Press  SET  and  UP  key  and  hold  on  for  three  seconds  to  enter  the 

System 

Advanced menu settings

, press the ▲ or ▼ key to select the adjustment menu, 

press SET key once to enter the appropriate parameter settings, press ▲ or ▼ 
to  adjust  the  parameters  needed  to be  modified.  After  being  adjusted,  press 
the RST key to exit, 
 

CODE 

Functional Description

 

RE 

C/F 

Celsius, Fahrenheit selection

 

 

C:

Celsius

, F:

Fahrenheit

 

S

7

 

Conditioning step

 

 

01:

Conditioning step

 0.1

 Degree

 

10:

Conditioning step 

0.5

  Degree

 

DL 

Timer off 

ON:

Open

 

OFF:close(

Some models do not 

have this option

 

) 

Timing mode

 

 

OFF:

Thermostat starts after

 

ON:

Start time after startup 

Some  models  do  not  have  this 

option

 
 

Errors indications:

 

  1) When the sensor disconnected, the screen displays EEE   
  2) When the sensor detects the temperature is below the lowest temperature 
that could be detected, the screen displays LLL. 
  3)  When  the  sensor  detects  a  temperature  higher  than  the  Maximum 
temperature that could be detected, the screen displays HHH.

 

 
Caution for using:

 

 

  Please connect the correct operating voltage, the machine normally works 

under the standard input voltage within range of 

±

  10%. 

  The load power should not exceed the maximum thermostat control power, 

when exceeding please connect external AC contactor. 

  Please connect the power load correctly

 

and the sensor, or it will damage 

the thermostat, when connect the wrong line . 

  Please do not put the sensor lines and power lines in parallel, power line 

noise affects the accuracy of the measurement. 
 