Idis DC-D Series Installation Manual Download Page 9

Part 1 – Introduction

9

DC-D4513WRX

2

1

4

5

6

8

7

!

9

0

1

IR LED

2

Lens

3

Built-in Microphone

4

Factory Reset Button

5

Bottom Cover

6

Network Port

7

SD Memory Card Slot

8

Cable Access Hole

9

Alarm I/O, Audio I/O

0

Wall/Ceiling Installation Hole

!

Cable Rubber

 

IR LED

A sensor inside the system monitors lighting 
levels and activates the IR LED during low-lighting 
conditions.

 

Lens

Features a fixed focus lens. 

 

Built-in Microphone

Receives audio. 

DC-D4513RX model only

 

Factory Reset Button

Restores the camera's default factory settings. For 
more information, refer to the 

Factory Reset

.

 

Bottom Cover

Allows you to install the camera on a wall or a ceiling.

 

Network Port

Connect a network cable with an RJ-45 connector to 
this port. If using a PoE switch, you can supply power 
to the camera using an ethernet cable. For more 
information on PoE switch use, refer to the switch 
manufacturer's operation manual. You can configure, 
manage, and upgrade this camera and monitor its 
images from a remote computer over the network. 
For more information on network connection setup, 
refer to the 

IDIS Discovery operation manual

.

The following table describes the network cable 
specifications.
<The network cable specifications>

Item

Content

Note

Connector RJ-45
Ethernet

10/100 Base

10/100 Mbps

Cable

UTP Category 5e or 
higher

Maximum 
length

100m

PoE

IEEE 802.3af, Class 2

 

SD Memory Card Slot

Used to insert a microSD memory card into the 
camera. (An SLC (Single Level Cell) or MLC (Multi Level 
Cell) card by SanDisk or Transcend is recommended)

 

Do not remove the SD memory card while the 
system is in operation. Removing the card while 
the system is in operation can cause the system 
to malfunction and/or corrupt data stored on the 
SD memory card.

 

An SD memory card is a consumable product 
with a finite service life. Prolonged use will 
damage the card's memory sectors and result 
in data loss or memory card failure. Test the SD 
memory card regularly and replace it whenever 
necessary.

Summary of Contents for DC-D Series

Page 1: ...Powered by DC D Series Installation Manual DC D4513RX DC D4513WRX...

Page 2: ...h explanation about some functions may not be incorporated The manufacturer is not responsible for any problems resulting from the use thereof The information contained herein is subject to change wit...

Page 3: ...ng storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the equipment due to li...

Page 4: ...from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or th...

Page 5: ...ory Reset 11 Installation 11 Removing the Dome Cover 11 Inserting a SD Memory Card 12 Installation 12 Angle Adjustment 14 Closing the Dome Cover 14 Dimension 15 Part 2 Camera Connection 17 With Direct...

Page 6: ...b browser or remote software Automatic web casting code HTML generation Up to 10 simultaneous remote monitoring connections IP filtering HTTPS SSL IEEE 802 1X and configurable user authority levels fo...

Page 7: ...ncluded External appearances and colors of the accessories may vary depending on the model DC D4513RX DC D4513WRX Guide Pattern Network Camera Quick Guide Screws and Anchors each 2 ea Protect Connecto...

Page 8: ...Part 1 Introduction 8 Overview Product color and design may vary depending on the model Dome Cover DC D4513RX DC D4513WRX Body DC D4513RX 2 1 3 4 5 6 8 7 9 0...

Page 9: ...s operation manual You can configure manage and upgrade this camera and monitor its images from a remote computer over the network For more information on network connection setup refer to the IDIS D...

Page 10: ...al inductive load e g relay a diode must be connected in parallel with the load for protection Otherwise the product could be damaged I In Connect an alarm in device to this port Mechanism Choose betw...

Page 11: ...restored to their factory defaults after the reboot It s also possible to do a factory reset by pressing and releasing the reset button while the camera is turned on or using the IDIS Discovery progra...

Page 12: ...ages from the slot and then pull it out Installation Check the wall or ceiling to see if it needs to be reinforced The camera may fall off if the wall or ceiling is not strong enough to support its we...

Page 13: ...gh the cable rubber using the protective connector provided Cable rubber Cable Protect connector 2 Assemble the cable rubber to the bottom cover 3 Use the screws anchors provided with the camera to se...

Page 14: ...on 2 Vertical Rotation Lens Rotation Used to adjust the lens rotation angle Turn the rotator in clockwise or counterclockwise direction Vertical Rotation Used to adjust the lens vertical angle Turn th...

Page 15: ...Part 1 Introduction 15 DC D4513WRX Fasten the screws for the dome cover clockwise using the Allen wrench provided with the camera Remove the protective film outside Dimension DC D4513RX 110mm 88mm...

Page 16: ...Part 1 Introduction 16 DC D4513WRX 120mm 92 9mm...

Page 17: ...rk Alarm Out Alarm In Audio In Audio Out DirectIP NVR makes it easy to use cameras without extra network configurations Each camera can be controlled via the DirectIP NVR setup menu without any PC For...

Page 18: ...ite Compact microSD Memory Card Audio Out Audio In Alarm In Alarm Out Control the camera over the network from software installed on a computer Ideal for using the camera over the network from a remot...

Page 19: ...picking up an overly bright light source adjust the camera s position angle accordingly Video color appears incorrect Check the white balance settings If using the Auto option it may take some time f...

Page 20: ...Speed Auto Manual 1 30 1 8 000 Anti Flicker Slow Shutter 1 1 5 1 7 5 1 15 Day Night IR cut filter with auto switch IR Distance LEDs DC D4513RX 2 8mm 30m 4ea DC D4513RX 4 0mm 20m 2ea DC D4513WRX 30m 4e...

Page 21: ...In 1 TTL NC NO Programmable 4 3V NC or 0 3V NO threshold 5V DC Alarm Out 1 TTL open collector Max load 30mA Max voltage 5VDC General Operating Temperature DC D4513RX 10 C 50 C 14 F 122 F DC D4513WRX 3...

Page 22: ...IDIS Co Ltd For more information please visit at www idisglobal com...