Ambient conditions

/i

6.4

Noise level

/i

6.5

Safety classifications

/i

6.6

Electrical specifications

6.6.1

Power supply

/i

6.6.2

Dispenser

/i

Parameter

Specification

Metric standard

Imperial standard

Temperature [°C - °F]

+10 to +40

+50 to +104

Altitude above sea level, operational [m - ft]

-10 to 2000

-33 to 6562

Altitude above sea level, out of operation [m - ft]

-10 to 12000

-33 to 39370

Maximum Relative Humidity, without condensation 
[RH]

90%

Parameter

Specification

Maximum noise level [dB(A)]

< 65

Parameter

Specification

IP (Ingress Protection) classification

32

EMC (ElectroMagnetic Compatibility) classification

Class B

Parameter

Specification

Maximum power consumption [W]

85

Voltage [V AC]

90~264

Voltage [Hz]

50 / 60

Maximum leakage current [mA]

3.5

AC inlet

IEC320/C14

Parameter

Specification

Maximum power consumption [W]

75

Voltage [V DC]

24

Technical data 

X-Smart

V 1.4

Summary of Contents for Fast & Fluid X-SMART

Page 1: ...Original Manual X Smart www fluidman com V 1 4 www fast fluid com...

Page 2: ...f Fast Fluid Management B V to notify any person of such revision or change Details and values given in this manual are average values and have been compiled with care They are not binding however and...

Page 3: ...ription 9 3 1 1 Overview of the machine 9 3 1 2 Overview of the available optional parts 10 3 1 3 Type plate serial number 11 3 1 4 Type plate details 11 3 2 Operation 11 3 2 1 General dispensing proc...

Page 4: ...ooting guide 18 6 Technical data 19 6 1 General specifications 19 6 2 Dimensions and mass 19 6 3 Ambient conditions 20 6 4 Noise level 20 6 5 Safety classifications 20 6 6 Electrical specifications 20...

Page 5: ...structure and content 2 To read the safety chapter in detail and make sure you understand all the instructions See chapter 2 3 To carry out the actions completely and in the given sequence 1 2 Record...

Page 6: ...the instructions in this manual Connect the machine to a grounded wall socket Do not use extension cords or inadequately rated power cables Make sure that the power cable is freely accessible Do not...

Page 7: ...if you have written permission from the supplier of the machine 2 4 Certifications For some markets machines need a certification to proove the machine complies with the essential requirements concer...

Page 8: ...g 2 Do not dispose of the machine into domestic waste Dispose of the machine according to local regulations 3 Dispose of the canisters as chemical waste according to the local regulations Moving parts...

Page 9: ...w of the machine A Top cover B Canister C Pump D Slot for the can table E Nozzle F Can sensor G Can table H Emergency stop switch I Brush unit J Turntable K Agitator part of the stirring mechanism F G...

Page 10: ...10 3 1 2 Overview of the available optional parts A Monitor Keyboard arm B Wrap B A Operator manual X Smart V 1 4...

Page 11: ...ast fluid com www fluidman com INDEX India Pvt Ltd Survey no 256 GIDC Manjusar Savli Dist Vadodara 391 770 INDIA Model Serial No XXXXXX XX XXXX Prod Week XXXXXXXXX XXXXXX xx xx V xx W xx xx Hz X Wire...

Page 12: ...The correct height of the can table depends on the height of the can CAUTION Make sure that the can table is secure CAUTION Make sure that the can does not touch the turntable E Keep enough free spac...

Page 13: ...ce tasks and a reminder to keep your machine in optimal condition Replace the brush unit C every 4 months for optimal performance Use the X Smart paper funnels D for the clean filling and refilling of...

Page 14: ...with a click connection It is advised to replace the brush unit every 4 months to ensure optimal performance Replacement brush units are provided in the X Smart Maintenance Kit 1 Slide the brush unit...

Page 15: ...liquids in the brush container Note Do not exceed the maximum filling height F Note The optimum fluid level depends on the type of colorant that is used A B Note The brush unit is properly connected t...

Page 16: ...e colorant CAUTION Make sure that the colorant level in the canister is correct If a canister is empty it can cause an inaccurate dispensing and or a recipe fault Note The dispense software checks the...

Page 17: ...ut of the pumps See 4 3 4 3 Flushing the air out of the pump 1 Flush the air out of the pump Use the air flushing command in the dispense software If the dispense software does have an air flushing co...

Page 18: ...nt Europe and Asia or www fluidman com Fluid management U S A 5 3 Troubleshooting guide Note For all error messages on the computer see the help topic in the dispense software Problem Possible cause P...

Page 19: ...l oz 0 077 0 0026 Nozzle diameter mm in 4 0 517 Parameter Specification Metric standard Imperial standard Dimensions height x width x depth cm in 125 x 83 x 95 49 2 x 32 7 x 37 4 Packed dimensions hei...

Page 20: ...level out of operation m ft 10 to 12000 33 to 39370 Maximum Relative Humidity without condensation RH 90 Parameter Specification Maximum noise level dB A 65 Parameter Specification IP Ingress Protecti...

Page 21: ...e 17 4 2014 2 02 NvB NvB NvB 21 1 2013 2 0 3 4 2013 2 01 2 02 Revnr Sheet Title Date Drawn Remarks Filename FAST FLUID Version The Netherlands 2170 AE Sassenheim PO Box 220 Hub v Doorneweg 31 Fast FLu...

Page 22: ...Manufactured by IDEX India Pvt Ltd Survey no 256 GIDC Manjusar Savli Dist Vadodara 391 770 India 22...

Reviews: