SWC-2000 Command Guide
31
3.2.6 Advanced setting
@GLS / @SLS
Locking/Unlocking Control command button and standby button lock
Function
Getting
Setting
Format
@GLS
@SLS, lock
Return value
@GLS, lock
@SLS, lock
Parameter
lock: Locking/Unlocking control command button and standby button
0 = Unlocking [Default]
1 = Locking
2 = Changing the current setting
Example
@GLS
@GLS,1
Getting the control command buttons and
standby button lock status
Locking
@SLS,1
@SLS,1
Locking the control command buttons
and standby button
Completed
Remarks
You can lock/unlock these buttons by pressing and holding
the “KEYLOCK” button.
@GBZ / @SBZ
Buzzer sound for when pressing buttons
Function
Getting
Setting
Format
@GBZ
@SBZ, bz
Return value
@GBZ, bz
@SBZ, bz
Parameter
bz: Buzzer sound
0 = OFF, 1 = ON [Default]
Example
@GBZ
@GBZ,1
Getting the buzzer sound setting
ON
@SBZ,1
@SBZ,1
Enabling buzzer sound
Completed
Remarks
-
@GIV
Version
Function
Getting
Format
@GIV
Return value
@GIV, id, ver
Parameter
id : Model number
ver : Firmware version
Example
@GIV
@GIV,SWC-2000,1.00
Getting the product information
Model number and firmware version are
replied
Remarks
” is valid, even if the standby button is “OFF”.