’s 

 

Keep in touch with your premises 

o

 

Receive customised reports on panel status and events 

o

 

Check current panel status  

o

 

Check recent activity by retrieving event logs 

 

Enhance the functionality of your X-Series alarm panel: 

o

 

Using names in reporting and commands 

o

 

Update your panel’s time and date via the mobile network 

 

Manage your X-SMS V2 device remotely 

o

 

Lock X-SMS V2 in event of lost phone 

o

 

Check and top up SIM airtime balance  

o

 

Add, manage and remove X-SMS V2 users  

COMMAND FORMAT 

Commands are not case sensitive and all follow the same format: 

[code] space [command] space [extended command] space [data
Code – Valid alarm user code stored in the alarm panel 

Command – A string that identifies the function that you are wanting to access in 
the alarm panel. 
Extended Command – Any supplementary information the function requires. (Not 
always required will depend on the function being used.) 
Data - Any extra information the extended command requires.  
NOTE: The cell networks limit the number of characters to 160. 
Arm / Disarm 

The X-Series panel’s 8 partitions may be armed in multiple profiles. Arming requires 
a valid user code. These are programmed by your installer.  
Valid command examples: 

Desired action 

Code 

Command 

Ext. Cmd 

Data 

Away arm all partitions 

1234 

Arm 

 

All 

Away arm P1 & P3 

1234 

Arm 

 

P1, P3 

Stay arm P2 in stay profile 3 

1234 

Arm 

S3 

P2 

Stay arm P1 & P4 in stay profile 

1234 

Arm 

S1 

P1, P4 

Disarm all partitions 

1234 

Disarm 

 

All 

Disarm P2 

1234 

Disarm 

 

P2 

Disarm P5 & P6 

1234 

Arm 

 

P5, P6 

NOTE: Stay profiles can be changed by sending a new stay arm command if armed in 
stay mode already. Away armed partitions must be disarmed before being stay 
armed. 
Bypass / un-bypass zones 

The “Bypass” command will be sent by you to bypass specific zones, and vice versa 
for “unbypass”. You must specify which zones to bypass in the data field. Zones may 
be referred to by their number or, where applicable, by their name.  
Valid command examples: 

Desired Action 

Code 

Command 

Ext. Cmd 

Data 

Bypass zone 1 

1234 

Bypass 

 

Bypass zone 3,4,8,10 

1234 

Bypass 

 

3,4,8,10 

Bypass named zone “Passage”  1234 

Bypass 

 

Passage 

Bypass named zone “Lounge” & 
“Kitchen” 

1234 

Bypass 

 

Lounge, 
Kitchen 

Unbypass Zone 5 

1234 

Unbypass 

  

Unbypass “Kitchen” 

1234 

Unbypass 

  

Kitchen 

Home automation via PGM’s 

Programmable outputs (PGM’s) on your X-Series alarm panel may be used to control 
electrical devices such as lights, gate and garage door motors, pumps, geysers, 
irrigation systems etc. The PGM command controls the programmable outputs 
Note: Installations controlling electrical devices often requires a certified electrician. 
PGM outputs can only supply 80mA of current. 
PGM’s can be triggered in several ways as below – consult your installer for further 
support.  

 

On – Turns the PGM on by putting 12V DC onto the output  

 

Off – Turns the PGM off by removing the 12V DC 

 

PulseH – Puts 12V DC onto the output for 2 seconds 

 

PulseL – Removes 12V DC from the output for 2 seconds 

Desired Action 

Code 

Command  Ext. Cmd 

Data 

Turn PGM 1 on 

1234 

PGM 

 On 

Turn PGM 3, 4 & 5 off 

1234 

PGM 

Off 

3,4,5 

Pulse PGM 2 Low 

1234 

PGM 

PulseL 

Pulse PGM 3 High 

1234 

PGM 

PulseH 

Receive customised reports on panel status and events 

The “report” command is sent to select what reports you want to receive on that 
phone number. Each phone number can choose how they want to receive the 
messages or turn off messages. 
There are four types of SMSes: 
Raw – A Contact ID string will be sent to the phone number 
Full – All enabled events are reported 
Reduced – Only the following will be reported: Arm/Disarm, Zone violations, Panics, 

Medical, Fire, AC Fail/Restore, Battery Low/Restore, Zone tamper/restore. 

Raw – Contact ID string/ readable format 
Minimal – Only the following will be reported: Keypad panic, Medical & Fire, Panic 

or Duress, AC Fail/Restorals, zone violations and Low Battery/restorals, 
Zone tamper 

Valid extended commands: “Type” 

Desired Action 

Code  Command  Ext. Cmd  Data 

Turn on partial reporting   1234  Report 

Type 

Reduced Phone number/ 
Name 

Turn on global reporting   1234  Report 

Type 

Full Phone number/Name 

NOTE: Only a “Master Phone Number” can allocate partitions to a phone number. 
Check current panel status 

Current arm status, zone status, and PGM status can be checked. 
Arm Status 

Desired Action 

Code 

Command 

Ext. Cmd 

Data 

Retrieve the status of  all 
partitions 

1234 

Arm 

Status 

All 

Retrieve the status of  P1 

1234 

Arm 

Status 

P1 

Retrieve the status of  P3 & P6  1234 

Arm 

Status 

P3, P6 

Zone Status 

Desired Action 

Code 

Command 

Ext. Comm 

Data 

Retrieve the status of zones in 
partition 1 

1234 

Zone 

Status 

P1 

Retrieve the status of zones in 
partition 1 & 3 

1234 

Zone 

Status 

P1, P3 

PGM Status 

Desired Action 

Code 

Command 

Ext. Comm 

Data 

Get PGM 8’s status 

1234 

PGM 

Status 

Get PGM Gate’s status 

1234 

PGM 

Status 

Gate 

Bypass Status 

Desired Action 

Code 

Command 

Ext. Cmd 

Data 

Retrieve the status of zones in 
partition 1 

1234 

Zone 

Status 

P1 

Retrieve the status of zones in 
partition 1 & 3 

1234 

Zone 

Status 

P1, P3 

Check recent activity by retrieving event logs 

The “Event” command is sent by you to retrieve a selectable number of events from 
the Alarm event log. 

Desired Action 

Code 

Command 

Ext. Cmd 

Data 

Retrieving 5 Events 

1234 

Event 

Panel 

NOTESMS text is limited by the networks to 160 characters and retrieving event 
logs that exceed 160 characters will amount to a number of SMSes being sent

SMS Threshold 

By default the number of SMSes sent per day per phone number is 20.  
The “threshold” extended command is sent by the phone number that is requesting 
the change to increase or decrease the number of SMSes. 

Desired Action 

Code  Command  Ext. Cmd 

Data 

Increase the reporting 
threshold to 50 SMSes 

1234  Report 

Threshold 

50 Phone 
Number/Name 

Decrease the reporting 
threshold to 14 

1234  Report 

Threshold 

14 Phone 
Number/Name 

Using names in reporting and commands 

The X-SMS V2 device itself, and all partitions, zones, and PGM’s can be named. 
These names are used by default in all reports, and can be used in commands in 
place of the default zone / partition / PGM numbers.  

Desired Action 

Code 

Command 

Ext. Cmd 

Data 

Name PGM 5 Lights 

1234 

PGM 

Name 

5:Lights 

Name the X-SMS V2 device 
“Home” 

1234 

Site 

Name 

Home 

Name partition 1 “Main 
House” 

1234 

Partition 

 Name 

1:Main 
House 

Name partition 2 as “Granny 
Flat” & partition 3 as “Garage” 

1234 

Partition 

Name 

2:Granny 
Flat, 
3:Garage 

Name zone 1 as “Kitchen” 

1234 

Zone 

 Name 

1:Kitchen 

Name zone 2 “Lounge” & 
zone 5 “Patio” 

1234 

Zone 

Name 

2:Lounge, 
5:Patio 

NOTES 

 

The X-Series alarm system does not use site, partition or PGM names, these names 
cannot be added via the keypad. 

 

If a zone is named via SMS it will over write the zone name on the system  

 

If a space is inserted before or after the name then the space becomes part of the 
zone name. 

 

Names are case sensitive 

 
 

Reviews: