![IDK DFS-01HD Command Reference Manual Download Page 43](http://html1.mh-extra.com/html/idk/dfs-01hd/dfs-01hd_command-reference-manual_618373043.webp)
DFS-01UHD/DFS-01HD Command Guide
43
@GHC
System check
Getting
Command @GHC
Response @GHC, temp, rpm, voltage
Parameter
temp : Internal temperature status
0 = No problem detected, 1 = Problem detected
rpm
: Cooling fan status
0 = No problem detected, 1 = Problem detected
voltage : Power-supply status
0 = No problem detected, 1 = Problem detected
Getting
example
Command
Response
@GHC
@GHC,0,0,0
Description Getting the system check result
No problem in internal temperature, cooling fan or power supply status
Remarks
-
@GLM / @SLM
Key function lock
Getting
Command @GLM
Response @GLM, lock
Setting
Command @SLM, lock
Response @SLM, lock
Parameter
lock: Key function lock
0 = Releasing lock [Default], 1 = Locking, 2 = Changing the current setting
Getting
example
Command
Response
@GLM
@GLM,1
Description Getting the key function lock status
Locked
Setting
example
Command
Response
@SLM,1
@SLM,1
Description Enabling the key function lock
Remarks
-
@GIV
Version
Getting
Command @GIV
Response @GIV, id, ver
Parameter
id : Model number
ver : Firmware version
Getting
example
Command
Response
@GIV
@GIV,DFS-01UHD,1.00R0
Description Getting the product information
Model number and firmware version are replied
Remarks
-