background image

GB

Operator’s Manual

Distributed by Australian Pump Industries (02) 8865 3500

From serial number 
1121001 onwards

Summary of Contents for Stella 1000-100/11

Page 1: ...GB Operator s Manual Distributed by Australian Pump Industries 02 8865 3500 From serial number 1121001 onwards...

Page 2: ...ing the gun open Wait for steady pressure 2 Wind BY PASS valve down to lowest setting reduces flow to minimum 3 Turn thermostat to required STEAM setting 4 Do not release the gun trigger when working...

Page 3: ...pag 42 5 2 Inactivity pag 42 5 3 Transport pag 43 5 4 Halding pag 43 5 5 Standard equipment pag 43 5 6 Installation and connection pag 43 5 7 Cleaning and disinfecting pag 45 5 8 Reinstallation and re...

Page 4: ...7 9 Emergency stop pag 51 7 10 Resetting conditions pag 51 7 11 Storage operation pag 52 8 Maintenance pag 53 8 1 Regular maintenance pag 53 8 2 Extraordinary maintenance pag 54 8 3 Technical informat...

Page 5: ...y starts from the date of purchase The valid date of purchase is that indicated on the receipted or invoice issued at the time the equipment is delivered by the retailer IDROBASE undertakes to repair...

Page 6: ...of unauthorized personnel or persons who are not wearing suitable protective garments Although a suitable grip is provided with the lance the water pressure at the start of the discharge from the nozz...

Page 7: ...t may cause serious damage to the high pressure pump WARNING Protective garments should be worm WARNING This manual must be read before using WARNING Only use recommended liquid detergents the use of...

Page 8: ...ainless steel frame equipped with wheels and with a plate on which are fitted the motor pump regulating valve control panel and hoses The heating unit which produces hot water is composed of an electr...

Page 9: ...common sense You should not use the machine if you experience any defects or damage that could compromise the original security the responsible for the installation the user or maitenance technician h...

Page 10: ...chine TECNICAL DATA MODEL Pressure bar Flow rate l min Power Kw Temperature Max C Weight kg 1000 100 11 100 11 2 2 90 160 1000 200 15 200 15 5 5 80 165 OVERALL DIMENSIONS cm A B C 570 1130 890 4 TECHN...

Page 11: ...carried out to conform to all local laws and regulations After having unpacked the machine make sure that the pressure washer is complete including all of the requested accessories 5 2 INACTIVITY Duri...

Page 12: ...ile respecting the normal health and safety regula tions 5 4 HANDLING Always use a fork lift truck to move or handle the machine 5 5 STANDARD EQUIPMENT Check that the packaging contains the following...

Page 13: ...must respond to the rating of the Stella 11 The Stella must be properly connected to an efficient grounded system matching and combined with a circuit breaker with a sensitivity of 30mA in A class 12...

Page 14: ...is recommended that all parts which could be dangerous are rendered safe removing all of the electrical compo nents while conforming to current legislation regarding the scrapping of these materials...

Page 15: ...AND USE GB 1 Do not leave the Stella for more than three continuous minutes in BY PASS 2 Do not leave the Stella in the TOTAL STOP position without the presence of the operator 3 Do not leave the Ste...

Page 16: ...cool down disconnect the electric plug and verify that it complies with the instructions contained in the paragraph Connection and installation of the electricity supply checking the extension lead u...

Page 17: ...t and outlet 6 7 PERSISTENT HAZARDS The pressure washer was designed to eliminate as much as possible any cause of danger when in use however RISK OF BURNS from the heating unit exhaust described in t...

Page 18: ...STAGE position 18 Turn on the burner via the thermostat and position it at the desired temperature 19 During the washing operation with steam do never close the gun 20 The first step to turn off the...

Page 19: ...e use of detergents or disinfectants it is useful to run the machine for a few minutes with clean water to rinse out the circuit WARNING Do not use the pressure washer to suck in any products containi...

Page 20: ...the following sections 7 8 STOPPING OPERATION 1 When using a hot water machine run the pressure washer with cold water for a few minutes by turning the ther mostat to 0 C zero C 2 Completely close th...

Page 21: ...nnot withstand very cold temperatures Do not leave the machine in an enviroment in which the temperature is less than 5 C In case of storage in a cold enviroment with a temperature less than 5 C first...

Page 22: ...plugs are in a good state of repair Verify also that the water hose high pressure hose connections gun and lance are in excellent condition NB If one or more of these components are damaged do not us...

Page 23: ...filter cup pump and nozzle Adjustment or replacement of the electrodes Clean the heater Check the tension in the drive belt Check the pump is securely fixed Check the motor is securely fixed Check th...

Page 24: ...tch off the machine diassemble the nozzle and clean it 3 Check the water supply circuit 4 Check the positioning of the hose or replace it Pressure in the pump is above normal level but the pressure to...

Page 25: ...d in this instruction manual For possible repairs seek advice from the manufacturer 10 2 SPARE PARTS The pressure washer comes delivered with this instruction manual with the spare parts booklet enclo...

Page 26: ...y cutting the power cable It is recommended that the parts that can be dangerous are rendered safe for example remove all electrical parts while following current legislation regarding their disposal...

Page 27: ...ack Blue Black Blue Black Black Nero Marrone Blu Gia llo Bianco 400V 50HZ Thermostat Nero Black P2 High pression pressure switch P1 Pump pressure switch Total stop board Motor Pump H V igniction trans...

Page 28: ...er Caldaia Motore Motor Burner Black Nero Nero Black Marrone Brown Blu Blue Giallo Yellow Bianco White P2 Pres sostato A P Scheda total stop P1 Pres sostato pompa P2 High pression pressure switc h P1...

Page 29: ...by relesing to the identification plato is in accordance with the following Directive 89 336 CEE Directive EMC Directive and subsequent emendaments 73 23 CEE Directive Llow Voltage Directive and subs...

Page 30: ...30 NOTES Distributed by Australian Pump Industries 02 8865 3500...

Page 31: ...31 NOTES Distributed by Australian Pump Industries 02 8865 3500...

Page 32: ...ed firm n 9 190 IDRH 11 02 2005 UNI ES ISO 9001 2000 35010 BORGORICCO PD ITALIA Via Dell Industria 25 Tel 39 049 9335903 Fax 39 049 9335922 E mail idrobase idrobase com www idrobase com Distributed by...

Reviews: