background image

APPENDIX

 C  CONFORMITY TO EUROPEAN and UK REGULATIONS

 

Mod: MDM/011/M2 Rev 8

 

IDS GeoRadar Srl 

MNG/2022/007   Rev. 1.0

 

33/ 36 

APPENDIX C

 

 CONFORMITY TO EUROPEAN and UK 
REGULATIONS 

 

 
 

 
 
 

 

 

 

EC DECLARATION OF CONFORMITY 

We,   

IDS Georadar s.r.l. 
via A. Righi, 

 

6, 6 A, 8, 56121 PISA, ITALY 

 
declare under our sole responsibility that the product 
 

Ground Penetrating Radar (GPR) 
Model No(s): AE32HV

 

 

To which this declaration relates, is in conformity with the essential requirements of 
 

2014/53/EU Directive (RED) 

 
The product(s) has been tested according to the following standards or technical specifications:  
 

 

Essential requirements 

Standard 

Essential requirements for the protection of the 
health and safety of people, pets and goods, Article 
3.1a) 

- Assessment for conformity to Art. 3.1a (Safety) 
- Assessment for conformity to Art. 3.1a (Health) 

Essential requirements on electromagnetic 
compatibility levels, Article 3.1b) 

ETSI EN 301 489-33 V2.2.1 (2019-04) 
ETSI EN 301 489-1 V2.2.3 (2019-11) 

Essential requirements for the effective use of radio 
spectrum, Article 3.2 

ETSI EN 302 066 V2.2.1 (2020-06) 
ETSI TS 103 361 V1.1.1(2016-03) 

 

 
 

 
 

Issued on: 2022,  July the 25

th

       

 
 

(Signature):        

 
 
(Printed Name):  Guido Manacorda  
 
(Title):                 R&D Manager             

 

 

UKCA DECLARATION OF CONFORMITY 

We,   

IDS Georadar s.r.l. 
via A. Righi, 

 

6, 6 A, 8, 56121 PISA, ITALY 

 
declare under our sole responsibility that the product 
 

Ground Penetrating Radar (GPR) 
Model No(s): AE32HV

 

 

To which this declaration relates is in conformity with the relevant legislation of United Kingdom: 
 

UK SI 2017 No. 1206 The Radio Equipment Regulation 2017 

 
The following BSI standards and technical specifications have been applied: 
 
standard(s) or other normative document(s) 
 

Essential requirements 

Standard 

Radio Testing (UK Part 2 Chapter 1(6)(2)) 

ETSI EN 302 066 V2.2.1 (2020-06) 
ETSI TS 103 361 V1.1.1(2016-03) 

EMC testing (UK Part 2 Chapter 1(6)(1)(b) 

ETSI EN 301 489-33 V2.2.1 (2019-04) 
ETSI EN 301 489-1 V2.2.3 (2019-11) 

Safety testing (UK Part 2 Chapter 1(6)(1)(a)) 

- Assessment for conformity to UK Part 2 Chapter 
1(6)(1)(a) (Safety) 
- Assessment for conformity to UK Part 2 Chapter 
1(6)(1)(a) (Health) 

 

 
 
 
 
 
 
 
 

 

 
 
 
 

Issued on: 2022,  July the 25

th

       

 
 

(Signature):        

 
 
(Printed Name):  Guido Manacorda  
 
(Title):                 R&D Manager             

 

Summary of Contents for STREAM DP

Page 1: ...IDS Geo MNG 2022 007 Rev 1 0 June 2022 User Manual ORIGINAL INSTRUCTION IN ENGLISH LANGUAGE STREAM DP using GPR AE32HV User Manual Installation and use User Manual...

Page 2: ...STREAM DP User Manual Rev 1 0 User Manual Mod MDM 011 M2 Rev8 IDS GeoRadar Srl MNG 2022 007 Rev 1 0 2 36...

Page 3: ...to changed circumstances or other information which may affect the accuracy of any information contained in this version of the Manual About the Product All products designed produced and distributed...

Page 4: ...TION 10 3 2 INTENDED USE 10 3 3 REASONABLY FORESEEABLE MISUSE 10 3 4 LIMITS OF USE 10 3 5 RESPONSIBILITIES 10 3 6 HAZARD OF USE 12 4 GENERAL DESCRIPTION OF THE HARDWARE 15 4 1 E S T EQUALIZED SCRAMBLE...

Page 5: ...SSEMBLING THE SYSTEM 26 7 CARE AND TRANSPORT 28 7 1 CLEANING INFORMATION 28 7 2 BATTERY REMOVAL INFORMATION 28 7 3 PERIODICAL CHECK 28 7 4 TRANSPORT OF THE SYSTEM 29 APPENDIX A DISCLAIMER 30 APPENDIX...

Page 6: ...are the technician s in charge of using the system that has undergone the IDS GeoRadar training for Stream DP 1 4 Authorization of use The use of STREAM DP system may be subject to a license and or a...

Page 7: ...t This is a Class A product In a domestic environment it may cause radio interference If so the user may need to take adequate measures 1 4 2 UKCA Marking This equipment complies with the essential re...

Page 8: ...eral rules of behaviour For the user s safety all safety instructions and safety messages shall be strictly observed and followed Therefore the manual must always be available to all persons performin...

Page 9: ...n the controller EST Equalized Scrambled Technology GNSS Global Navigation Satellite System GPR Ground Penetrating Radar or Georadar or Ground Probing Radar HMI Human Machine Interface HW Hardware NME...

Page 10: ...of Use Environment Suitable for use in an atmosphere appropriate for permanent human habitation Not suitable for use in explosive environments WARNING POTENTIALLY HAZARDOUS AREAS working in hazardous...

Page 11: ...atch out for erroneous measurement results if the product has been dropped or has been misused modified stored for long periods Precautions Periodically carry out test measurements particularly after...

Page 12: ...t is essential to work in this environment first contact the safety authorities responsible for the electrical installations and follow their safety instructions WARNING If the product is used with ac...

Page 13: ...f the following can happen If polymer parts are burnt poisonous gases are produced which may impair health If batteries are damaged or are heated strongly they can explode and cause poisoning burning...

Page 14: ...battery terminals If battery terminals are short circuited e g by coming in contact with jewellery keys metallised paper or other metals the battery can overheat and cause injury or fire for example...

Page 15: ...in transverse polarization The antenna integrates the radar control unit FCU Fast Control Unit that manages all the input and output It is directly connected to the laptop and powered by two Li Ion ba...

Page 16: ...d MDM 011 M2 Rev 8 IDS GeoRadar Srl MNG 2022 007 Rev 1 0 16 36 Fig 1 Stream DP Rugged configuration Fig 2 Stream DP Asphalt configuration Stream DP dimensions are reported on the following pictures Fi...

Page 17: ...4 GENERAL DESCRIPTION OF THE HARDWARE Mod MDM 011 M2 Rev 8 IDS GeoRadar Srl MNG 2022 007 Rev 1 0 17 36 Fig 4 Stream DP rear view...

Page 18: ...ntenna module Laptop with uMap data acquisition software Battery Battery charger GPS support Vehicle Towing kit accessory This chapter contains a description of the above listed parts The whole system...

Page 19: ...port for accessories Power out PWR enables the power supply on Stream DP accessories Synchronism and Positioning SYNC transfer PPS and wheel data to an external device or receive external PPS as inpu...

Page 20: ...ur wheeled system and the wheels are available in two configurations 2 pivoting wheels Fig 10 and 2 fixed wheels standard Bill of Materials All fixed wheels Fig 10 Pivot vs Fixed wheels Pivoting wheel...

Page 21: ...le handle Stream DP handle is ergonomic and adjustable in two positions Two pins fasten the upper part of the handle Fig 12 users can easily remove them by pressing the quick release button and then c...

Page 22: ...S support pole can be extended up to 2 meters by unscrewing the plastic bushing Fig 14 and pressing the plastic buttons on the pole Fig 15 Fig 14 Removing the plastic bushing Fig 15 Plastic lock The t...

Page 23: ...e the width of the tablet enclosure Then the user can insert the tablet and release the right part to secure the tablet Fig 18 Fig 18 Data logger support The support includes the tablet cradle to hold...

Page 24: ...n body Fig 21 Wheel button 2 Place the antenna on a horizontal surface move the frame over the antenna by fitting the frame in the antenna s inserts 3 Secure the antenna to the lifting system fastenin...

Page 25: ...Srl MNG 2022 007 Rev 1 0 25 36 9 Connect two wheel cables and turn to fasten Fig 23 10 Connect the LAN cable from the antenna to the tablet port Fig 23 Fig 23 Connection overview 11 Turn the system o...

Page 26: ...order to fold the handle the user has to remove only the two front pins on the main frame Fig 25 Fig 25 How to fold the handle Now it s possible to close the rudder Fig 26 Fig 26 Transportation mode 6...

Page 27: ...6 HOW TO SET UP THE STREAM DP IN TRANSPORT MODE Mod MDM 011 M2 Rev 8 IDS GeoRadar Srl MNG 2022 007 Rev 1 0 27 36 Fig 27 Ergonomic slot one operator Fig 28 Ergonomic slots two operators...

Page 28: ...vents or abrasive detergents Do not apply liquid directly to the electrical contacts of the various connectors If a specific spray is used to clean the PC monitor make sure it is not flammable in any...

Page 29: ...TICE All the connectors on top of the SCU the antennas the accessories must be plugged at any time either by the corresponding cable plug or by the connector cap when not in use This is to prevent dus...

Page 30: ...indirect special incidental or consequential damages or injuries including without limitation lost revenues or lost profits resulting by un authorized use of the Products in Public Areas Roads iii Bu...

Page 31: ...of IDS GeoRadar S r l d Unauthorized changes and additions to the Products e Use of the Products connected to suspected non working equipment or with equipment mainly PC having characteristics not in...

Page 32: ...ility Environmental IP65 Max Acquisition Speed 14km h 8 7 mph Positioning Integrated Encoder and PPS external GPS and TPS Certificaton EC FCC IC UKCA Recommended Laptop Panasonic FZ G2 SOFTWARE SPECIF...

Page 33: ...ents for the effective use of radio spectrum Article 3 2 ETSI EN 302 066 V2 2 1 2020 06 ETSI TS 103 361 V1 1 1 2016 03 Issued on 2022 July the 25th Signature Printed Name Guido Manacorda Title R D Man...

Page 34: ...the FCC ID number and other nomenclature of the UWB device This material shall be submitted to the following address Frequency Coordination Branch OET Federal Communications Commission 445 12th Street...

Page 35: ...ot cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device NOTE IMPORTANTE POUR LES UTILISATEURS CANADIENS Num ro de certi...

Page 36: ...r Support team is available to answer any question about general enquiries request of advertising material technical issues As well as listening to your suggestions too Please feel free to contact us...

Reviews: