![IDK MSD-804FD Series Command Manual Download Page 21](http://html2.mh-extra.com/html/idk/msd-804fd-series/msd-804fd-series_command-manual_3788839021.webp)
MSD-804FD Users Guide (Command Guide)
21
3.3 Settings
For “Related info.” mentioned in each table below, refer to the Users Guide of MSD-804FD.
3.3.1 Error status
@ERR Error
status
Command
format
Only Return value
Return value
format
@ERR,
error
Parameter
error
: Error status
1 = Erroneous parameter format or value
2 = Undefined command or wrong format
3 = Currently unavailable command
5 = The command could not be executed since no command was registered or the
command was not registered.
6 = The command could not process the command since another command was
being executed.
7 = Automatic measurement of input timing failed.
8 = Loading EDID from the display device failed.
10 = The control command was stopped according to the stop condition.
11 = The control command was stopped since the number of retries exceeded the
set value of “RETRY”.
12 = The control command of PJLink was stopped since the password did not match.
13 = The image could not be captured since the image size to be captured exceeded
the reserved memory size.
14 = Capturing input image failed.
15 = Could not be set or collected since Cat5e/Cat6 output option is not installed.
Example Send
Receive
@SSW,999,1
@ERR,1
Parameter error
Send
Receive
@XYZ
@ERR,2
Not defined command
Send
Receive
@RPM,3
@ERR,3
Specified memory number had no data registration