64
NOTE
If the air bleed valve from the kit requires assembly, connect the check valve to the
straight thru port on the air bleed valve with the flow indicator (arrow) pointing away
from the air bleed valve and connect the adapter to the check valve output (output of
adapter goes to atmosphere), then connect the 90 degree elbow to the top center port
of the air bleed valve and the tubing to the input of the elbow as tagged. See
Figure 43. MIV–E Override Panel Air Bleed Valve Assembly
A.
Align placard with panel.
B.
Insert four [4] 8—32 x 0.75-in long pan head screws thru placard and panel.
C.
Install four [4] lock nuts at back of panel.
D.
Connect wire harness according to tags.
E.
Connect air bleed tubing according to tag.
F.
Install cable ties cut to R&R placard assembly as noted.
4.4.8
MIV Activation Button
A SAM MIV activation button (Figure 44) is also collocated with each MIV. Each MIV activation
placard houses an illuminated momentary contact pushbutton switch. The illuminated ring illumi-
nates solid green to indicate the associated master intake valve is closed and available, flashes
while the master intake valve is opening and then extinguishes when the valve is fully open.
Figure 44. Hale MIV Activation Button
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...