DDC-03UHD User
’s Guide
34
*1
ARC and HEC are not supported.
*2
HDR is supported if external EDID is selected while an HDR-supported sink device is connected for EDID setting or if copied EDID of an HDR-supported sink device is selected
for EDID setting.
*3
3D is supported if external EDID is selected while a 3D-supported sink device is connected for EDID setting or if copied EDID of 3D-supported sink device is selected for EDID
setting.
*4
4K format: the following color depths are supported.
・
24 Hz / 25 Hz / 30 Hz: 24 bit, 30 bit, 36 bit (RGB, YCbCr 4:4:4, YCbCr 4:2:2)
・
50 Hz / 59.94 Hz / 60 Hz: 24 bit, 30 bit, 36 bit (YCbCr 4:2:2, YCbCr 4:2:0)
: 24 bit (RGB, YCbCr 4:4:4)
*5
Sampling frequency for when built-in EDID is selected is 32 kHz to 48 kHz.
*6
The distance mentioned above is the maximum extension range acquired under the following environments :
・
1080p@60: IDK
’s AWG24 cable was used and signals of 1080p@60 24 bit / pixel (8 bit / component) was input or output.
・
4K@60:18 Gbps hi-speed transmission cable was used and signals of 4K@60 24 bit / pixel (8 bit / component) was input or output.
The maximum distance depends on connected devices. If IDK
’s cable is not used, video may be interrupted or may not be output even within the mentioned range.
*7
Only supported for GROUP1
’s EDID (No.0 to No.6) and GROUP 2’s EDID (No.0 to No.D)
*8
For digital systems, some problems, such as an HDCP authentication error, can often be recovered by physically disconnecting and reconnecting the digital cables. The
Connection Reset feature will fix these problems automatically without the need to physically plug and unplug the cables. The DDC-03UHD passes through the Connection Reset
function. If other devices are connected between the DDC-3UHD and the sink device, this feature may be invalid.
Power consumption
About 2 Watts
Dimensions
3.46” (W) x 0.9” (H) x 2.75” (D) (88 mm x 23 mm x 70 mm)
(projections are not included)
Weight
0.44 lb. (0.2 kg)
Temperature
Operating: 32 °F to 104 °F (0 °C to +40 °C)
Storage: -4 °F to +176 °F (-20 °C to +80 °C)
Humidity
Operating / Storage humidity: 20% to 90% (Non Condensing)