IDS 860-06-0005 Manual Download Page 2

IDS  Two  Channel  Remote  Receiver 

IDS  Two  Channel  Remote  Receiver 

IDS  Two  Channel  Remote  Receiver 

6.   Programming the Unit in Stand-Alone

 

Mode. (Power Up Settings)

 

N.B. to change any settings on the receiver unit, the

 

receiver  needs  to  be  powered  down,  the  settings 
changed and then powered up again.

 

 

Restoring the Factory Default Settings:

 

1.    Remove power from the unit by removing jumper 

J5 and switch all DIP switches OFF. 

2.    Switch DIP switches 1, 5, 6, 7 and 8 ON. 
3.    Restore Power to the Unit by replacing J5. 
4.    Switch DIP Switch 8 OFF. 
5.    Wait for the LEDís to start flashing alternately. 
6.    Switch ALL Dip switches OFF. 
7.    When  the  LEDís  stop  flashing  the  unit  is  in  the 

normal operating mode. 

 

The factory default settings with all Dip switches

 

OFF and all jumpers ON are as follow: 

Three Minute Retrigger Protect 

Off 

Remote Learn 

Off 

Panic Remote Learn 

Off 

RF Device Learn 

Off 

Ambient Noise Level Test 

Off 

Device Failure Relay 

Disabled 

Panic Relay 

Enabled 

3 Sec Remote Panic 
 

Enabled 

Relays 
 

Pulse 

Relay 4 Output 
 

Selected 

Power Jumper 

On 

Relay Pulse Period 

3 Sec 

Relays Safe / Secure 
 

Secure 

Panic Relay 

Relay 4 

RF Device Output Relay 

None 

Remote Button Outputs 

Button 1 

Relay 1 

3 Sec Hold for Panic Button 

All 

Relay 3 Min Retrigger Protect 

 None 

Signal Jamming Detect Period 

 30s 

Device Not Reporting 

1hr max 

 

Deleting ALL the User Remotes:

 

1.    Remove power from the unit by removing jumper

J5 and switch all DIP switches OFF. 

2.    Switch DIP switches 2, 5, 6, 7 and 8 ON. 
3.    Restore Power to the Unit by replacing J5. 
4.    Switch DIP Switch 8 OFF. 
5.    Wait for the LEDís to start alternating. 
6.    Switch ALL DIP switches OFF. 
7.    When  the  LEDís  stop  flashing  the  unit  is  in  the 

normal operating mode. 

 

Deleting ALL Supervised RF Devices

 

(e.g. RF Passive IR’s):

 

1.    Remove power from the unit by removing jumper

J5 and switch all DIP switches OFF. 

2.    Switch DIP switches 3, 5, 6, 7 and 8 ON. 
3.    Restore Power to the Unit by replacing J5. 
4.    Switch DIP Switch 8 OFF. 
5.    Wait for the LEDís to start flashing alternately. 
6.    Switch ALL DIP switches OFF. 
7.    When  the  LEDís  stop  flashing  the  unit  is  in  the 

normal operating mode. 

 

Adjusting the Relay Pulse Periods:

 

1.    Remove power from the unit by removing jumper

J5 and switch all DIP switches OFF. 

2.    Switch DIP switches 7 and 8 ON. 
3.    Restore Power to the Unit by replacing J5. 
4.    To adjust relay 1ís pulse period, switch DIP switch

1 ON.* 

5.    Wait for as long as the pulse needs to be (Up to

10 minutes). 

6.    Switch  DIP  switch  1  OFF  (For  relay  1ís  pulse 

period). 

7.    Switch DIP switch 8 OFF. 
8.    Wait for the LEDís to start flashing alternately. 

9.    Switch ALL DIP switches OFF. 
10.  When  the  LEDís  stop  flashing  the  unit  is  in  the 

normal operating mode. 

 

Changing Between Relay Safe and Secure Modes:

1.    Remove power from the unit by removing jumper

J5 and switch all DIP switches OFF. 

2.    Switch DIP switches 6 and 8 ON. 
3.    Restore Power to the Unit by replacing J5. 
4.    To  make  Relay  1  and  4  Fail  Safe,  switch  DIP 

switches 1 and 4 ON.* (Any relay not selected will 
be Fail Secure.) 

5.    Switch DIP switch 8 OFF. 
6.    Wait for the LEDís to start flashing alternately. 
7.    Switch ALL DIP switches OFF. 
8.    When  the  LEDís  stop  flashing  the  unit  is  in  the 

normal operating mode. 

 

Selecting the Panic Relay Output:

 

1.    Remove power from the unit by removing jumper

J5 and switch all DIP switches OFF. 

2.    Switch DIP switches 6, 7 and 8 ON. 
3.    Restore Power to the Unit by replacing J5. 
4.    Select the relay to be the Panic Relay.* (If no relay 

is selected, the panic relay will be disabled.) 

5.    Switch DIP switch 8 OFF. 
6.    Wait for the LEDís to start flashing alternately. 
7.    Switch ALL DIP switches OFF. 
8.    When  the  LEDís  stop  flashing  the  unit  is  in  the 

normal operating mode. 

 

 

* * 

Where indicated DIP switch 1 represents Relay 1, 
DIP switch 4 represents Relay 4.

 

IDS 

IDS 700-284-5 AUG 2005  VER 1.40

IDS

IDS 

6

 