74
C.
Install two (2) 1/4–20 X 1-1/2-in long machine screws (each with one lock and
one flat washer). NOTE: Do NOT over tighten screws.
D.
Connect electrical connector according to tags.
4.7.2
Flowmeter (Optional – Used with SAM Or Navigator Pro 9335 Only)
Reference section 5, System Installation, of Style 9335 Navigator Pro With Pressure, Flow CAFS
And Valve Control Installation, Operating, And Maintenance Instructions (P/N 126914) found on
the flash drive provided with the system or on the Hale website (www.haleproducts.com).
Refer to Table 28 for a list of tools and/or consumables required for this procedure.
Table 28. Flowmeter Tools And Consumables List
Standard Tools
Special Tools
Consumables
PPE (Eye and Hand Protection)
None
Shop Rag(s) (As Required)
2-1/4-in Wrench
Cable Ties (As Required)
Loctite 243
Flowmeter
<See FSG-PL-01506, Sheet 1 & 2,
AKRON FLOW SENSOR>
Perform the following to replace a damaged flowmeter.
Removal
A.
Open SAM panel(s).
B.
Note cable tie locations, cut ONLY ties required to R&R flowmeter.
C.
At discharge valve motor controller, tag and disconnect wiring.
D.
Using a 2-1/4-in wrench, remove retaining nut. See Figure 47.
Figure 47. Flowmeter R&R
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...