MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
92
@GIT / @SIT
Ineffective time during control command execution
Getting
Command
@GIT
Response
@GIT, time
Setting
Command
@SIT, time
Response
@SIT, time
Parameter
time : Invalid time
0 = 0 sec. to 999999 = 999.999 sec. [Default] 0 sec.
Getting
example
Command
Response
@GIT
@GIT,2000
Description Getting ineffective time of control command execution.
Disabling operation during control command execution or 2000 ms. (2 seconds)
after control command starts.
Setting
example
Command
Response
@SIT,2000
@SIT,2000
Description Setting ineffective time during control command execution to 2000 ms. (2
seconds).
Remarks
-
@DEC
Initializing registered command and link
Setting
Command
@DEC, no_1 (, no_2, no_3
・・・
)
Response
@DEC, no_1 (, no_2, no_3
・・・
)
Parameter
no_1-32: Commands or links you want to initialize
1 to 32: Control commands 1 to 32
101 to 132: Response commands1 to 32 (“1xx”: xx is the response command
number)
【
201 to 255: Control command links1 to 5 (“2xx”: xx is the control command
execution condition)
【
@GCC / @SCC Control command link
Setting
example
Command
Response
@DEC,201
@DEC,201
Description Deleting the link between COMMAND A and PLANE A.
Remarks
-