55
4.4.3
Buzzer
A SAM system provides a warning buzzer on the operators panel to notify the operator the SAM
Control Center (or SAM Pump Controller) requires attention. Table 10 provides the SAM system
from/to wire listing.
Table 10. Buzzer Wiring (From/To Listing)
From (Pin)
To
System Power (+12 VDC)
SAM Pump Controller, Connector A, Pin 22
Refer to Table 11 for a list of tools and/or consumables required for this procedure.
Table 11. Buzzer Tools And Consumables List
Standard Tools
Special Tools
Consumables
PPE (Eye and Hand Protection)
None
Cable Ties (As Required)
Wire Cutter
Buzzer
<See FSG-PL-01505, Sheet 1>
Slip Joint Plyers
(At Least 40 mm Jaw Opening)
If the buzzer fails to produce sound or is damaged; replace the buzzer as follows.
Removal
A.
Open SAM operator panel (or Officers side panel).
B.
Note cable tie locations, cut ONLY ties required to R&R buzzer.
C.
At rear of buzzer, tag and disconnect two [2] wires.
D.
Using slip joint plyers, remove retaining ring from front of buzzer. See Figure 36.
E.
Push buzzer thru panel and remove buzzer.
Figure 36. Buzzer R&R
Installation
A.
If applicable, remove two [2] screws.
B.
Discard screws.
C.
Using slip joint plyers, remove ring from front of new buzzer.
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...