background image

 

28 

Step12. Run a Serial Port Tool, e.g. HyperTerminal on your computer. This step guarantees the terminal 
to complete establishing Bluetooth communication. And then scan a barcode to confirm the success of 
data transmission. 

 

 

5-3-4 Configure Bluetooth SPP Master Profile Communication 

Note: Make sure the Bluetooth module of the terminal is powered on (blue LED is on) and the selected 
profile is System Setting

Bluetooth

BT SPP Master. 

Step1. Press Left Soft Key to the window below. If the terminal has no connection record, it will show the 
indication” There is no connection record.” 

 

Step2. Press Left Soft Key to the window below for searching. 

 

Step3. Wait for about 20 seconds and then the devices list will be shown. 

 

Step4. Use Navigation Key to move the cursor and press Scan/Select Key to connect to the Bluetooth 
USB adapter. 

 

 

Summary of Contents for MS3390

Page 1: ......

Page 2: ...change without notice 4 The manufacturer assumes no responsibility for any loss or claims by third parties which may arise from the use of this manual 5 Do not throw or drop the terminal or otherwise...

Page 3: ...ii...

Page 4: ...taching the neck wrist strap 10 2 4 Replacing the Lithium ion battery 10 3 Getting started 11 3 1 Power on off terminal 11 3 2 Charge battery 11 3 3 Enter Exit sleep mode 11 3 4 Power on off Bluetooth...

Page 5: ...e the Profile of BA2110 30 5 4 System Setting General 32 5 4 1 Language 32 5 4 2 Volume of Beeper 32 5 4 3 Vibrator 32 5 4 4 Backlight Timeout 32 5 4 5 Sleeping Timeout 32 5 4 6 Default Setting 32 5 4...

Page 6: ...7 22 Telepen 68 7 23 GS1 DataBar GS1 DataBar Truncated 70 7 24 GS1 DataBar Limited 71 7 25 GS1 DataBar Expanded 72 7 26 G1 G6 FN1 substitution string setting 73 7 27 G1 G4 string position Code ID posi...

Page 7: ...vi...

Page 8: ...idth Depth 11 0 4 3 2 7 cm Weight 89g Color Black White Customization Case material ABS Indicator Beeper LED Vibrator Display LCD monochrome display 128 64 with LED backlight Input Voltage 4 75V 5 25V...

Page 9: ...mware upgrade Online via USB interface Safety Laser safety EN60825 1 class 1 EMC EN 55022 EN 55024 Electrical safety EN 60950 1 ESD 8KV air discharge 4KV direct discharge Drop resistance Multiple 1 5m...

Page 10: ...rleaved 2 of 5 6 I Im Industrial 2 of 5 4 H Im Matrix 2 of 5 6 X Im Codabar 4 N Fm Code 128 1 K Cm Code 93 1 L Gm Code 11 4 V MSI Plessey 4 O Mm UK Plessey 1 U Mm UCC EAN 128 1 K Cm China Post 11 2 T...

Page 11: ...ide narrow element ratio Barcode content Contrast 4 0 mil Code 39 2 5 1 ABCDEFGH 80 5 0 mil Code 39 2 5 1 ABCDEFGH 80 7 5 mil Code 39 2 5 1 ABCDEF 80 10 mil Code 39 2 5 1 ABCDE 90 13 mil 100 UPC 12345...

Page 12: ...5 1 4 Dimensions Figure 1 2 Dimensions of the terminal Figure 1 3 Dimensions of the Bluetooth USB adapter...

Page 13: ...ed LED Charging indicator 2 LCD 3 Left soft key 4 Right soft key 5 Up navigation key 6 Left navigation key 7 Right navigation key 8 Down navigation key 9 Scan Select key 10 Return key 11 Bluetooth on...

Page 14: ...7 1 6 Parts of the Bluetooth USB adapter BA2110 Figure 1 5 Parts of the Bluetooth USB adapter BA2110 19 Reset Firmware upgrade key 20 Green LED Power Data transmission...

Page 15: ...ressed to scan barcodes when the terminal is not in a menu status the select key is pressed to select items when a menu is activated 5 Up navigation key is pressed to move cursor upward downward 8 Dow...

Page 16: ...ountered during the installation process unplug the USB cable from the computer and repeat step 1 2 Figure 2 1 Diagram of connecting the terminal to PC 2 2 Installing a USB virtual COM wired terminal...

Page 17: ...t the corner 3 Screw in the 3 screws to tighten the terminal and the battery cover Figure 2 2 Diagram of attaching the neck wrist strap 2 4 Replacing the Lithium ion battery 1 Refer to Figure 2 2 remo...

Page 18: ...harged 3 In scanning status the icon is seen at the top of the screen display when the terminal is connected to a PC with the USB cable Method I Method II Figure 3 1 Diagram of charging battery 3 3 En...

Page 19: ...display icons Icon Description Bluetooth network is working Bluetooth network is disconnected Bluetooth module is on Bluetooth module is off Support for switching among the input of barcode scanning a...

Page 20: ...uantity Database Query 1 Disable 2 Enable Avoid Duplication 1 Disable 2 Enable Transfer Confirm 1 Disable 2 Enable Set Separator Input Data Manually Send Add Date Sum Total Barcode Statistics 1 Disabl...

Page 21: ...min 2 5min 3 10min 4 Off Bluetooth BT HID Keyboard BT SPP Slave BT SPP Master 1 USA 2 French 3 USB HID keyboard 1 USA 2 French 3 System Setting 1 Time 2 Date BA2110 1 Volume 2 Key Tone 1 Low 2 Middle...

Page 22: ...barcode and press the Scan Key Note When the terminal is scanning ensure the scan line crosses every bar and space of the symbol RIGHT WRONG Step 3 The terminal port emits a laser to scan the barcode...

Page 23: ...ost given that the quantity is 5 The quantity decides how many identify barcodes a host receives upon a single successful read Separator Setting When user selects Output Quantity mode the barcode and...

Page 24: ...most 10 characters Example1 A barcode 123456789 is read in 12 00 00 at 25 05 2012 When user selects Output Quantity mode 123456789 5 will be received by the host given that the quantity is 5 123456789...

Page 25: ...er can clear the previous barcode record by entering the same barcode avoidance setting menu page and pressing the left soft key clear 5 1 9 Barcode Statistics The terminal will automatically count an...

Page 26: ...mptying deleting some files A target file is protected by system and prevented from being deleting In this case the file that is wanted to be deleted should be deselected and then deleted 5 1 12 Trans...

Page 27: ...y time is set to 10 seconds For more detail please refers to 5 3 6 Configure the profile of BA2110 5 2 2 USB HID Keyboard When the terminal is USB connected to a PC it will be identified as a USB HID...

Page 28: ...plete 2 List Files This menu can be selected to list all files in the root directory The file selected to be the target file is labeled The operations described below are imposed to the cursor on file...

Page 29: ...to a host via Bluetooth USB Three options are listed below Send batch data Data transmission is triggered by this menu command Before undertaking this operation make sure a communication link Bluetoot...

Page 30: ...e and is the Slave SPP master The terminal connects to the PC host via Bluetooth and behaves like there is a serial connection The terminal initiates the connection to the remote device and is the Mas...

Page 31: ...k Next Step5 It takes a few seconds for the Wizard to search devices The terminal will appear with its serial number as the device name If the target terminal is seen on the list click and select the...

Page 32: ...the connection request Press Left Soft Key to accept Step8 Enter a passkey which is exactly the same as that entered from the PC Use Navigation Key to move the cursor Scan Select Key to select number...

Page 33: ...26 Step10 Click Finish Step11 Now the target terminal will be listed as shown below Step12 Run the desired application such as a Notepad and scan barcodes to check data transmission...

Page 34: ...the Bluetooth module of the terminal is powered on blue LED is on and the selected profile is System Setting Bluetooth BT SPP Slave Step1 9 The same as Configure Bluetooth HID keyboard step 1 9 Step1...

Page 35: ...module of the terminal is powered on blue LED is on and the selected profile is System Setting Bluetooth BT SPP Master Step1 Press Left Soft Key to the window below If the terminal has no connection...

Page 36: ...communication is unacceptable 2 Make sure the Bluetooth module of the terminal is powered on blue LED is on 3 By default the profile of the BA2110 is USB HID keyboard An alternative option is USB vir...

Page 37: ...eled Step7 If you want to disconnect the BA2110 connected successfully before you can press Scan Select Key to disconnect it 5 3 6 Configure the Profile of BA2110 Note Before the configuration make su...

Page 38: ...habetic key Numeric key the terminal will output code result as pressing numeric keypad 0 1 2 3 4 5 6 7 8 9 only Alt keypad the terminal will output code result as pressing Alt numeric key on keypad N...

Page 39: ...f no operation exceeds Backlight timeout 5 4 5 Sleeping Timeout The terminal will enter sleep mode if time of no operation exceeds Sleeping timeout User can set the terminal to sleep mode by press Pow...

Page 40: ...r customized application software and enable the boot settings the system is run directly to the user s application when switched on When user keep pressing the right soft key during system booting st...

Page 41: ...Key to erase data to release used memory Caution 1 Erasing operation will delete all data in the memory 2 Erasing operation is not undoable 5 5 2 Bluetooth Module User can view the name and address o...

Page 42: ...ng the system state is only allowed after the correct password is provided Pressing the return key could lead to the user customized application software state For more information on system password...

Page 43: ...llation key by MS3 SDK Click Download Download Installation Key Notice Please be sure the installation key is properly downloaded to the terminal before you start to download encrypted file ENP file t...

Page 44: ...setting part Notes 1 Only one parameter can be setup at each time 2 During the process of programming LED is lighting to indicate the programming correctness LED will go off if any incorrect programm...

Page 45: ...arcode will not be readable In particular the same value can be set for both minimum and maximum reading length to force the fixed length barcode decoded Notes 1 Please set the max min length for indi...

Page 46: ...o 00 09 00 Global max code length 04 99 04 99 99 Global min code length 01 99 01 99 04 Global G1 G4 string selection 00 44 00 44 00 Element amendment Disable Enable 00 01 Printable character only Disa...

Page 47: ...The Supplement digits barcode is the supplemental 2 or 5 characters Format Leading zero Data digits 11 digits Check digit Supplement digits 2 or 5 Truncation Expansion Truncate leading zeros The leadi...

Page 48: ...eck digit trans Disable Enable 00 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 2 digits 5 digits 2 or 5 digits 00 01 02 03 Truncation Expansi...

Page 49: ...nsion Truncate leading zeros The leading 0 digits of UPC E data characters can be truncated when the feature is enabled Example Barcode 00123457 Output 123457 Expand to EAN 13 It extends to 13 digits...

Page 50: ...trans Disable Enable 00 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 2 digits 5 digits 2 or 5 digits 00 01 02 03 Truncation Expansion None Tr...

Page 51: ...6 digits Check digit Supplement digits 2 or 5 Truncation Expansion Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is enabled Example Barcode 10012341 Output 0100120000031 Exp...

Page 52: ...00 01 Check digit trans Disable Enable 00 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 2 digits 5 digits 2 or 5 digits 00 01 02 03 Truncation...

Page 53: ...Insertion group selection of 7 3 UPC A Supplement digits Format Data digits 12 digits Check digit Supplement digits 2 or 5 ISBN ISSN conversion The ISBN International Standard Book Number and ISSN In...

Page 54: ...e Enable 00 01 Check digit transmission Disable Enable 00 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 2 digits 5 digits 2 or 5 digits 00 01...

Page 55: ...ction of 7 3 UPC A Supplement digits Format Data digits 7 digits Check digit Supplement Digits 2 or 5 Truncation Expansion Refer to Truncation Expansion of 7 3 UPC A SETUP Option bar code Option Alpha...

Page 56: ...code decoded Code ID setting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A Start End transmission The start and end characters of Code...

Page 57: ...99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert group selection 00 66 00 66 00 Format Standard Full ASCII 00 01 Start End transmission Disable Enable 00 01 as data character Disable Enable...

Page 58: ...y setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 7 8 Code 39 Code ID setting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer t...

Page 59: ...ing Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Max code length 0...

Page 60: ...Refer to Max Min code length of 7 8 Code 39 Code ID setting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A SETUP Option bar code Option...

Page 61: ...code length Refer to Max Min code length of 7 8 Code 39 Code ID setting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A Start End type C...

Page 62: ...mission Disable Enable 00 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 00 Code ID setting 00 FF16 ASCII 00 FF16 N Insert group selection 00 66 00 66 00 Start End type ABCD ABCD abcd a...

Page 63: ...group selection Refer to Insertion group selection of 7 3 UPC A Truncate leading zeros The leading 0 digits of Code 128 barcode characters can be truncated when the feature is enabled SETUP Option ba...

Page 64: ...ing of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A Truncate leading zeros Refer to Truncate leading zeros of 7 12 Code 128 SETUP Option bar code Option Alpha en...

Page 65: ...check digit verification is optional Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 7 8 Code 39 Code ID setting Refer to...

Page 66: ...le Enable 00 01 Check digit verification Disable Enable 00 01 Check digit transmission Disable Reserved 00 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCI...

Page 67: ...efer to Max Min code length of 7 8 Code 39 Code ID setting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A SETUP Option bar code Option...

Page 68: ...d Max Min code length Refer to Max Min code length of 7 8 Code 39 Code ID setting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A SETUP...

Page 69: ...check digit 2 will be transmitted upon your selected check digit verification method Max Min code length Refer to Max Min code length of 7 8 Code 39 Code ID setting Refer to Code ID setting of 7 3 UP...

Page 70: ...transmitted Max Min code length Refer to Max Min code length of 7 8 Code 39 Code ID setting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 U...

Page 71: ...tting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Reserved Reserv...

Page 72: ...efer to Max Min code length of 7 8 Code 39 Check digit verification The check digit is made as the sum module 10 of the numerical values of all data digits Leading character 5 6 7 8 9 converted to A B...

Page 73: ...Enable Only 5 converted to A Only 6 converted to B Only 7 converted to C Only 8 converted to D Only 9 converted to E 00 01 02 03 04 05 06 Leading character assignment Disable Assigned to 0 Assigned to...

Page 74: ...ting By scanning the barcode above the decoding direction of the terminal s laser light is from left to right By scanning the up side down barcode above the decoding direction of the terminal s laser...

Page 75: ...length Refer to Max Min code length of 7 8 Code 39 Code ID setting Refer to Code ID setting of 7 3 UPC A Insertion group selection Refer to Insertion group selection of 7 3 UPC A Encode character set...

Page 76: ...git verification Disable Enable 00 01 Check digit transmission Disable Enable 00 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 00 FF16 P Insertion group sele...

Page 77: ...ion of 7 3 UPC A Conversion UCC EAN 128 Refer to Code ID transmission of 7 28 String transmission Cm will be identified as AIM ID UPC A or EAN 13 Barcode beginning with a single zero as the first digi...

Page 78: ...n Refer to Insertion group selection of 7 3 UPC A Conversion Refer to Conversion of 7 23 GS1 DataBar GS1 DataBar Truncated SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Code ID se...

Page 79: ...of 7 3 UPC A Conversion UCC EAN 128 Refer to Code ID transmission of 7 28 String transmission Cm will be identified as AIM ID SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Max co...

Page 80: ...or all symbologies Steps 1 Scan SETUP and Prefix string setting barcode 2 Use the ASCII table to find the value of 24 3 Scan 2 and 4 from the barcode on the foldout back page 4 Scan END barcode Scanni...

Page 81: ...5 6 Steps scan the following data in order Testing barcode Truncate ending G6 string setting By setting a defined ending character or string can be truncated Also a single character can be un defined...

Page 82: ...F16 00 Insert G2 string setting 0 22 characters None 00 FF16 00 Insert G3 string setting 0 22 characters None 00 FF16 00 Insert G4 string setting 0 22 characters None 00 FF16 00 FN1 substitution strin...

Page 83: ...ode Option Alpha entry Repeat of a G6 character setting Once Defined times Un defined times All 01 01 22 FF Single character C1 replacement 0000 0000 0000 FFFF 16 Single character C2 replacement 0000...

Page 84: ...of the insertion position is greater than the length of the symbol the insertion of string is not effective Code ID position It is allowed to select different positions of code ID placement SETUP Opt...

Page 85: ...be transmitted in the format of either Proprietary ID or AIM ID Refer to 1 2 Default setting for each barcode Code length transmission The length of code data string can be transmitted before the cod...

Page 86: ...on Disable Enable 00 01 Code ID transmission Disable Proprietary ID AIM ID 00 01 02 Code length transmission Disable Enable 00 01 Case conversion Disable Upper data only Lower data only Upper whole st...

Page 87: ...de is different 2 If using CODESOFT software firstly read the information through Help Index Code128 Special input syntax Also refer to ASCII table For example if we wish to make F1 barcode select cod...

Page 88: ...8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for keyboard wedge only...

Page 89: ...Test Chart UPC A UPC E UPC E1 EAN 13 ISBN ISSN EAN 8 Code 39 Code 32 A908765439 Trioptic Code 39 Default setting Disable Interleaved 2 of 5 Industrial 2 of 5 Default setting Disable Matrix 2 of 5 Cod...

Page 90: ...tinued Code 128 UCC EAN 128 ISBT 128 Code 93 Code 11 Default setting Disable MSI Plessey Default setting Disable UK Plessey China Post Telepen GS1 DataBar GS1 DataBar Truncated GS1 DataBar Limited GS1...

Page 91: ...84 11 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...

Page 92: ...on 2 2 Select the appropriate Bluetooth profile by setting System Setting Bluetooth BT HID Keyboard 3 Guide for iPhone to establish Bluetooth connection with MS3390 3 1 Make sure the Bluetooth module...

Page 93: ...uch inconvenience the MS3390 terminal provides the support of simultaneous use of scanning and on screen keystrokes This feature is enabled by default and is operated as follows 1 Connect MS3390 to th...

Reviews: