10.4 Input setting
10.4.1 Non-signal input monitoring
If EDID of the NJR-T04HD is changed or it is turned ON/OFF, the source device may not output video signal.
In this case, you can set the time length which is from when a source device stops outputting signal to when
the NJR-T04HD requests the source device to output video signal.
[Fig. 10.6] Monitoring absence of input
Setting for
For each HDMI input connector
Setting value
OFF
2 to 15 [second] [Default] 10 [second]
Note:
If you use the monitor power-saving function or Dual monitor function of the PC, set this menu to “OFF”. The
PC that receives output request may cancel those functions.
If you set shorter time than the time the source device outputs video, the source device may not output video.
In such case, set the longer time.
[Fig. 10.7] Repeating reset
Communication command
@SDT Set monitoring time of video
@GDT Get monitoring time of video
NJR-T04HD
EDID is
changed
ON
OFF
Requesting source device
to output video signal
Monitoring time
Hot plug
ON
OFF
Video signal
from source
device
EDID is
changed
Monitoring
time
ON
OFF
Monitoring
time
Monitoring
time
Source device outputs video
Video signal from
source device
Requesting source device to output video signal