background image

19

Rev. 00 - 04/2014

1 - APPLICATIONS 

The following are excluded from the warranty: accidental damage due to transport, negligence or inap-
propriate  treatment,  incorrect  or  improper  use  or  installation,  i.e.  not  complying  to  the  instruction  ma-
nual,  and  any  situations  that  do  not  depend  on  machine  standards  and  operation,  or  on  electrical  and 
equipment use. The warranty is invalidated if the equipment is repaired or tampered with by unauthorized 
third parties. The equipment shall not be replaced nor the warranty extended after it has been repaired for 
faults. The warranty does not cover cleaning the working parts or replacing consumable components such 
as pump oil, nozzle, etc. 

IDROBASE GROUP SRL is not liable for any damage to persons or objects due 

to incorrect installation or improper use of the equipment.

1.4  

CONDITIONS FOR RETURNS

It will be the responsibility of the end user to return the product to the retailer; or telephone for further 
information to the number 

+39 049 9335136

1.5  

CASES IN WHICH THE MANUFACTURER IS NOT LIABLE

The manufacturer is not liable for damage caused by the following:

 

Improper use of the machine or use by untrained people.

 

Use of non genuine spare parts.

 

Non-compliance with maintenance.

 

Unauthorized modifi cations or operation.

 

Non-observance, in total or part, of the instruction manual.

 

Non-observance, in total or part, of the safety regulation in force in the country where the machine is 
used.

1.6  

SAFETY

The CIELO is well-advanced from a technical point of view and for a proper installation, good operation, 
proper use and maintenance, it needs trained, responsible staff  who has to comply with the following rules 
of safety and conduct.

 

Do NOT

 expose the machine to freeze and the outside weather in general. Freezing can cause severe 

damages to the pump and circuit. The prolonged downtime at temperatures below 0°C (zero Celsius 
degrees) can cause damages or break pump and pipes, it is better to do a complete emptying; 

 

The electrical system connected to the machine 

MUST

 be made in compliance with the laws in force in 

the country of installation;

 

It is 

RECOMMENDED

 the presence of a diff erential circuit breaker, with a sensitivity of 30 mA above the 

socket or power plant;

 

Do NOT

 use extension cords or loose plugs; 

 

The integrity and insulation of the electric cable and equipment 

MUST

 be checked, because the work 

environment is necessarily exposed to water and humidity conditions that preclude the natural system 
insulation;

 

Do 

NOT

 use the machine if the cable is damaged or worn; disconnect the device from the network and 

contact an authorized service center; 

 

You 

MUST 

follow the rules imposed by the Fire Department or by local entrusted bodies. 

 

Do 

NOT

 touch the plug with wet hands or feet! 

 

Avoid accidental operation. You 

MUST

 place the switch OFF before inserting or removing the plug from 

the socket;

 

Do 

NOT

 pull the cord to remove the plug; 

Rev. 00 - 04/2014

Summary of Contents for PerfectCool Cielo

Page 1: ...installing and using the machine impe rative that the installer and the user read and un derstand all parts of this manual The manual is an integral part of the machine and must necessarily be kept fo...

Page 2: ...roved by the fingers IDROBASE GROUP Srl may affect the performance or durabi lity of the machine and create the potential risk to the machine itself or the staff as well as make void the warranty The...

Page 3: ...sentation 2 1 Purpose 22 3 Layout of the manual 3 1 Information 23 4 Electric and hydraulic connection 24 5 Operation and use 5 1 Range of applications 25 5 2 Working limits 25 5 3 Water connection to...

Page 4: ...ed under warranty in accordance with statutory law from manufacturing defects THE WARRANTY IS INVALIDATED IF THE USE OF THE MACHINE DOES NOT CONFORM TO THE IN STRUCTIONS FOR USE CONTAINED IN THIS MANU...

Page 5: ...part of the safety regulation in force in the country where the machine is used 1 6 SAFETY The CIELO is well advanced from a technical point of view and for a proper installation good operation proper...

Page 6: ...put outside good precautions must be taken in order to PREVENT the dangerous effect of weather conditions 1 7 SYMBOLS In this manual the symbols depicted describe important functions of the machine fo...

Page 7: ...THE MACHINE IS LIVE SWITCHED ON ALWAYS DISCONNECT FROM THE ELECTRICAL SUPPLY BEFORE CARRYING OUT REPAIRS OR REMOVING THE COVER WARNING AVOID STORING OR USING THE MACHINE IN EXTREME TEMPERATURES FROST...

Page 8: ...ons are Bar Hotel Restaurantes night club Through the use of suitable optional kits or models for each of these types achieves maximum performance It uses the principle of adiabatic cooling the ambien...

Page 9: ...the machine The user must follow the safety regulations to the country of installation in addition to the rules dictated by common sense You should not use the machine if you note any defects or damag...

Page 10: ...24 Rev 00 04 2014 4 ELECTRIC AND HYDRAULIC CONNECTION 1 2 WATER PIPE ELECTRIC CABLE FROM INSIDE THE BASE CONNECTING 1 1 Rev 00 04 2014 2...

Page 11: ...pump hoses and to the parts in general It is therefore advisable to empty the machine completely For more information contact the retailer or manufacturer 5 3 WATER CONNECTION TO THE MACHINE The mach...

Page 12: ...cording to the instructions in this manual WARNING THE SYSTEM MUST BE USED ONLY BY A TRAINED OPERATOR WHO USES THE MACHINE IN ACCORDANCE WITH THE INSTRUCTIONS CONTAINED IN THIS MANUAL AND OR THE MA NU...

Page 13: ...THE DESTRUCTION OF THE MACHINE MUST BE CARRIED OUT ONLY BY A TRAINED PERSON OR BY A QUALIFIED TECHNICIAN When it has been decided to destroy the machine and render it unusable it is recommended that...

Page 14: ...ry 50 hours the proper functioning of the nozzles of the crown group that could get clogged due to the formation of limestone or using unclean water A nozzle is clogged note because drips or has a spr...

Page 15: ...mmen ded that all parts which could be dangerous are rendered safe removing all of the electrical components while conforming to current legislation regarding the scrapping of these mate rials The var...

Page 16: ...com www perfectcool it www idrotech com www sparesclub com Idrobase Group S r l Via dell Industria 25 35010 BORGORICCO PD ITALY Tel 39 049 9335903 Fax 39 049 9335922 info idrobasegroup com www idroba...