background image

VIKING PUMP, INC.

 

 A Unit of IDEX Corporation

 

 

Cedar Falls, IA 50613 USA

VIKING PUMP, INC.

 

 A Unit of IDEX Corporation

 

 

Cedar Falls, IA 50613 USA

TECHNICAL SERVICE MANUAL  

figure 1

Model KKe4076M

(Shown with relief valve on pump casing  

and flange mounted bracket - M Drive)

figure 2

Model LQe4176

(Shown with relief valve on pump casing  

and foot mounting)

SECTION  TSM 710
PAGE

 1 Of 8

ISSUE

 D

CONTeNTS

iNTrODuCTiON

The illustrations used in this manual are for identification 

purposes only and cannot be used for ordering parts. Obtain a 

parts list from the factory or a Viking® representative. Always 

give complete name of part, part number and material with 

model number and serial number of pump when ordering 

repair parts. The pump model number and serial number are 

on the nameplate.
This manual deals only with Viking 4076/4176 pumps. 

 

Specifications and recommendations are listed in Catalog 

Section 710.

Introduction . . . . . . . . . . . . . . . . . . . . . . . 

1

Safety Information.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  

2

Special Information . . . . . . . . . . . . . . . . . . . 

3

 

Rotation.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  

3

  Pressure Relief Valves . . . . . . . . . . . . . . . . 

3

Maintenance  . . . . . . . . . . . . . . . . . . . . . . 

3

 Bushings . . . . . . . . . . . . . . . . . . . . . . . 

3

  Cleaning the Pump .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  

3

 Storage .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  

3

  Suggested Repair Tools . . . . . . . . . . . . . . . 

3

Disassembly  . . . . . . . . . . . . . . . . . . . . . . 

4

Assembly . . . . . . . . . . . . . . . . . . . . . . . . 

6

Mechanical Seal  . . . . . . . . . . . . . . . . . . . . 

6

Thrust Bearing Adjustment . . . . . . . . . . . . . . . 

7

Installation of Carbon Graphite Bushings .   .   .   .   .   .   .   .  

7

Installation of Foot  . . . . . . . . . . . . . . . . . . . 

7

Pressure Relief Valve Instructions . . . . . . . . . . . 

7

 

Relief Valve Pressure Adjustment . . . . . . . . . . 

8

uNMOuNTeD PuMP

uNiTS

Flange

Mounted

Foot

Mounted

Units are designated by the un-

mounted pump model numbers 

followed by a letter indicating 

drive style.

M

 = Horizontal

D

 = Direct Drive

KE4076

LQE4176

KKE4076

LQE4076

TabLe 1

Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com

iNDuSTriaL heavy DuTy MOTOr SPeeD PuMPS

SerieS 4076 aND 4176

 

SiZeS Ke, KKe aND LQe

PRODUCT 

OBSOLETED 

3Q16

Summary of Contents for Viking Pump 4076 Series

Page 1: ...the nameplate This manual deals only with Viking 4076 4176 pumps Specifications and recommendations are listed in Catalog Section 710 Introduction 1 Safety Information 2 Special Information 3 Rotatio...

Page 2: ...base plate refer to the Viking Pump product catalog DO NOT attempt to dismantle a pressure relief valve that has not had the spring pressure relieved or is mounted on a pump that is operating AVOID co...

Page 3: ...ed on both sides of the pump See also ROTATION Relief valve adjusting screw cap must always point towards the suction side of the pump Pressure relief valves are intended for use as protection for the...

Page 4: ...rt a length of hardwood or brass through the port opening between the rotor teeth to keep the shaft from turning Straighten out the lock washer tab and with a spanner wrench remove the locknut and loc...

Page 5: ...Lube Pin 11 Setscrew M8 1 5 x 14 mm 2 Req d 31 Head and Lube Idler Pin Assembly 12 Bearing Housing 32 Pipe Plug Hex Head 1 4 BSP 13 Capscrews For Seal Plate 2 Req d 33 O Ring For Jacketed Head Plate...

Page 6: ...cap See the appropriate figure for lip orientation Thread the end cap into the bearing housing along with outer bearing spacer collar and tighten against the bearing LQE PUMPS ONLY Tapered roller bea...

Page 7: ...ee ASSEMBLY on page 5 reference notes under item 4 and 5 4 High viscosity liquids require additional end clearances The amount of extra end clearance depends on the viscosity of the liquid pumped For...

Page 8: ...IEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ALL WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT ALL OF WHICH OTHER WARRANTIES ARE EX...