background image

Motor Control

It is your responsibility to contact a qualified
electrician to assure that the electrical installation is
adequate and in conformance with all national and
local codes and ordinances.

Determine the correct overload setting required to
protect the motor (see motor starter manufacturer’s
recommendations). Select fuses, motor protective
switches or thermal protective switches to provide
protection. Fuses act as short circuit protection for the
motor, not as protection against overload. Incoming
line fuses help to withstand the motor’s starting current.
Motor starters with thermal magnetic overload or circuit
breakers protect motor from overload or reduced
voltage conditions.

The wiring diagram supplied with the product provides
required electrical information. Check that power
source is correct to properly operate the dual-voltage
motors.

Correct installation is your responsibility.

Make sure

you have the proper installation conditions and that
installation clearances do not block air flow. Proper
guards should be installed to prevent contact with
moveable parts of this pump. Do Not lift the unit by
the fan shroud.

INSTALLATION

Accessories

The product’s internal intake and exhaust filters will
provide adequate filtration in most applications. Check
filters periodically and replace when necessary. All
units should have an intake and exhaust filter to
prevent contaminants from entering the pump or the
pneumatic system. Please consult your Gast
Distributor/Representative for additional filter
recommendations.

Blocking air flow over the product in any way can
cause the product to overheat. Mounting

This product can be installed in any orientation.
Mounting the product to a stable, rigid operating
surface and using shock mounts will reduce noise and
vibration

Plumbing

Remove plugs from the IN and OUT ports. Connect
with pipe and fittings that are the same size or larger
than the product’s threaded ports.

Install relief valves and gauges at inlet or outlet, or
both, to monitor performance. Check valves may be
required to prevent back streaming through the pump.

2

Electrical Connection

Your safety and the safety of others

is extremely important.

We have provided many important safety messages in
this manual and on your product. Always read and
obey all safety messages.

This is the safety alert symbol. This symbol

alerts you to hazards that can kill or hurt you and
others. The safety alert symbol and the words
“ DANGER” and “ WARNING” will precede all safety
messages. These words mean:

You will be killed or seriously injured if you don’t follow
instructions.

You can be killed or seriously injured if you don’t follow
instructions.

WARNING

DANGER

Electrical Shock Hazard

Disconnect electrical power at the circuit breaker or
fuse box before installing this product.

Install this product where it will not come into
contact with water or other liquids.

Install this product where it will be weather
protected.

Electrically ground this product.

Failure to follow these instructions can result
in death, fire or electrical shock.

Summary of Contents for GAST 67 Series

Page 1: ...0 C 40 C Protect unit from dirt moisture Do not pump flammable or explosive gases or use in an atmosphere that contains such gases Protect all surrounding items from exhaust air This exhaust air can...

Page 2: ...the pneumatic system Please consult your Gast Distributor Representative for additional filter recommendations Blocking air flow over the product in any way can cause the product to overheat Mounting...

Page 3: ...4 2 2 It is your responsibility to operate this product at recommended pressures or vacuum duties and room ambient temperatures Do Not start against a vacuum or pressure load 3 OPERATION Injury Hazar...

Page 4: ...ot sound like it is running smoothly repeat steps 5 and 6 until you can hear a difference in the operating sound of the pump 8 Start the pump and let it run for 1 minute then turn pump off 9 Replace a...

Page 5: ...emove two fan coupling guard screws Remove guard 2 Remove four motor bolts Remove motor 3 Loosen two set screws in coupling flange Remove coupling flange from drive end shaft 4 Remove four screws from...

Page 6: ...e note current regulations Parts of the rotary vane pumps and compressors shafts iron or aluminum castings plastic or glass parts or bearings may be recycled as scrap materials Replacing New Body or R...

Page 7: ...or uses intended to be made of goods proposed changes or additions to goods or any assistance or suggestions that may have been made by Gast personnel Unauthorized extensions of warranties by the cus...

Page 8: ...et powder in pump Inspect and clean Motor not wired correctly Check wiring diagram and line voltage Running at too high an RPM Check wiring diagram and line voltage 8 PART NO 70 235 G365PL Rev H We ha...