13.2.
Aligning Beams
Beams must be aligned correctly for optimal detection and reduced false alarms.
While looking through viewfinder, adjust the horizontal and vertical angles until the
pairing detector is in the centre of the sight. Use the Alarm Indicator LED on the Beam
Receiver for a rough alignment.
Use the Alarm Indicator LED on the Beam Receiver for a rough alignment.
Alarm
Indicator
LED
No Light
Light Received
ON
Fast Blink
Slow Blink
OFF
Adjustment
Level
Realign
Aligned
NB: The Alarm Indicator LED is a tool for easy alignment. You must use the Voltage
Monitor Jack for fine adjustments to get the best performance.
View Finder
Correct Alignment
Incorrect Alignment