Summary of Contents for Aspect 100-4 Q-CARD

Page 1: ...Made in the USA with global materials Aspect 100 4 Mobile Image Table Operator Manual...

Page 2: ...agencies regarding specific requirements and regulations applicable to the use of this equipment Image Diagnostics Inc certifies only the equipment After sale operating practices and safety are the re...

Page 3: ...3 TABLE MOTION CONTROLS 15 9 STANDARD ACCESSORIES 16 Please reference website for most up to date list of available accessories for purchase No IDI Accessories nor components of accessories listed be...

Page 4: ...gnostics com 4 11 GENERAL CLEANING 22 12 MAINTENANCE SERVICE REPAIR 23 12 1 RECOMMENDED PERIODIC PERFORMANCE CHECKS 23 12 2 SERVICE REPAIR STATEMENT 23 13 TROUBLESHOOTING 24 14 DISPOSAL OF COMPONENTS...

Page 5: ...esult in death personal injury or damage to the equipment Emergency Stop Pushbutton Electric Shock hazard Information or instructions shown near this symbol must be adhered to in order to prevent a po...

Page 6: ...d Representative Model of Table Serial Number of Table Indication of European Conformity for sale in the European Economic Area EEA Item complying to Type B applied part per IEC 60601 1 Date of manufa...

Page 7: ...disrupted 3 SAFETY INSTRUCTIONS All persons using this equipment must fully understand its operation instructions emergency procedures capabilities including total range of motion and be aware of all...

Page 8: ...not been tested for use with high frequency surgical equipment cardiac defibrillators or cardiac defibrillator monitors Use with such equipment may cause patient burns explosion hazards or electrical...

Page 9: ...the safety of patient and operator CAUTION During operation of the table if any unusual sounds and or erratic movement is observed immediately discontinue use of the table CAUTION Do not use table fo...

Page 10: ...no closer than 30 cm 12 inches to any part of the Aspect 100 4 including cables connected to the table Otherwise degradation of the performance of this equipment could result NOTE The emissions charac...

Page 11: ...with the controls before using them External electrical power connection and disconnection is through the AC power cord and outlet The table will operate on 110 V 230 V or on internal battery backup...

Page 12: ...assive magnetic brake it remains engaged energized in the event of a complete loss of electrical power Power is necessary to release the brakes As the braking system utilizes permanent magnetic brakes...

Page 13: ...break and then transfer the patient onto the Table 7 4 Preparation for Performing CPR Return table to level position retract tabletop to minimize overhang and lower table position to a comfortable hei...

Page 14: ...ully engaged The Rear Casters will be totally locked and will not roll in any direction Always lock all casters in this way before loading the patient The table is in the UNLOCK setting when the Caste...

Page 15: ...ngaged 8 3 TABLE MOTION CONTROLS Aspect 100 4 tables are equipped with tabletop motion control boxes that allow users to move the tabletop in many different directions Continually pressing down on the...

Page 16: ...Accessory Rail Then the Unit can be slid along the rail or removed 9 STANDARD ACCESSORIES Please reference website for most up to date list of available accessories for purchase No IDI Accessories nor...

Page 17: ...bletop hangs down between the rails and the tabletop and wrapped over the outside of the rails to meet over the top of the table If the strap is to be used along the rest of the tabletop slide the str...

Page 18: ...ble 6 length European version with 10mm x 25mm metric rail is available 10 2 Vascular Access Arm Board VAB One piece extra wide carbon fiber arm board for vascular access procedures Mounts to table by...

Page 19: ...opean version for 10mm x 25mm metric rail size is available 10 4 Arm Board Shoulder Mount Carbon fiber base Mounts to table by sliding under Patient Mattress Pad Includes padded arm board and restrain...

Page 20: ...pivoting the extension up or down to angle the patient s head To remove the Articulating Headrest Extension from the Tabletop depress the release levers located on the underside of the extension and p...

Page 21: ...l and the tabletop by clamp 10 9 Anesthesia Screen Holder May require a pair of side rail clamps Flexible Hoop If this is to be used in an area of the tabletop that has no side rails then a pair of Cl...

Page 22: ...cord Handset Control and Foot Control cords must be plugged in at the table base to protect the inside of the connectors from debris e Remove all pads and accessories f Wipe off any excess fluids wit...

Page 23: ...erviceable Replacement must be performed only by a qualified service technician Weekly Check battery operation by disconnecting the AC power and running the tabletop up and down Run the table top thro...

Page 24: ...of time 2 Contamination on brake surfaces or improper cleaning or maintenance performed 1 Release brakes using Tabletop Motion Control Panhandle and move tabletop in all directions Working tabletop mo...

Page 25: ...Board Housing Cable Electronic Plastic Copper Table Base Frame Casters Covers Metal Steel Plastic and Steel Stainless Steel Electronic waste and batteries Electronic components and devices must be dis...

Page 26: ...in Patient capacity 272 kg 600 lbs without tabletop extensions Emergency Stop Pushbutton Multi caster 2 Position Multi lock system Total Lock Steer Backup battery power 16 SPECIFICATIONS Mode of Oper...

Page 27: ...equirements of FDA CFR Title 21 Chapter 1 Subchapter J Guidance and Manufacturer s Declaration Emissions All Equipment and Systems Table 1 The Aspect 100 4 is intended for use in the electromagnetic e...

Page 28: ...1kV 2 kV Line to Ground Main power quality should be that of a typical commercial or hospital environment Voltage Dips Dropout EN IEC 61000 4 11 0 UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 0 UT...

Page 29: ...and between 0 15MHz and 80MHz 80 AM at 1kHz see table 5 of IEC 60601 1 2 3V m 80MHz to 2 7GHz 80 AM at 1kHz AC Mains 3V 0 15MHz 80MHz 6V in ISM band between 0 15MHz and 80MHz 80 AM at 1KHz see table 5...

Page 30: ...tput power of the Communications Equipment Table 4 Max Output Power Watts Separation m 150kHz to 80MHz D 3 5 3 Sqrt P Separation m 80 to 800MHz D 3 5 3 Sqrt P Separation m 800MHz to 2 5GHz D 7 3 Sqrt...

Reviews: