Part 3 - Configuration
22
RAID Rebuilding
When one of the hard drives fails, replace the hard drive with new one and RAID rebuilding will begin automatically.
•
RAID rebuilding is not supported for the SATA Port Multiplier and RAID 0 modes.
•
If you replace two hard drives at once, RAID rebuilding will proceeds sequentially one by one.
1
When one of the installed hard drives fails, beep will sound and the LED corresponding failed HDD on the front
panel will blink sequentially in green and red. Press and hold the Setup button on the front panel with the
straightened paperclip for 3 seconds to turn off the audio warning.
2
Replace the failed hard drive with a new one and RAID rebuilding will begin automatically.
Specifications
Host connection interface
External eSATA port (NVR connection)
Max. transfer rate (SATA II): 3.0Gbps, Cable length: Max. 2.0m
Disk connection interface
SATA hard drives (Max. 4), 1.5Gbps or 3.0Gbps (Auto detection)
Dimensions (W x H x D)
18.90" x 1.73" x 13.62" (480mm x 44mm x 346mm)
Unit weight
14.1 lbs. (6.4kg)
Shipping weight
17.9 lbs. (8.14kg)
Operating temperature
41°F to 104°F (5°C to 40°C)
Operating humidity
0% to 90%
Power supply
100V ~ 240VAC, 0.6-0.3A, 50/60Hz
Power consumption
Max. 40W
Certifications
FCC, CE, CB, UL*
*
CAUTION
: There is risk of explosion if the battery is replaced with an incorrect type. Dispose used batteries according
to the instructions. This equipment is intended for indoor use only and all the communication wiring must be limited
to indoors.
Specifications are subject to change without notice.
V1.0