background image

IN

HE

P DIGIT

AL

S E

C U R I T

Y

IDS

Users Guide to Keypad

Functions

MANUAL NO. 700-146-01D ISSUED NOVEMBER 2002     VERSION 2.17

Summary of Contents for IDS1600

Page 1: ...I N H EP DIG I T A L S E C U R I T Y IDS Users Guide to Keypad Functions MANUAL NO 700 146 01D ISSUED NOVEMBER 2002 VERSION 2 17...

Page 2: ...1 r o f y c n e g r e m E l a c i d e M n w o d d l o H M d n o c e s 1 r o f y r o m e M m r a l A n w o d d l o H 0 d n o c e s 1 r o f s n o i t i t r a P e g n a h C n w o d d l o H E D O M d n o...

Page 3: ...y Arming 14 5 3 Stay Arming 14 5 4 Quick Stay Arming 15 5 5 Stay Arm and Go 15 5 6 Arming a Partition from a Master Keypad 16 5 7 Arming from a Key Switch or Remote Control 17 5 8 Auto Arming 17 5 9 A...

Page 4: ...13 1 To Program Buzz Zones 32 13 2 To Cancel Buzz Zones 34 14 Chime Zones 36 14 1 To Program the Chime Zones 36 14 2 To Cancel the Chime Zones 38 15 LCD Keypad Menu Navigation 39 15 1 Main Menu 39 15...

Page 5: ...ime to reach the keypad after entering the armed premises This zone is generally the last exit point of the building and the first entry point i e the front door of a home Follower A zone that may be...

Page 6: ...the installer or service professional to have access to the control panel 1 1 Notes Read the entire manual carefully and keep it in an accessible place Your security system should be installed and se...

Page 7: ...n E y a l e D 2 AWAY Indicator Red d e t a n i m u l l I e d o M y a w A n i d e m r A m e t s y S d e h s i u g n i t x E e d o M y a t S d e m r a s i D m e t s y S 3 TROUBLE Indicator Red d e t a...

Page 8: ...ng the LCD display and indicator status will accompany the text directions for the LED keypad Where procedures vary between the keypads the directions and illustrations for the LCD keypad procedure wi...

Page 9: ...f the zones are violated when attempting to arm the system To indicate a trouble condition During the entry exit delay Will sound for 2 seconds when a chime zone is violated 4 System Information 4 1 P...

Page 10: ...r e s U o N e d o C r e s U e m a N r e s U s n o i t i t r a P 1 2 3 4 5 6 7 8 1 0 4 3 2 1 e d o C r e t s a M t l u a f e D X X X X X X X X 1 0 e d o C r e t s a M w e N 2 0 3 0 4 0 5 0 6 0 7 0 8 0...

Page 11: ...2002 VER 2 17 11 IDS1600 USER MANUAL r e s U o N e d o C r e s U e m a N r e s U s n o i t i t r a P 1 2 3 4 5 6 7 8 3 3 4 3 5 3 6 3 7 3 8 3 9 3 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 0 5 1 5 2 5 3...

Page 12: ...y r t n E y r a d n o c e S 2 n o i t i t r a P e h T s d n o c e s s i y a l e D t i x E 2 n o i t i t r a P e h T s d n o c e s s i y a l e d y r t n E y r a m i r P 3 n o i t i t r a P e h T s d n...

Page 13: ...l e d y r t n E y r a d n o c e S 8 n o i t i t r a P e h T s d n o c e s s i y a l e D t i x E 8 n o i t i t r a P e h T s d n o c e s 5 Arming the System There are various options for arming the sys...

Page 14: ...his function is enabled it is possible to AWAY arm by simply holding down the 1 key until the keypad buzzer sounds and the arming process begins 5 3 StayArming USER CODE Do not leave premises This all...

Page 15: ...cator will remain extinguished 0 1 0 1 9 9 0 0 4 S T A Y A R M E D MO N M R A E L B U O R T 8 Any STAY zones shown by a steadily illuminated indicator will be automatically bypassed 9 Ensure that you...

Page 16: ...ure to leave only via the follower and entry exit zones 5 6 Arming a Partition from a Master Keypad Hold down MODE PARTITION NUMBER USER CODE 1 Hold down the MODE key on a master keypad until the keyp...

Page 17: ...NOTE If a remote control is used it is advisable to have the siren sound on arm and disarm function enabled 5 8 Auto Arming Your system can be programmed to automatically arm itself daily at a prepro...

Page 18: ...arming 6 1 To Bypass a Zone Hold down 9 ZONE NUMBER 1 Hold down the 9 key until the keypad buzzer sounds to enter bypass mode 2 Press the number corresponding to the zone you need to by pass e g the 2...

Page 19: ...O B Y P A S S M R A E L B U O R T 4 Press to bypass the zone Z O N E 3 T O D E S E L E C T M R A E L B U O R T 5 Repeat steps 3 and 4 to bypass any other zones 6 Press to exit the bypass mode Z O N E...

Page 20: ...9 key until the keypad buzzer sounds to enter bypass mode 2 Press the number corresponding to the currently bypassed zone then press the key 3 The zone indicator will extinguish the zone is now active...

Page 21: ...R T 5 Repeat steps 3 and 4 to un bypass any other zones 6 Press to exit the bypass mode Z O N E M E N U M R A E L B U O R T 7 Press to exit the zone menu M A I N M E N U M R A E L B U O R T 8 Press t...

Page 22: ...de Once the system disarms the ARMED indicator will extinguish and the keypad buzzer will stop sounding If no valid user code has been entered by the end of the entry delay period an alarm condition w...

Page 23: ...to verify if this feature is enabled 1 Press the remote button or twist and release the key switch 2 The system will disarm and the remote indicator if installed will extinguish 3 If programmed to do...

Page 24: ...period Ensure that your installer has enabled this function if it is required Press this key only in an emergency situation that requires response by emergency personnel 8 3 Medical Alarm M Hold down...

Page 25: ...Memory displays any zones which were violated or bypassed the last time the system was armed If the ARMED indicator is flashing before you disarm the system a violation has occurred To view which zone...

Page 26: ...is valid in the current partition 1 Hold down the key until the keypad buzzer sounds 2 The ARMED and READY indicators will flash alternately indicating that the system is in the mode which allows prog...

Page 27: ...2 Press 3 to enter the User Code Menu E N T E R M A S T E R C O D E M R A E L B U O R T 3 Enter the MASTER USER CODE the factory default is 1234 followed by the key C O D E N U M B E R M R A E L B U...

Page 28: ...s LCD Keypad Follow steps 1 8 of the procedure in 11 1 1 but only press the key in step 5 That particular code will be deleted 12 Stay Zones Stay zones are those zones which are bypassed automatically...

Page 29: ...xit the stay zone programming mode 12 1 1To Program Stay Zones LCD Keypad 1 Hold down the 3 key until the keypad buzzer sounds S T A Y Z O N E MO D E M R A E L B U O R T 2 Press the MODE menu key Z O...

Page 30: ...programmed as a STAY zone will no longer be violated during STAY arming then the STAY status of such a zone should be cancelled This will allow the system to protect that area during a stay arm cycle...

Page 31: ...DE menu key Z O N E 1 F O R S T A Y Z O N E M R A E L B U O R T 3 Use the MODE menu and Fire menu keys to scroll to the stay zone you wish to cancel e g zone 3 Z O N E 3 T O D E S E L E C T M R A E L...

Page 32: ...is advisable to program Buzz zones if you are likely to accidentally trigger these zones or if you have pets This feature helps prevent unnecessary false alarms 13 1To Program Buzz Zones 4 ZONE NUMBER...

Page 33: ...nu key Z O N E 1 F O R B U Z Z Z O N E M R A E L B U O R T 3 Use the MODE menu and Fire menu keys to scroll to the zone you wish to be a buzz zone e g zone 3 Z O N E 3 F O R B U Z Z Z O N E M R A E L...

Page 34: ...O R T 13 2 To Cancel Buzz Zones 1 Repeat the above procedure and ensure that the zone indicator is extinguished When in Buzz zone programming mode use of a ZONE NUMBER the followed by key will toggle...

Page 35: ...E C T M R A E L B U O R T 4 Press the key to cancel the buzz zone Z O N E 3 F O R B U Z Z Z O N E M R A E L B U O R T 5 Repeat steps 3 and 4 until required buzz zones are cancelled 6 Press to exit th...

Page 36: ...s programmed as a chime zone 14 1 To Program the Chime Zones 2 ZONE NUMBER 1 Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash to show that the panel is In the chime z...

Page 37: ...M E Z O N E M R A E L B U O R T 4 Press the key to make the zone a chime zone Z O N E 3 T O D E S E L E C T M R A E L B U O R T 5 Repeat steps 3 and 4 until chime zones are selected 6 Press to exit t...

Page 38: ...zone followed by the key 4 Press the key to exit the chime programming mode 14 2 1To Cancel the Chime Zones LCD Keypad 1 Hold down the 2 key until the keypad buzzer sounds C H I M E MO D E M R A E L...

Page 39: ...0 1 0 1 9 9 0 0 4 R E A D Y MO N M R A E L B U O R T 15 LCD Keypad Menu Navigation 15 1 Main Menu 1 To enter the Main Menu hold down the key until the keypad buzzer sounds 2 Use the MODE menu and Fire...

Page 40: ...and Time 5 Stay Arm 6 Stay Arm Go 7 Reset Fire Sensor 8 Answer Phone To Exit Menu View Menu Zone Menu 3 Bypassed Zones 0 Alarm Memory 1 Trouble 2 Violations 0 Chime Zones 1 Stay Zones 2 Buzz Zones 3 B...

Page 41: ...ator will flash See page 43 for additional information on viewing trouble conditions 15 2 3Violations This menu options allows the user to view the currently violated zones 15 2 4Bypassed Zones This m...

Page 42: ...during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alarm condition It is advisable to program Buzz zones if you are...

Page 43: ...e user to arm the perimeter zones while disabling the interior zones so that it is possible to remain on the premises 15 8 Stay Arm Go Shortcut key 6 This function allows the user to STAY arm and leav...

Page 44: ...ter five seconds To clear the trouble condition press within 5 seconds of viewing e n o Z n o i t i d n o C e l b u o r T 1 k c o l c t s o L 2 e t a c i n u m m o c o t e r u l i a F 3 l i a f C A 4...

Page 45: ...via a follower and entry exit zone or have strayed into an instant zone Either avoid these zones or ask your installer to change the zone type 16 3 Problems when disarming the system Does the siren s...

Page 46: ...3 Stay Arm Go 5 9 15 40 43 Away Mode 7 15 B Bypass 5 7 13 15 16 17 18 19 20 25 28 40 43 44 45 D Disarm 5 7 17 21 22 23 25 41 45 Duress Code 24 E Emergency Evacuation Plan 25 Engineer Reset 44 Entry Ex...

Page 47: ...Fire Sensor 40 43 S Siren 9 17 22 23 24 45 Time Out 23 24 T Time 40 43 Trouble Condition 7 9 41 44 U User Code 10 11 12 13 14 15 16 17 21 22 23 24 26 27 28 28 40 41 43 44 45 Z Zone Buzz 9 29 32 33 34...