Multilinking is a way to connect multiple Knight-Trak II dispensers in a laundry. Once connected, you can 
"talk" to all dispensers from a single connection. 

(1) Before connecting the multilinking cable, use the LFP to give each dispenser its own ID number. If 

dispensers on the multilink have the same ID number, they will not work correctly. THIS MUST BE 
DONE BEFORE YOU CAN "LOG-ON" WITH REPORTER PC SOFTWARE OVER THE 
NETWORK. 

(2) Using shielded cable, connect the multilink barriers on each POB in series. Be careful to keep the 

polarity the same on each dispenser. 

(3) A booster transformer must be used if multilinked dispensers are connected to a PC running with 

Reporter software. See Reporter network diagram included in this manual. 

 


3&1(7:25.&$%/(,167$//$7,21

Connecting the Knight-Trak II dispenser network to an on-site PC requires plugging-in the network cable 
to the jack on the POB (Pump Output Board) and connecting other end to a wall-mount booster 
transformer and RM-6000. Please see diagram included in this manual for details. For laptop computers, 
connect the RM-6000 to the female jack on the LFP. 

remote location. See The Reporter Dispenser Network diagram (included in this manual) for more 
information on connecting modems to the network. Please refer to the RM-6000 or WinReporter 
instruction manual for actual setup of the remote modem. A dedicated phone line must be installed 
and connected to the on-site modem. 

NOTE: For installations that require telephone modem 

and 

on-site PC access, contact the sales office  

 

5(3257(53&02'(0,167$//$7,21

Reporter Software features the ability to access dispensers from a remote location via telephone 
modems. A Hayes Acura 336 modem can be used along with a dedicated RM-6000 Reporter Module set 
in modem mode. Contact Knight Technical Services 1-800-241-7789 or 1-800-854-3764 for assistance. 
An RM-6000 Reporter Modem Cable (P/N 0300952) is required to access dispensers from a  

for details on special "Y" network cable. Separate RM-6000’s are required for the PC and modem (see 
diagram).

Summary of Contents for Knight 7667503

Page 1: ...Page 1 of 16 0901039 Rev C 05 01 Knight Trak II Instruction Manual...

Page 2: ...OB Wiring 8 Drawing LFP Wiring 9 Drawing Control Connections for Multilinking 10 The Signal Input Board SIB 11 Drawing SIB Connection 12 The Management Input Board LMIB 13 Network wiring Diagram 15 CA...

Page 3: ...Page 3 of 16 0901039 Rev C 05 01...

Page 4: ...als to low voltage data signals 6 67 0 237 216 1 A Laundry Management Input Board LMIB which receives hot and cold water signals and other information relating to wash cycle tracking 2 A Low Level Ala...

Page 5: ...connect signal wires from the signal source to the SIB Connect the SIB to the LFP Connecting the SIB to the LFP requires a three conductor shielded cable available from Knight Equipment Color coded c...

Page 6: ...Board and connecting other end to a wall mount booster transformer and RM 6000 Please see diagram included in this manual for details For laptop computers connect the RM 6000 to the female jack on the...

Page 7: ...the instructions provided with the system For flush mode to work correctly the flush terminals on the POB must be connected together with a jumper or to a flow sensor If this is not done a flush error...

Page 8: ...0901039 Rev C 05 01 Page 8 of 16...

Page 9: ...Page 9 of 16 0901039 Rev C 05 01...

Page 10: ...0901039 Rev C 05 01 Page 10 of 16...

Page 11: ...isions for split common connection some washmachine s have provisions for separate wash and rinse commons See the next page 5 Connect the color coded interface wire Knight part number 0300058 to the S...

Page 12: ...0901039 Rev C 05 01 Page 12 of 16...

Page 13: ...is signal is used to count the number of drains in a given wash cycle A drain solenoid or a drain track on a card reading machine are typical sources for the drain signal COLD WATER This signal is use...

Page 14: ...0901039 Rev C 05 01 Page 14 of 16...

Page 15: ...0300058 X ONLY 3 CONDUCTOR NETWORK CABLE KNIGHT P N 0300058 ONLY BLACK TERMINAL BROWN TERMINAL MALE W O L F W O L F W O L F W O L F W O L F FLO W W O L F F LO W FLO W FLOW FLO W F LO W W O L F FLO W...

Page 16: ...s such as O rings diaphragms squeeze tubing and gaskets are considered expendable and are not covered under warranty Warranty does not cover liability resulting from performance of this equipment nor...

Reviews: