background image

January 2020 

 

                                                                                                                                        3

Technical Manual: GigE uEye CP Rev. 2

1 Preface

Introduction

IDS Imaging Development Systems GmbH has taken every possible care in preparing this manual. We
however assume no liability for the content, completeness or quality of the information contained therein. The
content of this manual is regularly updated and adapted to reflect the current status of the software. We
furthermore do not guarantee that this product will function without errors, even if the stated specifications are
adhered to.

Under no circumstances can we guarantee that a particular objective can be achieved with the purchase of
this product.

Insofar as permitted under statutory regulations, we assume no liability for direct damage, indirect damage or
damages suffered by third parties resulting from the purchase of this product. In no event shall any liability
exceed the purchase price of the product.

Please note that the content of this manual is neither part of any previous or existing agreement, promise,
representation or legal relationship, nor an alteration or amendment thereof. All obligations of IDS Imaging
Development Systems GmbH result from the respective contract of sale, which also includes the complete and
exclusively applicable warranty regulations. These contractual warranty regulations are neither extended nor
limited by the information contained in this manual. Should you require further information on this product, or
encounter specific problems that are not discussed in sufficient detail in the manual, please contact your local
dealer or system installer.

Trademarks

The IDS logo is a registered trademark of IDS Imaging Development Systems GmbH,
registered for U.S. (Reg.No. 4,513,138) and other countries.

IDS NXT

 and 

uEye

 are registered trademarks of IDS Imaging Development Systems

GmbH. Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation. All other
products or company names mentioned in this manual are used solely for purposes of identification or
description and may be trademarks or registered trademarks of the respective owners.

Copyright

© IDS Imaging Development Systems GmbH. All rights reserved. This manual may not be reproduced,
transmitted or translated to another language, either as a whole or in parts, without the prior written permission
of IDS Imaging Development Systems GmbH.

Status: January 2020

Contact

Visit our web site 

https://en.ids-imaging.com

 where you will find all the latest information about our software

and hardware products. Please contact your local IDS distributors for first level support in your language. For
a list of IDS distributors worldwide please go to our website 

https://en.ids-imaging.com

.

Address

IDS Imaging Development Systems GmbH
Dimbacher Str. 6-8
D-74182 Obersulm, Germany

T

+49 7134 96196-0

E

[email protected]

W

https://en.ids-imaging.com

Summary of Contents for GigE uEye CP Rev. 2

Page 1: ...GigE uEye CP Rev 2 IDS Imaging Development Systems GmbH Dimbacher Str 6 8 D 74182 Obersulm Germany T 49 7134 96196 0 E info ids imaging com W https en ids imaging com Technical Manual...

Page 2: ...CP Rev 2 9 6 Mechanical specifications 10 7 Optical specifications 11 7 1 Immersion depth for lenses 11 7 2 Position accuracy of the sensor 12 8 Electrical specifications 13 8 1 Pin assignment GigE c...

Page 3: ...nor limited by the information contained in this manual Should you require further information on this product or encounter specific problems that are not discussed in sufficient detail in the manual...

Page 4: ...s This symbol indicates hints with useful information for better understanding and using features and functions This symbol indicates important warnings for product safety to prevent damage This symbo...

Page 5: ...t touch the printed circuit board while it is powered Always hold the board by the edges to avoid the risk of electrostatic discharge damage For optimum ESD behavior a clearance of 4 mm from non shiel...

Page 6: ...on de s curit LPS source puissance limit e ou ES1 PS2 Pour garantir la s curit lectrique nous recommandons l utilisation d un c ble de connexion blind ou la mise la terre du bo tier de la cam ra afin...

Page 7: ...ation for Canada Renseignements pour le Canada CAN ICES 3 A NMB 3 A Information for UL To be compliant with the UL safety criteria GigE cameras must be operated with indoor networks only UL 62368 1 CA...

Page 8: ...dity 20 80 relative non condensing Non condensing means that the relative air humidity must be below 100 Otherwise moisture will form on the camera surface If for example air has a relative humidity o...

Page 9: ...ata network and the camera network should be cabled separately Therefore it is recommend connecting the cameras by a separate network card It is recommend to use Cat5e type cables The cable length of...

Page 10: ...ch camera model can be found on our website directly at the respective camera model beneath in the Downloads tab Fig 1 GigE uEye CP Rev 2 NOTICE The camera connectors may be damaged if you install or...

Page 11: ...into the camera flange the immersion depths are specified based on the diameter named as A B and C in the image below Beside the immersion depth also the back focal length has to be considered that m...

Page 12: ...of the sensor 1 Fig 4 Position accuracy of the sensor 2 It cannot be guaranteed that the sensor cover glass or filter glass are absolutely parallel to each other C mount lenses can also be subject to...

Page 13: ...utside plant 8 1 Pin assignment GigE connector RJ45 8 pin RJ45 socket Pin Designation 100BASE TX Designation 1000BASE T Fig 5 RJ45 socket camera rear view 1 Tx Bl_DA 2 Tx Bl_DA 3 Rx Bl_DB 4 Bl_DC 5 Bl...

Page 14: ...an external source and via Power over Ethernet PoE The camera should not be supplied through both voltage sources at once as this can irreparably damage the camera Keep in mind that a voltage drop wi...

Page 15: ...continuous IC 150 mA The digital output is galvanically isolated using an optocoupler to protect the camera and the PC against surges Only DC voltages may be applied to the digital output The output o...

Page 16: ...January 2020 16 Technical Manual GigE uEye CP Rev 2 Fig 8 Wiring of the digital output as an open collector output Fig 9 Wiring of the digital output as an open emitter output...

Page 17: ...ymbol Min Typ Max Unit IO voltage range VCCIO 0 3 3 V Input high range VIH 1 7 3 3 V Input low range VIL 0 3 0 8 V Input leakage current II A Output high range VOH 3 15 V Output low range VOL 0 2 V Ou...

Page 18: ...January 2020 18 Technical Manual GigE uEye CP Rev 2 GPIO wiring as output Fig 11 GPIO wiring as output 1 Fig 12 GPIO wiring as output 2...

Page 19: ...anual GigE uEye CP Rev 2 9 Status LED Fig 13 Status LEDs The camera has a two color LED that indicates information on the current status Camera is off no power Camera is booting Camera is ready Camera...

Page 20: ...e DL The filter type is given at the end of the model name The following table shows an overview of the different optical filters used in IDS cameras Filter type Name Refractive index nFilter Glass ty...

Page 21: ...or professional cleaning IDS Imaging Development Systems GmbH is not liable for any damage resulting from cleaning the filter glasses This even applies if the following instructions have been observed...

Page 22: ...s Only add small quantities of alcohol to the wipe Never pour alcohol directly onto the camera NOTICE Never use cleaning agents containing acetone for cleaning the filter glasses Acetone may damage th...

Page 23: ...17 H Housing version 10 I I O connector 13 Immersion depth lens 11 Immunity 7 Infrared cut filter 20 Input digital 14 L Linux 9 N Network cable 9 card 9 Network adapter 9 O Operating system Linux 9 W...

Reviews: