6. Programming the Unit in Stand-Alone
Mode. (Power Up Settings)
N.B. to change any settings on the receiver unit, the
receiver needs to be powered down, the settings
changed and then powered up again.
Restoring the Factory Default Settings:
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 1, 5, 6, 7 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Switch DIP Switch 8 OFF.
5. Wait for the LEDís to start flashing alternately.
6. Switch ALL Dip switches OFF.
7. When the LEDís stop flashing the unit is in the
normal operating mode.
The factory default settings with all Dip switches
OFF and all jumpers ON are as follow:
Three Minute Retrigger Protect
Off
Remote Learn
Off
Panic Remote Learn
Off
RF Device Learn
Off
Ambient Noise Level Test
Off
Device Failure Relay
Disabled
Panic Relay
Enabled
3 Sec Remote Panic
Enabled
Relays
Pulse
Relay 4 Output
Selected
Power Jumper
On
Relay Pulse Period
3 Sec
Relays Safe / Secure
Secure
Panic Relay
Relay 4
RF Device Output Relay
None
Remote Button Outputs
Button 1
Relay 1
3 Sec Hold for Panic Button
All
Relay 3 Min Retrigger Protect
None
Signal Jamming Detect Period
30s
Device Not Reporting
1hr max
Deleting ALL the User Remotes:
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 2, 5, 6, 7 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Switch DIP Switch 8 OFF.
5. Wait for the LEDís to start alternating.
6. Switch ALL DIP switches OFF.
7. When the LEDís stop flashing the unit is in the
normal operating mode.
Deleting ALL Supervised RF Devices
(e.g. RF Passive IR’s):
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 3, 5, 6, 7 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Switch DIP Switch 8 OFF.
5. Wait for the LEDís to start flashing alternately.
6. Switch ALL DIP switches OFF.
7. When the LEDís stop flashing the unit is in the
normal operating mode.
Adjusting the Relay Pulse Periods:
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 7 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. To adjust relay 1ís pulse period, switch DIP switch
1 ON.*
5. Wait for as long as the pulse needs to be (Up to
10 minutes).
6. Switch DIP switch 1 OFF (For relay 1ís pulse
period).
7. Switch DIP switch 8 OFF.
8. Wait for the LEDís to start flashing alternately.
9. Switch ALL DIP switches OFF.
10. When the LEDís stop flashing the unit is in the
normal operating mode.
Changing Between Relay Safe and Secure Modes:
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 6 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. To make Relay 1 and 4 Fail Safe, switch DIP
switches 1 and 4 ON.* (Any relay not selected will
be Fail Secure.)
5. Switch DIP switch 8 OFF.
6. Wait for the LEDís to start flashing alternately.
7. Switch ALL DIP switches OFF.
8. When the LEDís stop flashing the unit is in the
normal operating mode.
Selecting the Panic Relay Output:
1. Remove power from the unit by removing jumper
J5 and switch all DIP switches OFF.
2. Switch DIP switches 6, 7 and 8 ON.
3. Restore Power to the Unit by replacing J5.
4. Select the relay to be the Panic Relay.* (If no relay
is selected, the panic relay will be disabled.)
5. Switch DIP switch 8 OFF.
6. Wait for the LEDís to start flashing alternately.
7. Switch ALL DIP switches OFF.
8. When the LEDís stop flashing the unit is in the
normal operating mode.
* *
Where indicated DIP switch 1 represents Relay 1,
DIP switch 4 represents Relay 4.
IDS
IDS 700-284-5 AUG 2005 VER 1.40
IDS
IDS
4
5
6