![Idex MICROPUMP DEELE Installation, Operation And Warranty Information Download Page 8](http://html1.mh-extra.com/html/idex/micropump-deele/micropump-deele_installation-operation-and-warranty-information_617820008.webp)
8
DOC No: 8540 REV D
Before installing the product ensure all transit packaging has been removed.
Remove the blanks from any inlet and outlet ports. If the pump is to be stored prior to
installation, re-pack the pump in its original packing, refit the blanks to the ports and store
in a dry, covered environment.
Protect the pump head from damage during unpacking and installation. Impacts to the
magnet cup can cause internal damage or result in rub between the magnet cup and
driven magnet upon assembly with the motor.
Inspect the magnet cup before assembly with the motor. Replace or
repair if there are signs of damage.
If the pump head housing assembly and EagleDrive motor are supplied separately they
will need to be assembled prior to the installation.
Insert the drive housing seal (1) into the groove in the face of the housing (3). Align the
pump assembly flange (2) so that it fits into the matching recesses and rotate clockwise
to engage the housing. Secure using the two screws (4) supplied with the EagleDrive.
Torque screws to 0.8 N-m (7 in-lbs).
Loose bolts may result in pump/motor misalignment. Tighten bolts
appropriately. Pump/motor misalignment may result in weakening the
sealing of the enclosure.
Assembly
Unpacking and Storage
Space Requirements
Refer to the Technical Specification for overall dimensions and weights of the EagleDrive
and some of the most common pump/motor combinations.
3
1
2
4